Flow diverters for treatment of intracranial aneurysms: Current status and ongoing clinical trials

被引:115
作者
Wong, George K. C. [1 ]
Kwan, Marco C. L. [1 ]
Ng, Rebecca Y. T. [1 ]
Yu, Simon C. H. [2 ]
Poon, W. S. [1 ]
机构
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Div Neurosurg, Dept Surg, Shatin, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Imaging & Intervent Radiol, Shatin, Hong Kong, Peoples R China
关键词
Aneurysm; Flow diverter; Intracranial hemorrhage; Stent; Stroke; Subarachnoid hemorrhage; PIPELINE EMBOLIZATION DEVICE; STENT PLACEMENT; ENDOVASCULAR RECONSTRUCTION; DISRUPTING DEVICE; NEUROFORM STENT; ARTERY ANEURYSM; HEMODYNAMICS; EXPERIENCE; THROMBOSIS; PATENCY;
D O I
10.1016/j.jocn.2010.10.011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The ultimate treatment goal for intracranial aneurysms is to reconstruct the vessel wall and correct the hemodynamic disturbance. A flow diverter is a stent placed in the parent artery to reduce blood flow in the aneurysm sac to the point of stagnation, gradual thrombosis, and neointimal remodeling to maintain outflow in the side branches and perforators. Here, we review the two commercially available flow diverters, the Pipeline Embolization Device (PED) and the SILK flow diverter (SFD). The rates of severe hemorrhagic complications have been reported to be 2% for the PED and 0.8% for the SFD. The results of studies completed thus far show that endovascular reconstruction with flow diverters is an effective treatment of wide-necked, fusiform, large, and giant unruptured intracranial aneurysms, with 5% to 10% of patients experiencing permanent major morbidity and mortality. The results of ongoing studies may resolve whether flow diverters can replace coil embolization for the treatment of all, or selected, intracranial aneurysms. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:737 / 740
页数:4
相关论文
共 36 条
  • [21] Effects of stent porosity on hemodynamics in a sidewall aneurysm model
    Liou, Tong-Miin
    Li, Yi-Chen
    [J]. JOURNAL OF BIOMECHANICS, 2008, 41 (06) : 1174 - 1183
  • [22] CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICE: THE BUENOS AIRES EXPERIENCE
    Lylyk, Pedro
    Miranda, Carlos
    Ceratto, Rosana
    Ferrario, Angel
    Scrivano, Esteban
    Luna, Hugh Ramirez
    Berez, Aaron L.
    Tran, Quang
    Nelson, Peter K.
    Fiorella, David
    [J]. NEUROSURGERY, 2009, 64 (04) : 632 - 642
  • [23] Masuo O, 2005, AM J NEURORADIOL, V26, P543
  • [24] Masuo O, 2002, AM J NEURORADIOL, V23, P706
  • [25] International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial
    Molyneux, A
    Kerr, R
    Stratton, I
    Sandercock, P
    Clarke, M
    Shrimpton, J
    Holman, R
    [J]. LANCET, 2002, 360 (9342) : 1267 - 1274
  • [26] Reproducibility of haemodynamical simulations in a subject-specific stented aneurysm model -: A report on the Virtual Intracranial Stenting Challenge 2007
    Radaellia, A. G.
    Augsburger, L.
    Cebral, J. R.
    Ohta, M.
    Ruefenacht, D. A.
    Balossino, R.
    Benndorf, G.
    Hose, D. R.
    Marzo, A.
    Metcalfe, R.
    Mortier, P.
    Mut, F.
    Reymond, P.
    Socci, L.
    Verhegghe, B.
    Frangi, A. F.
    [J]. JOURNAL OF BIOMECHANICS, 2008, 41 (10) : 2069 - 2081
  • [27] An Original Flow Diversion Device for the Treatment of Intracranial Aneurysms Evaluation in the Rabbit Elastase-Induced Model
    Sadasivan, Chander
    Cesar, Liliana
    Seong, Jaehoon
    Rakian, Audrey
    Hao, Qing
    Tio, Fermin O.
    Wakhloo, Ajay K.
    Lieber, Baruch B.
    [J]. STROKE, 2009, 40 (03) : 952 - 958
  • [28] Treatment of Intracranial Aneurysms by Functional Reconstruction of the Parent Artery: The Budapest Experience with the Pipeline Embolization Device
    Szikora, I.
    Berentei, Z.
    Kulcsar, Z.
    Marosfoi, M.
    Vajda, Z. S.
    Lee, W.
    Berez, A.
    Nelson, P. K.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (06) : 1139 - 1147
  • [29] SZIKORA I, 2010, 2 ESMINT C SEPT 10 N
  • [30] Alteration of intraaneurysmal hemodynamics by placement of a self-expandable stent Laboratory investigation
    Tateshima, Satoshi
    Tanishita, Kazuo
    Hakata, Yasuhiro
    Tanoue, Shin-Ya
    Vinuela, Fernando
    [J]. JOURNAL OF NEUROSURGERY, 2009, 111 (01) : 22 - 27