Analysis of fast kV-switching in dual energy CT using a pre-reconstruction decomposition technique - art. no. 691313

被引:80
作者
Zou, Yu [1 ]
Silver, Michael D. [1 ]
机构
[1] Toshiba Med Res Inst USA, Vernon Hills, IL 60061 USA
来源
MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3 | 2008年 / 6913卷
关键词
computed tomography; dual energy;
D O I
10.1117/12.772826
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fast W-switching is a dual energy acquisition technique in CT in which alternating views correspond to the low and high tube voltages. Its high temporal resolution and its suitability to a variety of source trajectories make it an attractive option for dual energy data acquisition. Its disadvantages include a one view mis-registration between the data for high and low voltages, the potential for poor spectrum separation because the fast W-switching waveform may be more like a sine wave than the desired square wave, and the higher noise in the low voltage data because of the technical difficulty of swinging the tube current to counter the loss of x-ray production efficiency and loss of penetration at lower tube voltages. These issues are investigated with a recently developed pre-reconstruction decomposition method by the authors. Results include that symmetric view matching eliminates streaks from the view mis-registration, a sinusoidal waveform swinging between 80 and 135 kV gives sufficient spectrum separation, and that contrast-to-noise for the simulated imaging task maximizes at monochromatic energy of 75 keV.
引用
收藏
页码:91313 / 91313
页数:12
相关论文
共 14 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]   THE 3 PARAMETER EQUIVALENT SPECTRA AS AN INDEX OF BEAM QUALITY [J].
BOONE, JM .
MEDICAL PHYSICS, 1988, 15 (03) :304-310
[3]   COMPARISON OF 4 DUAL ENERGY IMAGE DECOMPOSITION METHODS [J].
CHUANG, KS ;
HUANG, HK .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (04) :455-466
[4]  
FAUL D D, 1982, Journal of Computer Assisted Tomography, V6, P202, DOI 10.1097/00004728-198202000-00049
[5]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[6]  
HASEGAWA BH, 1993, IEEE T NUCL SCI, V40, P1212
[7]  
HOUNSFIELD GN, 1973, CLASSIC PAPERS MODER
[8]   Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[9]  
SOSNA J, 2007, RSNA 2007 CHIC IL
[10]  
WALTER DJ, 1942, P SPIE, V6142