Reliability of human serum protein profiles generated with C8 magnetic beads assisted MALDI-TOF mass spectrometry

被引:76
作者
de Noo, ME
Tollenaar, RAEM
Özalp, A
Kuppen, PJK
Bladergroen, MR
Eilers, PHC
Deelder, AM
机构
[1] Leiden Univ, Med Ctr, Dept Surg, Biomol Mass Spectrometry Unit,Dept Parasitol, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Med State & Bioinformat, NL-2300 RC Leiden, Netherlands
关键词
D O I
10.1021/ac050571f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Protein profiling with mass spectrometry is a promising approach for classification and identification of biomarkers; however, there is debate about measurement quality and reliability. Here, we present a pipeline for preprocessing, statistical data analysis and presentation. Serum samples of 16 healthy individuals are used to generate protein profiles with high-resolution MALDI-TOF after isolation of peptides with C8 magnetic beads. Analysis of variance was performed after binning, baseline correction and normalization of the mean spectra. Relative variations in the spectra are expressed as coefficient of variation, which depending on the respective preanalytical variation parameter investigated, was found to range between 0. 15 and 0.67 in this study. With this novel method, the reproducibility of our protein profiling procedure could be quantified. We showed that circadian rhythm and the number of freeze-thaw cycles had relatively limited influence on serum protein profiles, whereas the period between collection and serum centrifugation had a more pronounced effect.
引用
收藏
页码:7232 / 7241
页数:10
相关论文
共 28 条
  • [1] Adam BL, 2002, CANCER RES, V62, P3609
  • [2] Ion suppression in mass spectrometry
    Annesley, TM
    [J]. CLINICAL CHEMISTRY, 2003, 49 (07) : 1041 - 1044
  • [3] Reproducibility of SELDI-TOF protein patterns in serum: comparing datasets from different experiments
    Baggerly, KA
    Morris, JS
    Coombes, KR
    [J]. BIOINFORMATICS, 2004, 20 (05) : 777 - U710
  • [4] Standardized approach to proteome profiling of human serum based on magnetic bead separation and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Baumann, S
    Ceglarek, U
    Fiedler, GM
    Lembcke, J
    Leichtle, A
    Thiery, J
    [J]. CLINICAL CHEMISTRY, 2005, 51 (06) : 973 - 980
  • [5] Biomedical informatics for proteomics
    Boguski, MS
    McIntosh, MW
    [J]. NATURE, 2003, 422 (6928) : 233 - 237
  • [6] Small molecule analysis by MALDI mass spectrometry
    Cohen, LH
    Gusev, AI
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (07) : 571 - 586
  • [7] Quality control and peak finding for proteomics data collected from nipple aspirate fluid by surface-enhanced laser desorption and ionization
    Coombes, KR
    Fritsche, HA
    Clarke, C
    Chen, JN
    Baggerly, KA
    Morris, JS
    Xiao, LC
    Hung, MC
    Kuerer, HM
    [J]. CLINICAL CHEMISTRY, 2003, 49 (10) : 1615 - 1623
  • [8] Parametric time warping
    Eilers, PHC
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (02) : 404 - 411
  • [9] A perfect smoother
    Eilers, PHC
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (14) : 3631 - 3636
  • [10] PROTEINS UNDER EXTREME PHYSICAL CONDITIONS
    JAENICKE, R
    ZAVODSZKY, P
    [J]. FEBS LETTERS, 1990, 268 (02): : 344 - 349