Electrochemical oxidation of meloxicam and its determination in tablet dosage form

被引:41
作者
Radi, A [1 ]
El Ries, MA
El-Anwar, F
El-Sherif, Z
机构
[1] Mansoura Univ, Dept Chem, Fac Sci, Dumyat 34517, Egypt
[2] Natl Org Drug Control & Res, Cairo, Egypt
关键词
meloxicam; linear-scan voltammetry; formulation analysis;
D O I
10.1081/AL-100103216
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The oxidative voltammetric behavior of meloxicam at a carbon paste electrode has been studied in Britton-Robinson buffers in the pH range of 2.0-11.5. Meloxicam gave rise to two voltammetric peaks, corresponding to the oxidation of amide and enol functions, respectively. The oxidation process was found to be dependent on the pH of the supporting electrolyte. Using linear-scan voltammetry, the drug yielded well-defined voltammetric response in; Britton-Robinson buffer of pH 3.0. The process could be used to determine meloxicam concentration in the range 5:0 x 10(-7) - 5 x 10(-5) M with detection limit of 1.6 x 10(-7) M. Application of the method to the determination of the drug in the dosage form, without any interference from the excipients, resulted in acceptable deviation from the stated concentration (RSD = 2.2 %).
引用
收藏
页码:739 / 748
页数:10
相关论文
共 11 条
[1]   Stability-indicating method for the determination of meloxicam and tetracaine hydrochloride in the presence of their degradation products [J].
Bebawy, LI .
SPECTROSCOPY LETTERS, 1998, 31 (04) :797-820
[2]  
BROOKS MA, 1984, LABORATORY TECHNIQUE, P569
[3]   Clinical pharmacokinetics of meloxicam - A cyclo-oxygenase-2 preferential nonsteroidal anti-inflammatory drug [J].
Davies, NM ;
Skjodt, NM .
CLINICAL PHARMACOKINETICS, 1999, 36 (02) :115-126
[4]   ELECTROOXIDATION AND DETERMINATION OF THE ANTIINFLAMMATORY DRUGS PIROXICAM AND TENOXICAM AT THE CARBON PASTE ELECTRODE [J].
ELMAALI, NA ;
HASSAN, RM .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1990, 24 (02) :155-163
[5]  
FOGG AG, 1994, ANAL PROC, V31, P1
[6]  
Joselyn L, 1999, NEW ELECTRON, V32, P10
[7]   Simultaneous high performance liquid chromatographic analysis of non-steroidal anti-inflammatory oxicams in pharmaceutical preparations [J].
Joseph-Charles, J ;
Bertucat, M .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1999, 22 (13) :2009-2021
[8]   SENSORS BASED ON CARBON-PASTE IN ELECTROCHEMICAL ANALYSIS - A REVIEW WITH PARTICULAR EMPHASIS ON THE PERIOD 1990-1993 [J].
KALCHER, K ;
KAUFFMANN, JM ;
WANG, J ;
SVANCARA, I ;
VYTRAS, K ;
NEUHOLD, C ;
YANG, Z .
ELECTROANALYSIS, 1995, 7 (01) :5-22
[9]   VOLTAMMETRIC STUDY OF THE DIURETIC XIPAMIDE [J].
LEGORBURU, MJ ;
ALONSO, RM ;
JIMENEZ, RM .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1993, 32 (01) :57-66
[10]   Structure and physicochemical properties of meloxicam, a new NSAID [J].
Luger, P ;
Daneck, K ;
Engel, W ;
Trummlitz, G ;
Wagner, K .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 1996, 4 (03) :175-187