An Improved Scheme of Active Power Differential Protection for Transmission Line

被引:0
|
作者
He, Yangyang [1 ]
Zheng, Xiaodong [1 ]
Tai, Nengling [1 ]
Gao, Houlei [2 ]
Huang, Wentao [1 ]
Nadeem, M. Haroon [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai, Peoples R China
[2] Shandong Univ, Jinan, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Active power differential protection; auxiliary criteria; restraint characteristic criteria; transmission line; voltage dead zone;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, an improved scheme of active power differential protection for transmission line is proposed. The criteria for active power differential protection are optimally designed and described in detail. Restraint characteristic criteria and additional auxiliary criteria are used to solve the "voltage dead zone" issues of active power differential protection. Simulation results show that the proposed protection scheme can accurately identify the fault area without dead zone when metallic ground fault occurs near the protection units. In addition, active power differential protection has the advantage of low data synchronization requirements, and it is verified in this study.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Study on a new differential protection for transmission line
    Yuan, Rongxiang
    Chen, Deshu
    Zhang, Zhe
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2000, 20 (04): : 9 - 13
  • [32] Discussion on Differential Lightning Protection of Transmission Line
    Wang Qinghao
    Zhang Lei
    Li Guangda
    Li Tianci
    Zang Han
    Hu Yue
    Liu Lin
    Wang Qi
    Guo Yan
    Liu Xiao
    Liu Guobin
    2019 4TH INTERNATIONAL WORKSHOP ON MATERIALS ENGINEERING AND COMPUTER SCIENCES (IWMECS 2019), 2019, : 498 - 504
  • [33] Differential Evolution Based Special Protection and Control Scheme for Contingency Monitoring of Transmission Line Overloading
    Hadi, Mahmood Khalid
    Othman, Mohammad Lutfi
    Abd Wahab, Noor Izzri
    RECENT TRENDS IN INFORMATION AND COMMUNICATION TECHNOLOGY, 2018, 5 : 475 - 487
  • [34] Kullback-Leibler divergence based differential protection scheme for shunt compensated transmission line
    Biswal, Sandeep
    Tajdinian, Mohsen
    Adly, Ahmed R.
    Patidar, Ram Dayal
    Bhoi, Akash Kumar
    Rathore, Natwar Singh
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2021, 15 (12) : 1808 - 1819
  • [35] Self-adaptive differential protection scheme for transmission line based on Hausdorff distance algorithm
    Li Y.
    Wu Z.
    Wang F.
    Zeng G.
    Chen Z.
    Luo Y.
    Zhu X.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (07): : 175 - 180and187
  • [36] A novel current differential protection scheme for transmission lines using fast active current extraction
    Deng, Xiangtian
    Yuan, Rongxiang
    Xiao, Zhenfeng
    International Journal of Control and Automation, 2014, 7 (07): : 131 - 144
  • [37] An Integrated Protection Scheme for Power Line Systems
    Bo, Z. Q.
    Klimke, A.
    He, J. H.
    Dong, X. Z.
    Zhang, B. H.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 4286 - 4291
  • [38] A New Adaptive Distance Protection Scheme for a Transmission Line
    Ma, Jing
    Yan, Xin
    Ma, Wei
    Sun, Lvyi
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (01) : 1 - 17
  • [39] Modified Transmission Line Protection Scheme in the Presence of SCC
    Naeini, Ehsan Mostaghimi
    Vaseghi, Behrouz
    Mahdavian, Mehdi
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2017, 12 (02) : 533 - 540
  • [40] A Protection Scheme of Transmission Line Based on Nature Frequency
    Wang, X. G.
    Huang, S. F.
    2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 79 - 83