Chloride-induced corrosion of a galvanized steel-embedded calcium sulfoaluminate stucco system

被引:24
作者
Sereewatthanawut, Issara [1 ]
Pansuk, Withit [2 ]
Pheinsusom, Phoonsak [2 ]
Prasittisopin, Lapyote [3 ]
机构
[1] Pathumthani Univ, Fac Engn & Technol, 40 Rangsit Pathum Thani Rd, Pathum Thani 12000, Thailand
[2] Chulalongkorn Univ, Fac Engn, Dept Civil Engn, Innovat Construct Mat Res Unit, Phayathai Rd, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Fac Architecture, Dept Architecture, Phayathai Rd, Bangkok 10330, Thailand
关键词
Corrosion; Service life; Calcium sulfoaluminate cement; Chloride; Galvanized steel reinforcement; REINFORCING STEEL; PORTLAND-CEMENT; CONCRETE; PENETRATION; BEHAVIOR;
D O I
10.1016/j.jobe.2021.103376
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The study of steel corrosion in steel-reinforced cementitious system has attracted much attention because this system is used in key buildings and infrastructure, and, thus, its deterioration represents a significant hazard. In many constructions, the top cement surface is coated with a stucco system. In this study, we present experimental results on the corrosion behavior of a rapid-set stucco composite consisting of calcium sulfoaluminate cement (CSA). The rapid-set stucco is a new product on the market and was designed to improve the practicality of stucco use, which typically requires three coatings. Our test results indicate that the structure is not influenced by the fine aggregate (FA) content but is affected by the water-to-cement (w/c) ratio. The w/c ratio affects the apparent diffusivity (D-a) of chloride ions penetrating the structure. The pH results indicate that the passivation layer is not formed, leaving a doubt that the CSA stucco should be in use, especially for non-galvanized steel reinforced system. To reduce the negative effect of absence of passivation layer, uniform mixing and casting mixture having good workability is needed which can prolong its serviceability up to 3 times. The use of galvanized steel is also essential which can be increase its service life for at least 5 to 10 times. This is because zinc layer from galvanization process also greatly decreases the corrosion rate by 475% less than that of steel layer itself.
引用
收藏
页数:13
相关论文
共 57 条
[1]   Investigation of the mechanical and durability properties of sustainable high performance concrete based on calcium sulfoaluminate cement [J].
Afroughsabet, Vahid ;
Biolzi, Luigi ;
Monteiro, Paulo J. M. ;
Gastaldi, Matteo M. .
JOURNAL OF BUILDING ENGINEERING, 2021, 43
[2]  
Andrade C, 2004, Galvanized steel reinforcement in concrete, P111, DOI [10.1016/B978- 008044511-3/50020-7, DOI 10.1016/B978-008044511-3/50020-7]
[3]  
[Anonymous], 2012, C1152C1552M04 ASTM A
[4]  
[Anonymous], 2014, INT S CEM MAT NUCL W
[5]  
[Anonymous], 2009, C84709 ASTM ASTM INT
[6]  
[Anonymous], 2013, G10907 ASTM ASTM INT
[7]  
[Anonymous], 2009, C192C192M18 ASTM AST
[8]  
[Anonymous], 2016, C155611A ASTM ASTM I
[9]  
[Anonymous], 2018, C14418 ASTM ASTM INT
[10]  
[Anonymous], 2013, C19113 ASTM ASTM INT