Fluorescent peptide-based sensors for the ratiometric detection of nanomolar concentration of heparin in aqueous solutions and in serum

被引:24
|
作者
Thirupathi, Ponnaboina [1 ]
Neupane, Lok Nath [1 ]
Lee, Keun-Hyeung [1 ]
机构
[1] Inha Univ, Dept Chem & Chem Engn, Ctr Design & Applicat Mol Catalysts, Bioorgan Chem Lab, Inchon 402751, South Korea
基金
新加坡国家研究基金会;
关键词
Fluorescence; Peptide; Biosensor; Chemosensor; Ratiometric; Heparin; PARTIAL THROMBOPLASTIN TIME; MOLECULAR-WEIGHT HEPARIN; TRANSITION-METAL IONS; TURN-ON DETECTION; INDUCED THROMBOCYTOPENIA; ELECTROCHEMICAL SENSOR; SELECTIVE DETECTION; ASSAY; PROBE; CHEMOSENSORS;
D O I
10.1016/j.aca.2015.03.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New fluorescent peptide-based sensors (1-3) for monitoring heparin in serum sample were synthesized using short peptides (1 similar to 3mer) as a receptor. The peptide-based sensors (2 and 3) showed a sensitive ratiometric response to heparin both in aqueous buffered solution (10 mM HEPES, pH 7.4) and in 2% human serum sample by increase of excimer emission of pyrene at 480 nm and concomitant decrease of monomer emission of pyrene at 376 nm, whereas the peptide-based sensor 1 showed a turn off response only by decrease of monomer emission at 376 nm. 2 and 3 exhibited excellent selectivity toward heparin among various anions and competitors of heparin including chondroitin 4-sulfate (ChS) and hyaluronic acid (HA). Peptide-based sensor 3 showed a more sensitive response to heparin than 2. The detection limit of 3 was determined as 36 pM (R-2 = 0.998) for heparin in aqueous solution and 204 pM (R-2 = 0.999) for heparin in aqueous solutions containing 2% human serum. The peptide-based sensors, 2 and 3 provided a practical and potential tool for the detection and quantification of heparin in real biological samples. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:88 / 98
页数:11
相关论文
共 50 条
  • [1] Ratiometric Detection of Nanomolar Concentrations of Heparin in Serum and Plasma Samples Using a Fluorescent Chemosensor Based on Peptides
    Kim, Da-Hye
    Park, Yu Jin
    Jung, Kwan Ho
    Lee, Keun-Hyeung
    ANALYTICAL CHEMISTRY, 2014, 86 (13) : 6580 - 6586
  • [2] Ratiometric fluorescent detection of heparan sulfate in human plasma and serum using peptide-based fluorescent probes
    Subedi, Sumita
    Khadka, Kishor
    Park, Myeong-geun
    Jeon, Inae
    Cho, Moodong
    Lee, Keun-Hyeung
    MICROCHEMICAL JOURNAL, 2025, 212
  • [3] A peptide-based fluorescent ratiometric sensor for quantitative detection of proteins
    Choulier, Laurence
    Shvadchak, Volodymyr V.
    Naidoo, Aletia
    Klymchenko, Andrey S.
    Mely, Yves
    Altschuh, Daniele
    ANALYTICAL BIOCHEMISTRY, 2010, 401 (02) : 188 - 195
  • [4] Development of peptide-based ratiometric fluorescent probe for sensing heparan sulfate and heparin in aqueous solutions at physiological pH and quantitative detection of heparan sulfate in live cells
    Subedi, Sumita
    Hwang, Hyun Jung
    Kang, Donghee
    Mehta, Pramod Kumar
    Kim, Nayeon
    Park, Hyojin
    Lee, Jae-Seon
    Lee, Keun-Hyeung
    BIOSENSORS & BIOELECTRONICS, 2023, 238
  • [5] Fluorescent Peptide Beacons for the Selective Ratiometric Detection of Heparin
    Maity, Debabrata
    Schmuck, Carsten
    CHEMISTRY-A EUROPEAN JOURNAL, 2016, 22 (37) : 13156 - 13161
  • [6] A pyrene-based fluorescent sensor for ratiometric detection of heparin and its complex with heparin for reversed ratiometric detection of protamine in aqueous solution
    Gong, Weiwei
    Wang, Shihuai
    Wei, Yuting
    Ding, Liping
    Fang, Yu
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2017, 170 : 198 - 205
  • [7] Ratiometric fluorescent detection of lead ions in aquatic environment and living cells using a fluorescent peptide-based probe
    Mehta, Pramod Kumar
    Jeon, Jongyong
    Ryu, Ki
    Park, See-Hyoung
    Lee, Keun-Hyeung
    JOURNAL OF HAZARDOUS MATERIALS, 2022, 427
  • [8] A peptide-based fluorescent chemosensor for multianalyte detection
    Wang, Peng
    Liu, Lixuan
    Zhou, Panpan
    Wu, Wenyu
    Wu, Jiang
    Liu, Weisheng
    Tang, Yu
    BIOSENSORS & BIOELECTRONICS, 2015, 72 : 80 - 86
  • [9] A peptide-based fluorescent chemosensor for measuring cadmium ions in aqueous solutions and live cells
    Wang, Peng
    Wu, Jiang
    Liu, Lixuan
    Zhou, Panpan
    Ge, Yushu
    Liu, Dan
    Liu, Weisheng
    Tang, Yu
    DALTON TRANSACTIONS, 2015, 44 (41) : 18057 - 18064
  • [10] Ratiometric fluorescent detection of silver nanoparticles in aqueous samples using peptide-based fluorogenic probes with aggregation-induced emission characteristics
    Mehta, Pramod Kumar
    Neupane, Lok Nath
    Park, See-Hyoung
    Lee, Keun-Hyeung
    JOURNAL OF HAZARDOUS MATERIALS, 2021, 411