Using a pulsed laser beam to investigate the feasibility of sub-pixel position resolution with time-correlated transient signals in 3D pixelated CdZnTe detectors

被引:5
|
作者
Giraldo, L. Ocampo [1 ,2 ]
Bolotnikov, A. E. [2 ]
Camarda, G. S. [2 ]
Cheng, S. [2 ]
De Geronimo, G. [2 ]
McGilloway, A. [2 ]
Fried, J. [2 ]
Hodges, D. [3 ]
Hossain, A. [2 ]
Unlu, K. [1 ]
Petryk, M. [2 ]
Vidal, V. [3 ]
Vernon, E. [2 ]
Yang, G. [2 ]
James, R. B. [4 ]
机构
[1] Penn State Univ, University Pk, PA 16802 USA
[2] Brookhaven Natl Lab, Upton, NY 11973 USA
[3] Univ Texas El Paso, El Paso, TX 79968 USA
[4] Savannah River Natl Lab, Aiken, SC USA
关键词
CdZnTe; High-granularity detectors; 3D pixelated detectors; Crystal defects; Charge sharing; Charge-loss correction; SPATIAL-RESOLUTION; CZT DETECTORS;
D O I
10.1016/j.nima.2017.04.030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We evaluated the X-Y position resolution achievable in 3D pixelated detectors by processing the signal waveforms readout from neighboring pixels. In these measurements we used a focused light beam, down to 10 mu m, generated by a similar to 1 mW pulsed laser (650 nm) to carry out raster scans over selected 3 x 3 pixel areas, while recording the charge signals from the 9 pixels and the cathode using two synchronized digital oscilloscopes. Published by Elsevier B.V.
引用
收藏
页码:7 / 14
页数:8
相关论文
共 8 条
  • [1] Study of sub-pixel position resolution with time-correlated transient signals in 3D pixelated CdZnTe detectors with varying pixel sizes
    Giraldo, L. Ocampo
    Bolotnikov, A. E.
    Camarda, B. G. S.
    De Geronimo, G.
    Fried, J.
    Gul, R.
    Hodges, D.
    Hossain, A.
    Unlu, K.
    Vernon, E.
    Yang, G.
    James, R. B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 884 : 136 - 139
  • [2] Achieving subpixel resolution with time-correlated transient signals in pixelated CdZnTe gamma-ray sensors using a focused laser beam
    Giraldo, Luis A. Ocampo
    Bolotnikov, Aleksey E.
    Camarda, Giuseppe S.
    Cui, Yonggang
    De Geronimo, Gianluigi
    Gul, Rubi
    Fried, Jack
    Hossain, Anwar
    Unlu, Kenan
    Vernon, Emerson
    Yang, Ge
    James, Ralph B.
    PHOTON COUNTING APPLICATIONS 2017, 2017, 10229
  • [3] Achieving sub-pixel position resolution and sub-millimeter depth resolution using a pixelated CdZnTe detector
    Wang, Chao
    Wei, Long
    Zhang, Zhiming
    Li, Daowu
    Feng, Baotong
    Liu, Yantao
    Xiang, Yu
    Li, Xin
    Jiang, Xiaopan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1033
  • [4] Sub-Pixel Position Sensing for Pixelated, 3-D Position Sensitive, Wide Band-Gap, Semiconductor, Gamma-Ray Detectors
    Zhu, Yuefeng
    Anderson, Stephen E.
    He, Zhong
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (03) : 1400 - 1409
  • [5] Laser Stripe Sub-Pixel Peak Detection in Real-Time 3D Scanning Using Power Modulation
    Besic, Ingmar
    Avdagic, Zikrija
    PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, : 951 - 956
  • [6] Laser Stripe Model for Sub-Pixel Peak Detection in Real-Time 3D Scanning
    Besic, Ingmar
    Avdagic, Zikrija
    2016 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2016, : 4332 - 4337
  • [7] High Resolution Time-Encoded Imaging of Plutonium and MOX using 3-D Position-Sensitive CdZnTe Detectors
    Goodman, David
    Xia, Jiawei
    Brown, Steven
    Chichester, David L.
    He, Zhong
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [8] Angular Detection and Shielding Characterization of Simulated 235U Using Time Encoded Imaging and 3D Position Sensitive CdZnTe Detectors
    Goodman, David
    Brown, Steven
    Chu, Jiyang
    He, Zhong
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,