X-ray-sensitive hybrid photon detectors with Be-windows

被引:2
|
作者
D'Ambrosio, C [1 ]
De Notaristefani, F
Leutz, H
Puertolas, D
Rosso, E
机构
[1] CERN, CH-1211 Geneva, Switzerland
[2] Ist Nazl Fis Nucl, Sez Roma, Rome, Italy
关键词
29.30 spectroscopic techniques; 29.40 radiation detectors; 85.60.11; photodetectors; hybrid photon detectors; YAP(Ce);
D O I
10.1109/TNS.2005.850489
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A 0.3-mm thin YAlO3 (Ce) scintillating crystal plate of 22 mm diameter was mounted inside an electrostatic-focussed hybrid photomultiplier tube (HPMT). The photocathode was evaporated directly on this scintillating plate opposite to the HPMT-anode. The HPMT was vacuum-sealed with a 1-mm thick Be radiation entrance window. Photoelectron numbers at their peak energies of photoabsorption and energy resolutions were measured between 3.69 and 59.6 keV. The average number of photoelectrons produced per keV radiation energy was determined to be 4.457 phel/keV and the energy resolution at 59.6 keV was 17%. Introducing in the same way such a thin YAlO3 (Ce) plate inside an imaging silicon pixel array (ISPA) tube would improve its spatial resolution, since it depends on the thickness of the X-ray detector.
引用
收藏
页码:729 / 735
页数:7
相关论文
共 50 条
  • [1] HIGH-SPEED ULTRAVIOLET AND X-RAY-SENSITIVE INP PHOTOCONDUCTIVE DETECTORS
    DEUTSCH, TF
    LEONBERGER, FJ
    FOYT, AG
    MILLS, D
    APPLIED PHYSICS LETTERS, 1982, 41 (05) : 403 - 405
  • [2] X-RAY-SENSITIVE ALTERNATING COPOLYMERS
    TURNER, SR
    ANDERSON, CC
    KOLTERMAN, KM
    SELIGSON, D
    ACS SYMPOSIUM SERIES, 1989, 381 : 172 - 191
  • [3] Preliminary Studies on X-Ray-sensitive Liposome
    MENG Fan-xu 1
    2.Key Lab of Organic Optoelectronics and Molecular Engineering
    Chemical Research in Chinese Universities, 2012, 28 (02) : 319 - 322
  • [4] Preliminary Studies on X-Ray-sensitive Liposome
    Meng Fan-xu
    Xu Hua-ping
    Qi Yan-fei
    Xu Kun
    Song Xiu-ling
    Niu Shu
    Li Juan
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2012, 28 (02) : 319 - 322
  • [5] A LARGE-AREA X-RAY-SENSITIVE VIDICON
    LUHTA, RF
    ROWLANDS, JA
    RADIOLOGY, 1992, 185 : 201 - 201
  • [6] X-RAY-SENSITIVE FIBEROPTIC INTENSIFIER SCREEN FOR TOPOGRAPHY
    SMITH, RW
    RCA REVIEW, 1975, 36 (03): : 632 - 637
  • [7] GENE RECOMBINATION IN X-RAY-SENSITIVE CHO CELLS
    HAMILTON, A
    THACKER, J
    BRITISH JOURNAL OF CANCER, 1986, 54 (02) : 356 - 356
  • [8] A detector based on an X-ray-sensitive CCD array
    Krasnjuk, AA
    Stenin, VY
    Sherhalov, DS
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1999, 42 (05) : 637 - 639
  • [9] Evaluation of the reusability of an X-ray-sensitive phosphor screen
    Kinsella, T
    Neary, M
    Bartels, K
    Light, G
    43RD INTERNATIONAL SAMPE SYMPOSIUM AND EXHIBITION ON MATERIALS AND PROCESS AFFORDABILITY - KEYS TO THE FUTURE, VOL 43, 1998, : 1487 - 1498
  • [10] ELECTRON AND X-RAY-SENSITIVE RESISTS IN MODERN MICROELECTRONICS
    SELIVANOV, GK
    MOZZHUKHIN, DD
    GRIBOV, BG
    SOVIET MICROELECTRONICS, 1980, 9 (06): : 282 - 297