Radiologist variability in assessing the position of the cavoatrial junction on chest radiographs

被引:19
作者
Chan, Tze Y. [1 ]
England, Andrew [2 ]
Meredith, Sara M. [1 ]
McWilliams, Richard G. [1 ]
机构
[1] Royal Liverpool Univ Hosp NHS Trust, Dept Radiol, Liverpool, Merseyside, England
[2] Univ Salford, Directorate Radiog, Manchester, Lancs, England
关键词
INSERTED CENTRAL CATHETERS; CENTRAL VENOUS CATHETERS; TIP POSITION; AGREEMENT; SYSTEM;
D O I
10.1259/bjr.20150965
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To assess the variability in identifying the cavoatrial junction (CAJ) on chest X-rays (CXRs) amongst radiologists. Methods: 23 radiologists (13 consultants and 10 trainees) assessed 25 posteroanterior erect CXRs (including 8 duplicates) and marked the positions of the CAJ. Differences in the CAJ position both within and between observers were evaluated and reported as limits of agreement (LOA), repeatability coefficients (RCs) and intraclass correlation coefficients and were displayed graphically with Bland-Altman plots. Results: The mean difference for within-observer assessments was -0.2cm (95% LOA, -1.5 to +1.1 cm) and between observers, it was -0.3cm (95% LOA, -2.5 to +1.8 cm). Intraobserver RCs were marginally lower for consultants than for trainees (1.1 vs 1.5). RCs between observers were comparable (2.1 vs 2.2) for consultants and trainees, respectively. Conclusion: This study detected a large interobserver variability of the CAJ position (up to 4.3 cm). This is a significant finding considering that the length of the superior vena cava is reported to be approximately 7 cm. We conclude that there is poor consensus regarding the CAJ position amongst radiologists. Advances in knowledge: No comparisons exist between radiologists in determining CAJ position from CXRs. This report provides evidence of the large observer variability amongst radiologists and adds to the discussion regarding the use of CXRs in validating catheter tip location systems.
引用
收藏
页数:8
相关论文
共 32 条
[1]   Imaging of the complications of peripherally inserted central venous catheters [J].
Amerasekera, S. S. H. ;
Jones, C. M. ;
Patel, R. ;
Cleasby, M. J. .
CLINICAL RADIOLOGY, 2009, 64 (08) :832-840
[2]  
[Anonymous], 2005, CLARKS POSITIONING R
[3]  
[Anonymous], 1982, PROC SPIE, DOI DOI 10.1117/12.967674
[4]  
[Anonymous], INTRO MED IMAGING
[5]  
[Anonymous], PERIPHERALLY INSERTE
[6]   MRI of central venous anatomy - Implications for central venous catheter insertion [J].
Aslamy, Z ;
Dewald, CL ;
Heffner, JE .
CHEST, 1998, 114 (03) :820-826
[7]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[8]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[9]  
Cardella J F, 1993, J Vasc Interv Radiol, V4, P653, DOI 10.1016/S1051-0443(93)71941-7
[10]   CARDIAC-TAMPONADE FROM CENTRAL VENOUS CATHETERS REPORT OF A CASE AND REVIEW OF THE ENGLISH-LITERATURE [J].
COLLIER, PE ;
RYAN, JJ ;
DIAMOND, DL .
ANGIOLOGY, 1984, 35 (09) :595-600