Application of online voltage mismatch condition monitoring of induction motor stator windings in a mining environment

被引:0
作者
Sottile, J [1 ]
Trutt, FC [1 ]
Kohler, JL [1 ]
机构
[1] Univ Kentucky, Lexington, KY 40506 USA
来源
2003 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-3: CROSSROADS TO INNOVATIONS | 2003年
关键词
induction motor; condition monitoring;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Previous theoretical and laboratory research has demonstrated the utility of using voltage mismatch predictors for online condition monitoring of induction motor stator windings. However, the use of this monitoring system in a mining or other industry application depends upon the ability to determine motor impedance parameters prior to the onset of winding deterioration. Since these impedance parameters depend upon the motor speed, such evaluations require the collection of voltage and current data over a range of operating speeds. In addition, a sufficient amount of natural or created voltage unbalance is required in order to evaluate these parameters. The investigation presented in this paper uses duplicate data-collection and evaluation setups in both an operating mine and in the laboratory in order to obtain a better understanding of the voltage variations that are required for determination of the motor impedance parameters. Results are then related to the feasibility of applying voltage mismatch condition-monitoring procedures in an operating mine.
引用
收藏
页码:1637 / 1644
页数:8
相关论文
共 15 条
[1]  
ARKAN M, 1999, 34 IEEE IND APPL SOC, P1908
[2]   Inter-turn stator winding fault diagnosis in three-phase induction motors, by Park's vector approach [J].
Cardoso, AJM ;
Cruz, SMA ;
Fonseca, DSB .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (03) :595-598
[3]  
Cash MA, 1998, IEEE IND APPLIC SOC, P299, DOI 10.1109/IAS.1998.732310
[4]  
Cash MA, 1997, IEEE IND APPLIC SOC, P208, DOI 10.1109/IAS.1997.643029
[5]  
Kliman GB, 1996, IEEE IND APPLIC SOC, P687, DOI 10.1109/IAS.1996.557113
[6]   Condition monitoring of stator windings in induction motors: Part I - Experimental investigation of the effective negative-sequence impedance detector [J].
Kohler, JL ;
Sottile, J ;
Trutt, FC .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2002, 38 (05) :1447-1453
[7]  
Nasar S. A., 1999, ELECT POWER SYSTEMS
[8]   DETECTION AND LOCATION OF INTERTURN SHORT CIRCUITS IN THE STATOR WINDINGS OF OPERATING MOTORS [J].
PENMAN, J ;
SEDDING, HG ;
LLOYD, BA ;
FINK, WT .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1994, 9 (04) :652-658
[9]   A new method of current-based condition monitoring in induction machines operating under arbitrary load conditions [J].
Schoen, RR ;
Habetler, TG .
ELECTRIC MACHINES AND POWER SYSTEMS, 1997, 25 (02) :141-152
[10]   Condition monitoring of stator windings in induction motors: Part II - Experimental investigation of voltage mismatch detectors [J].
Sottile, J ;
Trutt, FC ;
Kohler, JL .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2002, 38 (05) :1454-1459