Dynamic volume vs respiratory correlated 4DCT for motion assessment in radiation therapy simulation

被引:26
作者
Coolens, Catherine [1 ,2 ]
Bracken, John [1 ]
Driscoll, Brandon [1 ]
Hope, Andrew [1 ,2 ]
Jaffray, David [1 ,2 ,3 ]
机构
[1] Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5S 3S2, Canada
[3] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 2M9, Canada
关键词
motion; computed tomography; radiation therapy; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; LUNG-CANCER PATIENTS; TUMOR MOTION; CT SCANS; RADIOTHERAPY; VARIABILITY; ARTIFACTS; QUALITY;
D O I
10.1118/1.4704498
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Conventional (i.e., respiratory-correlated) 4DCT exploits the repetitive nature of breathing to provide an estimate of motion; however, it has limitations due to binning artifacts and irregular breathing in actual patient breathing patterns. The aim of this work was to evaluate the accuracy and image quality of a dynamic volume, CT approach (4D(vol)) using a 320-slice CT scanner to minimize these limitations, wherein entire image volumes are acquired dynamically without couch movement. This will be compared to the conventional respiratory-correlated 4DCT approach (RCCT). Methods: 4D(vol) CT was performed and characterized on an in-house, programmable respiratory motion phantom containing multiple geometric and morphological "tumor" objects over a range of regular and irregular patient breathing traces obtained from 3D fluoroscopy and compared to RCCT. The accuracy of volumetric capture and breathing displacement were evaluated and compared with the ground truth values and with the results reported using RCCT. A motion model was investigated to validate the number of motion samples needed to obtain accurate motion probability density functions (PDF). The impact of 4D image quality on this accuracy was then investigated. Dose measurements using volumetric and conventional scan techniques were also performed and compared. Results: Both conventional and dynamic volume 4DCT methods were capable of estimating the programmed displacement of sinusoidal motion, but patient breathing is known to not be regular, and obvious differences were seen for realistic, irregular motion. The mean RCCT amplitude error averaged at 4 mm (max. 7.8 mm) whereas the 4D(vol) CT error stayed below 0.5 mm. Similarly, the average absolute volume error was lower with 4D(vol) CT. Under irregular breathing, the 4D(vol) CT method provides a close description of the motion PDF (cross-correlation 0.99) and is able to track each object, whereas the RCCT method results in a significantly different PDF from the ground truth, especially for smaller tumors (cross-correlation ranging between 0.04 and 0.69). For the protocols studied, the dose measurements were higher in the 4D(vol) CT method (40%), but it was shown that significant mAs reductions can be achieved by a factor of 4-5 while maintaining image quality and accuracy. Conclusions: 4D(vol) CT using a scanner with a large cone-angle is a promising alternative for improving the accuracy with which respiration-induced motion can be characterized, particularly for patients with irregular breathing motion. This approach also generates 4DCT image data with a reduced total scan time compared to a RCCT scan, without the need for image binning or external respiration signals within the 16 cm scan length. Scan dose can be made comparable to RCCT by optimization of the scan parameters. In addition, it provides the possibility of measuring breathing motion for more than one breathing cycle to assess stability and obtain a more accurate motion PDF, which is currently not feasible with the conventional RCCT approach. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4704498]
引用
收藏
页码:2669 / 2681
页数:13
相关论文
共 29 条
  • [1] [Anonymous], 111 AAPM TASK GROUP
  • [2] Artifacts in CT: Recognition and avoidance
    Barrett, JF
    Keat, N
    [J]. RADIOGRAPHICS, 2004, 24 (06) : 1679 - 1691
  • [3] An "in silico" clinical trial comparing free breathing, slow and respiration correlated computed tomography in lung cancer patients
    Bosmans, Geert
    Buijsen, Jeroen
    Dekker, Andre
    Velders, Marije
    Boersma, Liesbeth
    De Ruysscher, Dirk
    Minken, Andre
    Lambin, Philippe
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 (01) : 73 - 80
  • [4] Implementation and characterization of a 320-slice volumetric CT scanner for simulation in radiation oncology
    Coolens, C.
    Breen, S.
    Purdie, T. G.
    Owrangi, A.
    Publicover, J.
    Bartolac, S.
    Jaffray, D. A.
    [J]. MEDICAL PHYSICS, 2009, 36 (11) : 5120 - 5127
  • [5] A margin model to account for respiration-induced tumour motion and its variability
    Coolens, Catherine
    Webb, Steve
    Shirato, H.
    Nishioka, K.
    Evans, Phil M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (16) : 4317 - 4330
  • [6] The susceptibility of IMRT dose distributions to intrafraction organ motion: An investigation into smoothing filters derived from four dimensional computed tomography data
    Coolens, Catherine
    Evans, Phil M.
    Seco, Joao
    Webb, Steve
    Blackall, Jane M.
    Rietzel, Eike
    Chen, George T. Y.
    [J]. MEDICAL PHYSICS, 2006, 33 (08) : 2809 - 2818
  • [7] American Association of Physicists in Medicine radiation therapy committee task group 53: Quality assurance for clinical radiotherapy treatment planning
    Fraass, B
    Doppke, K
    Hunt, M
    Kutcher, G
    Starkschall, G
    Stern, R
    Van Dyke, J
    [J]. MEDICAL PHYSICS, 1998, 25 (10) : 1773 - 1829
  • [8] Computed tomography dose assessment for a 160 mm wide, 320 detector row, cone beam CT scanner
    Geleijns, J.
    Artells, M. Salvado
    Bruin, P. Wde
    Matter, R.
    Muramatsu, Y.
    McNitt-Gray, M. F.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (10) : 3141 - 3159
  • [9] The correlation between internal and external markers for abdominal tumors: Implications for respiratory gating
    Gierga, DP
    Brewer, J
    Sharp, GC
    Betke, M
    Willett, CG
    Chen, GTY
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (05): : 1551 - 1558
  • [10] 4-dimensional computed tomography imaging and treatment planning
    Keall, P
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) : 81 - 90