Determination of firing distance. Lead analysis on the target by atomic absorption spectroscopy (AAS)

被引:27
作者
Gagliano-Candela, Roberto [1 ]
Colucci, Anna P. [1 ]
Napoli, Salvatore [2 ]
机构
[1] Univ Bari, Dipartimento Med Interna & Med Pubbl, Lab Tossicol Forense, I-70124 Bari, Italy
[2] Univ Bari, Dept Internal Med & Publ Hlth, I-70121 Bari, Italy
关键词
forensic sciences; firing distance; lead residues analysis; gunshot residues pattern; atomic absorption spectroscopy;
D O I
10.1111/j.1556-4029.2008.00668.x
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
This paper reports a method for the determination of the firing distance. Atomic absorption spectroscopy (AAS) was used to determine the lead (Pb) pattern around bullet holes produced by shots on test targets from the gun. Test shots were made with a Colt 38 Special at 5, 10, 20, 25, 30, 35, 40, 45, 50, 60, 80, and 100 cm target distance. The target was created with sheets of Whatman no. 1 paper on a polystyrene support. The target was subdivided into three carefully cut out rings (1, 2, and 3; with external diameters of 1.4 cm; 5 cm; 10.2 cm, respectively). Each sample was analyzed with graphite furnace AAS. Lead values analysis performed for each ring yielded a linear relation between the firing distance (cm) and the logarithm of lead amounts (mu g/cm(2)) in definite target areas (areas 2 + 3): [ln dPb(2+3) = a(0) + a(1)l]; where dPb(2+3) = lead mu g/cm(2) of area 2 + 3; a(0) and a(1) are experimentally calculated; l = distance in cm.
引用
收藏
页码:321 / 324
页数:4
相关论文
共 10 条
[1]  
Barnes F. C., 1974, J FORENSIC SCI, V19, P448
[2]  
BERGMAN P, 1984, FIRING DISTANCE DETE
[3]   DETERMINATION OF FIRING DISTANCE AND FIRING ANGLE BY NEUTRON-ACTIVATION ANALYSIS IN A CASE INVOLVING GUNSHOT WOUNDS [J].
CAPANNESI, G ;
CIAVOLA, C ;
SEDDA, AF .
FORENSIC SCIENCE INTERNATIONAL, 1993, 61 (2-3) :75-84
[4]  
EVEN H, 1988, J FORENSIC SCI, V33, P319
[5]  
GAGLIANOCANDELA R, 1979, RIV ITAL MED LEG, V1, P303
[6]  
Krishnan SS, 1967, J FORENSIC SCI, V12, P471
[7]  
Krishnan SS, 1974, J FORENSIC SCI, V19, P351
[8]   Identification of gunshot residue: a critical review [J].
Romolo, FS ;
Margot, P .
FORENSIC SCIENCE INTERNATIONAL, 2001, 119 (02) :195-211
[9]  
Saferstein R., 1982, FORENSIC SCI HDB
[10]  
Spiegel M. R., 1994, STATISTICA