How reliable are efficiency measurements of perovskite solar cells? The first inter-comparison, between two accredited and eight non-accredited laboratories

被引:68
作者
Dunbar, Ricky B. [1 ]
Duck, Benjamin C. [1 ]
Moriarty, Tom [2 ]
Anderson, Kenrick F. [1 ]
Duffy, Noel W. [3 ]
Fell, Christopher J. [1 ]
Kim, Jincheol [4 ]
Ho-Baillie, Anita [4 ]
Vak, Doojin [5 ]
The Duong [6 ]
Wu, YiLiang [6 ]
Weber, Klaus [6 ]
Pascoe, Alex [7 ]
Cheng, Yi-Bing [7 ]
Lin, Qiandian [8 ]
Burn, Paul L. [8 ]
Bhattacharjee, Ripon [9 ]
Wang, Hongxia [9 ]
Wilson, Gregory J. [1 ]
机构
[1] CSIRO Energy, Mayfield West, NSW 2304, Australia
[2] Natl Renewable Energy Lab, Golden, CO 80401 USA
[3] CSIRO Energy, Clayton, Vic 3800, Australia
[4] Univ New South Wales, Sch Photovolta & Renewable Energy Engn, ACAP, Sydney, NSW 2052, Australia
[5] CSIRO Mfg, Bag 10, Clayton, Vic 3168, Australia
[6] Australian Natl Univ, Res Sch Engn, Canberra, ACT 2601, Australia
[7] Monash Univ, Dept Mat Sci & Engn, Melbourne, Vic 3168, Australia
[8] Univ Queensland, Sch Chem & Mol Biosci, Ctr Organ Photon & Elect, Brisbane, Qld 4072, Australia
[9] Queensland Univ Technol, Sci & Engn Fac, Sch Chem Phys & Mech Engn, Brisbane, Qld, Australia
关键词
ORGANOMETAL TRIHALIDE PEROVSKITE; HOLE-CONDUCTOR-FREE; ANOMALOUS HYSTERESIS; ION MIGRATION; V HYSTERESIS; BEHAVIOR; ORIGIN; SLOW;
D O I
10.1039/c7ta05609e
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Perovskite materials have generated significant interest from academia and industry as a potential component in next-generation, high-efficiency, low-cost, photovoltaic (PV) devices. The record efficiency reported for perovskite solar cells has risen rapidly, and is now more than 22%. However, due to their complex dynamic behaviour, the process of measuring the efficiency of perovskite solar cells appears to be much more complicated than for other technologies. It has long been acknowledged that this is likely to greatly reduce the reliability of reported efficiency measurements, but the quantitative extent to which this occurs has not been determined. To investigate this, we conduct the first major inter-comparison of this PV technology. The participants included two labs accredited for PV performance measurement (CSIRO and NREL) and eight PV research laboratories. We find that the inter-laboratory measurement variability can be almost ten times larger for a slowly responding perovskite cell than for a control silicon cell. We show that for such a cell, the choice of measurement method, far more so than measurement hardware, is the single-greatest cause for this undesirably large variability. We provide recommendations for identifying the most appropriate method for a given cell, depending on its stabilisation and degradation behaviour. The results of this study suggest that identifying a consensus technique for accurate and meaningful efficiency measurements of perovskite solar cells will lead to an immediate improvement in reliability. This, in turn, should assist device researchers to correctly evaluate promising new materials and fabrication methods, and further boost the development of this technology.
引用
收藏
页码:22542 / 22558
页数:17
相关论文
共 47 条
  • [1] [Anonymous], 31 PHOT SPEC C
  • [2] [Anonymous], ADV MATER
  • [3] [Anonymous], 28 EUR PHOT SOL EN C
  • [4] [Anonymous], 10613 EUR EN
  • [5] Calibration procedure for solar cells exhibiting slow response and application to a dye-sensitized photovoltaic device
    Bardizza, Giorgio
    Pavanello, Diego
    Galleano, Roberto
    Sample, Tony
    Mullejans, Harald
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2017, 160 : 418 - 424
  • [6] Thermodynamic Origin of Photoinstability in the CH3NH3Pb(I1-xBrx)3 Hybrid Halide Perovskite Alloy
    Brivio, Federico
    Caetano, Clovis
    Walsh, Aron
    [J]. JOURNAL OF PHYSICAL CHEMISTRY LETTERS, 2016, 7 (06): : 1083 - 1087
  • [7] Evidence for ion migration in hybrid perovskite solar cells with minimal hysteresis
    Calado, Philip
    Telford, Andrew M.
    Bryant, Daniel
    Li, Xiaoe
    Nelson, Jenny
    O'Regan, Brian C.
    Barnes, Piers R. F.
    [J]. NATURE COMMUNICATIONS, 2016, 7
  • [8] Origin of J-V Hysteresis in Perovskite Solar Cells
    Chen, Bo
    Yang, Mengjin
    Priya, Shashank
    Zhu, Kai
    [J]. JOURNAL OF PHYSICAL CHEMISTRY LETTERS, 2016, 7 (05): : 905 - 917
  • [9] International round-robin inter-comparison of dye-sensitized and crystalline silicon solar cells
    Chen, Chia-Yuan
    Ahn, Seung Kyu
    Aoki, Dasiuke
    Kokubo, Junichi
    Yoon, Kyung Hoon
    Saito, Hidenori
    Lee, Kyung Sik
    Magaino, Shinichi
    Takagi, Katsuhiko
    Lin, Ling-Chuan
    Lee, Kun-Mu
    Wu, Chun-Guey
    Zhou, Hong
    Igari, Sanekazu
    [J]. JOURNAL OF POWER SOURCES, 2017, 340 : 309 - 318
  • [10] Best Practices in Perovskite Solar Cell Efficiency Measurements. Avoiding the Error of Making Bad Cells Look Good
    Christians, Jeffrey A.
    Manser, Joseph S.
    Kamat, Prashant V.
    [J]. JOURNAL OF PHYSICAL CHEMISTRY LETTERS, 2015, 6 (05): : 852 - 857