A comparative study of the energy resolution achievable with digital signal processors in X-ray spectroscopy

被引:18
作者
Geraci, A
Zambusi, M
Ripamonti, G
机构
[1] Politecnico di Milano, Dipartimento di Elettronica e Informazione, Milano
关键词
D O I
10.1109/23.491523
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Interest for digital processing of signals from radiation detectors Is subject to a growing attention due to its intrinsic adaptivity, easiness of calibration, etc, This work compares two digital processing methods: a multiple-delay-line (DL)(N) filter and a least-mean-squares (LMS) adaptive filter for applications in high resolution X-ray spectroscopy, The signal pulse, as appears at the output of a proper analog conditioning circuit, is digitized: the samples undergo a digital filtering procedure, Both digital filters take advantage of the possibility of synthesizing the best possible weighting function with respect to the actual noise conditions, A noticeable improvement of more than 10% in energy resolution has been achieved with both systems with respect to state-of-the-art systems based on analog circuitry. In particular, the two digital processors are shown to be the best choice respectively: for on-line use with critical ballistic deficit conditions and for very-high-resolution spectroscopy systems, ultimately limited by 1/f noise.
引用
收藏
页码:731 / 736
页数:6
相关论文
共 15 条
[1]   SAMPLING AND OPTIMUM DATA-PROCESSING OF DETECTOR SIGNALS [J].
BERTUCCIO, G ;
GATTI, E ;
SAMPIETRO, M ;
REHAK, P ;
RESCIA, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (02) :271-279
[2]   A NOVEL CHARGE SENSITIVE PREAMPLIFIER WITHOUT THE FEEDBACK RESISTOR [J].
BERTUCCIO, G ;
REHAK, P ;
XI, DM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) :71-76
[3]   AN OPTIMUM DIGITAL SIGNAL-PROCESSING FOR RADIATION SPECTROSCOPY [J].
BERTUCCIO, G ;
FAZZI, A ;
GERACI, A ;
SAMPIETRO, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :257-260
[4]   OPTIMUM FILTERS FOR DETECTOR CHARGE MEASUREMENTS IN PRESENCE OF 1/F NOISE [J].
GATTI, E ;
SAMPIETRO, M ;
MANFREDI, PF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 287 (03) :513-520
[5]   SUBOPTIMAL FILTERING OF 1/F-NOISE IN DETECTOR CHARGE MEASUREMENTS [J].
GATTI, E ;
MANFREDI, PF ;
SAMPIETRO, M ;
SPEZIALI, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (03) :467-478
[6]  
GATTI E, 1985, NUCL INSTRUM METH A, V235, P224
[7]  
GATTI E, 1986, NUOVO CIMENTO, V9, P38
[8]   DIGITAL PULSE PROCESSING IN HIGH-RESOLUTION, HIGH-THROUGHPUT GAMMA-RAY SPECTROSCOPY [J].
GEORGIEV, A ;
GAST, W .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :770-779
[9]  
HADDAD RA, 1991, DIGIT SIGNAL PROCESS, pCH6
[10]  
KNOLL GF, 1974, RAD DETECTION MEASUR, pCH17