Single-sweep pulmonary vein isolation using the new third-generation laser balloon-Evolution in ablation style using endoscopic ablation system

被引:7
作者
Tohoku, Shota [1 ]
Bordignon, Stefano [1 ]
Chen, Shaojie [1 ,2 ]
Zanchi, Simone [1 ]
Bianchini, Lorenzo [1 ]
Trolese, Luca [3 ]
Operhalski, Felix [4 ]
Urbanek, Lukas [1 ]
Chun, K. R. Julian [1 ,2 ]
Schmidt, Boris [1 ,4 ]
机构
[1] Cardioangiol Ctr Bethanien, Wilhelm Epstein Str 4, D-60431 Frankfurt, Germany
[2] Univ Lubeck, Die Sekt Med, Lubeck, Germany
[3] Univ Herzzentrum Freiburg Bad Krozingen, Klin Kardiol & Angiol 1, Freiburg, Germany
[4] Univ Klinikum Frankfurt, Med Klin 3, Klin Kardiol, Frankfurt, Germany
关键词
atrial fibrillation; balloon ablation; endoscopic ablation system; laser balloon; pulmonary vein isolation; RADIOFREQUENCY ABLATION; CRYOBALLOON;
D O I
10.1111/jce.15245
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The endoscopic ablation system (EAS) is an established ablation device for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). The novel X3 EAS is now equipped with a contiguous circumferential ablation mode (RAPID mode). Aim To determine the feasibility of single-shot fashioned ablation using X3. Methods Consecutive patients who underwent AF ablation using X3 were enrolled. We assessed the acute procedural data focusing on "Single-sweep PVI" defined as successful PVI with a single RAPID mode energy application, and on "first-pass isolation" defined as successful PVI after initial circular lesion set. Results One hundred AF patients (56% male, age: 68 +/- 10 years, 66% paroxysmal AF) were analyzed. A total of 379 of 383 PVs (99%) were isolated with X3. Single-sweep PVI and first-pass-isolation were achieved in 214 PVs (56%) and in 362 PVs (95%), respectively. Single-sweep PVI rates varied across PVs with higher rates at the superior PVs (61.2% vs. inferior PVs: 49.5%, p = .0239) and at PVs with maximal ostial diameter <24 mm (57.6% vs. >24 mm: 36.8%, p = .0151). The mean total procedure and fluoroscopy times were 43.0 +/- 10 and 4.0 +/- 2 min, respectively. In none of the patients an acute thromboembolic event (stroke or transient ischemic attack) or a pericardial effusion/tamponade occurred. A single transient phrenic nerve palsy was observed. Conclusion The new X3 EAS allows for single-shot fashioned ablation in terms of single-sweep PVI in half or more of PVs. The new RAPID ablation mode leads to an improved rate of first-pass isolation associated with very short procedure times without compromising safety.
引用
收藏
页码:2923 / 2932
页数:10
相关论文
共 50 条
  • [31] Significant reduction in procedure duration in remote magnetic-guided catheter ablation of atrial fibrillation using the third-generation magnetic navigation system
    Maurer, Tilman
    Sohns, Christian
    Deiss, Sebastian
    Rottner, Laura
    Wohlmuth, Peter
    Reissmann, Bruno
    Heeger, Christian H.
    Lemes, Christine
    Riedl, Johannes
    Santoro, Francesco
    Mathew, Shibu
    Metzner, Andreas
    Ouyang, Feifan
    Kuck, Karl-Heinz
    Wissner, Erik
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2017, 49 (03) : 219 - 226
  • [32] Fiberoptic balloon catheter ablation of pulmonary vein ostia in pigs using photonic energy delivery with diode laser
    Lemery, R
    Veinot, JP
    Tang, ASL
    Green, M
    Farr, N
    Baxter, L
    McIntyre, J
    Sinofsky, E
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (01): : 32 - 36
  • [33] Pulmonary vein isolation by duty-cycled bipolar and unipolar antrum ablation using a novel multielectrode ablation catheter system: first clinical results
    Marcus Wieczorek
    Reinhard Hoeltgen
    Martin Brueck
    Dirk Bandorski
    Elvan Akin
    Ali Reza Salili
    Journal of Interventional Cardiac Electrophysiology, 2010, 27 : 23 - 31
  • [34] Repeat pulmonary vein isolation and anterior line ablation using a novel point-by-point pulsed-field ablation system
    Wenzel, Jan-Per
    Lemoine, Marc D.
    Rottner, Laura
    My, Ilaria
    Moser, Fabian
    Obergassel, Julius
    Nies, Moritz
    Riess, Jan
    Ismaili, Djemail
    Nikorowitsch, Julius
    Ouyang, Feifan
    Kirchhof, Paulus
    Rillig, Andreas
    Metzner, Andreas
    Reissmann, Bruno
    HEART RHYTHM, 2024, 21 (03) : 250 - 257
  • [35] 5S Study: Safe and Simple Single Shot Pulmonary Vein Isolation With Pulsed Field Ablation Using Sedation
    Schmidt, Boris
    Bordignon, Stefano
    Tohoku, Shota
    Chen, Shaojie
    Bologna, Fabrizio
    Urbanek, Lukas
    Pansera, Francesco
    Ernst, Matthias
    Chun, K. R. Julian
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2022, 15 (06) : E010817
  • [36] Endothelial damage and thromboembolic risk after pulmonary vein isolation using the latest ablation technologies: a comparison of the second-generation cryoballoon vs. contact force-sensing radiofrequency ablation
    Hisazaki, Kaori
    Hasegawa, Kanae
    Kaseno, Kenichi
    Miyazaki, Shinsuke
    Amaya, Naoki
    Shiomi, Yuichiro
    Tama, Naoto
    Ikeda, Hiroyuki
    Fukuoka, Yoshitomo
    Morishita, Tetsuji
    Ishida, Kentaro
    Uzui, Hiroyasu
    Tada, Hiroshi
    HEART AND VESSELS, 2019, 34 (03) : 509 - 516
  • [37] Endothelial damage and thromboembolic risk after pulmonary vein isolation using the latest ablation technologies: a comparison of the second-generation cryoballoon vs. contact force-sensing radiofrequency ablation
    Kaori Hisazaki
    Kanae Hasegawa
    Kenichi Kaseno
    Shinsuke Miyazaki
    Naoki Amaya
    Yuichiro Shiomi
    Naoto Tama
    Hiroyuki Ikeda
    Yoshitomo Fukuoka
    Tetsuji Morishita
    Kentaro Ishida
    Hiroyasu Uzui
    Hiroshi Tada
    Heart and Vessels, 2019, 34 : 509 - 516
  • [38] Does second-generation cryoballoon ablation using the current single short freeze strategy produce pulmonary vein stenosis?
    Miyazaki, Shinsuke
    Kajiyama, Takatsugu
    Hada, Masahiro
    Nakamura, Hiroaki
    Hachiya, Hitoshi
    Tada, Hiroshi
    Hirao, Kenzo
    Lesaka, Yoshito
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 272 : 175 - 178
  • [39] High-power short-duration ablation index-guided pulmonary vein isolation protocol using a single catheter
    Badertscher, Patrick
    Knecht, Sven
    Spies, Florian
    Vollmin, Gian
    Schaer, Beat
    Scharli, Nicolas
    Bosshard, Flurina
    Osswald, Stefan
    Sticherling, Christian
    Kuhne, Michael
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 65 (03) : 633 - 642
  • [40] Significant reduction in procedure duration in remote magnetic-guided catheter ablation of atrial fibrillation using the third-generation magnetic navigation system
    Tilman Maurer
    Christian Sohns
    Sebastian Deiss
    Laura Rottner
    Peter Wohlmuth
    Bruno Reißmann
    Christian H. Heeger
    Christine Lemes
    Johannes Riedl
    Francesco Santoro
    Shibu Mathew
    Andreas Metzner
    Feifan Ouyang
    Karl-Heinz Kuck
    Erik Wissner
    Journal of Interventional Cardiac Electrophysiology, 2017, 49 : 219 - 226