Single-sweep pulmonary vein isolation using the new third-generation laser balloon-Evolution in ablation style using endoscopic ablation system

被引:7
作者
Tohoku, Shota [1 ]
Bordignon, Stefano [1 ]
Chen, Shaojie [1 ,2 ]
Zanchi, Simone [1 ]
Bianchini, Lorenzo [1 ]
Trolese, Luca [3 ]
Operhalski, Felix [4 ]
Urbanek, Lukas [1 ]
Chun, K. R. Julian [1 ,2 ]
Schmidt, Boris [1 ,4 ]
机构
[1] Cardioangiol Ctr Bethanien, Wilhelm Epstein Str 4, D-60431 Frankfurt, Germany
[2] Univ Lubeck, Die Sekt Med, Lubeck, Germany
[3] Univ Herzzentrum Freiburg Bad Krozingen, Klin Kardiol & Angiol 1, Freiburg, Germany
[4] Univ Klinikum Frankfurt, Med Klin 3, Klin Kardiol, Frankfurt, Germany
关键词
atrial fibrillation; balloon ablation; endoscopic ablation system; laser balloon; pulmonary vein isolation; RADIOFREQUENCY ABLATION; CRYOBALLOON;
D O I
10.1111/jce.15245
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The endoscopic ablation system (EAS) is an established ablation device for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). The novel X3 EAS is now equipped with a contiguous circumferential ablation mode (RAPID mode). Aim To determine the feasibility of single-shot fashioned ablation using X3. Methods Consecutive patients who underwent AF ablation using X3 were enrolled. We assessed the acute procedural data focusing on "Single-sweep PVI" defined as successful PVI with a single RAPID mode energy application, and on "first-pass isolation" defined as successful PVI after initial circular lesion set. Results One hundred AF patients (56% male, age: 68 +/- 10 years, 66% paroxysmal AF) were analyzed. A total of 379 of 383 PVs (99%) were isolated with X3. Single-sweep PVI and first-pass-isolation were achieved in 214 PVs (56%) and in 362 PVs (95%), respectively. Single-sweep PVI rates varied across PVs with higher rates at the superior PVs (61.2% vs. inferior PVs: 49.5%, p = .0239) and at PVs with maximal ostial diameter <24 mm (57.6% vs. >24 mm: 36.8%, p = .0151). The mean total procedure and fluoroscopy times were 43.0 +/- 10 and 4.0 +/- 2 min, respectively. In none of the patients an acute thromboembolic event (stroke or transient ischemic attack) or a pericardial effusion/tamponade occurred. A single transient phrenic nerve palsy was observed. Conclusion The new X3 EAS allows for single-shot fashioned ablation in terms of single-sweep PVI in half or more of PVs. The new RAPID ablation mode leads to an improved rate of first-pass isolation associated with very short procedure times without compromising safety.
引用
收藏
页码:2923 / 2932
页数:10
相关论文
共 50 条
  • [41] Single-ring ablation compared with standard circumferential pulmonary vein isolation using remote magnetic catheter navigation
    Christian Sohns
    Leonard Bergau
    Joachim Seegers
    Lars Lüthje
    Dirk Vollmann
    Markus Zabel
    Journal of Interventional Cardiac Electrophysiology, 2014, 41 : 75 - 82
  • [42] A frozen decade: Ten years outcome of atrial fibrillation ablation using a single shot device for pulmonary vein isolation
    Bergau, Leonard
    Sciacca, Vanessa
    Nesapiragasan, Vinitha
    Rubarth, Kerstin
    Konietschke, Frank
    Fink, Thomas
    El Hamriti, Mustapha
    Imnadze, Guram
    Dagher, Lilas
    Braun, Martin
    Khalaph, Moneeb
    Guckel, Denise
    Heintze, Johannes
    Noelker, Georg
    Vogt, Juergen
    Sommer, Philipp
    Sohns, Christian
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (07) : 1383 - 1390
  • [43] Single-ring ablation compared with standard circumferential pulmonary vein isolation using remote magnetic catheter navigation
    Sohns, Christian
    Bergau, Leonard
    Seegers, Joachim
    Luethje, Lars
    Vollmann, Dirk
    Zabel, Markus
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 41 (01) : 75 - 82
  • [44] High-Power Short-Duration Posterior Wall Isolation in Addition to Pulmonary Vein Isolation in Persistent Atrial Fibrillation Ablation Using the New TactiFlex™ Ablation Catheter
    Conti, Sergio
    Sabatino, Francesco
    Randazzo, Giulia
    Ferrara, Giuliano
    Cascino, Antonio
    Sgarito, Giuseppe
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2024, 11 (09)
  • [45] Single-center initial experience with a new pulsed-field ablation system: pulmonary vein isolation lesions and beyond
    Tsiachris, Dimitrios
    Antoniou, Christos-Konstantinos
    Doundoulakis, Ioannis
    Kordalis, Athanasios
    Stefanadis, Christodoulos
    Tsioufis, Konstantinos
    FUTURE CARDIOLOGY, 2024, 20 (14) : 739 - 746
  • [46] Prospective, Multicenter Study on the Incidence of New Embolic Cerebral Lesions following Pulmonary Vein Isolation Using Laserballoon Ablation
    Wissner, Erik
    Metzner, Andreas
    Neuzil, Petr
    Petru, Jan
    Vivek, Reddy
    Skoda, Jan
    Sediva, Lucia
    Schoonderwoerd, Bas
    Rausch, Peter
    Tilz, Roland R.
    Ouyang, Feifan
    Kuck, Karl-Heinz
    CIRCULATION, 2012, 126 (21)
  • [47] High-power short-duration ablation index–guided pulmonary vein isolation protocol using a single catheter
    Patrick Badertscher
    Sven Knecht
    Florian Spies
    Gian Völlmin
    Beat Schaer
    Nicolas Schärli
    Flurina Bosshard
    Stefan Osswald
    Christian Sticherling
    Michael Kühne
    Journal of Interventional Cardiac Electrophysiology, 2022, 65 : 633 - 642
  • [48] Cryoballoon Ablation for Pulmonary Vein Isolation in Patients With Persistent Atrial Fibrillation One-Year Outcome Using Second Generation Cryoballoon
    Koektuerk, Buelent
    Yorgun, Hikmet
    Hengeoez, Oezlem
    Turan, Cem H.
    Dahmen, Alina
    Yang, Alexander
    Bansmann, Paul M.
    Gorr, Eduard
    Hoppe, Christian
    Turan, Ramazan G.
    Horlitz, Marc
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (05) : 1073 - 1079
  • [49] Pulsed Field Ablation-Based Pulmonary Vein Isolation Using a Simplified Single-Access Single-Catheter Approach ― The Fast and Furious PFA Study ―
    Tilz, Roland R.
    Vogler, Julia
    Kirstein, Bettina
    Eitel, Charlotte
    Phan, Huong-Lan
    Popescu, Sorin Stefan
    Hatahet, Sascha
    Grosse, Niels
    Subin, Behnam
    Lopez, Lisbeth Delgado
    Kuck, Karl-Heinz
    Heeger, Christian-H.
    CIRCULATION JOURNAL, 2023, 87 (12) : 1722 - 1726
  • [50] Pulmonary vein isolation and left atrial catheter ablation using a three-dimensional navigation system for the treatment of atrial fibrillation
    Macle, Laurent
    Novak, Paul
    Khairy, Paul
    Thibault, Bernard
    Talajic, Mario
    Dubuc, Marc
    Roy, Denis
    Guerra, Peter G.
    CANADIAN JOURNAL OF CARDIOLOGY, 2009, 25 (06) : E169 - E172