EM Measurements Between MV Switching Sources and Colocated Sensitive Circuit

被引:6
作者
Li, Peng [1 ]
Huang, Daochun [1 ]
Ruan, Jiangjun [1 ]
Niu, Xiaobo [1 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
关键词
Current transformer (CT); electromagnetic interference (EMI); feeder terminal unit (FTU); frequency distribution; pole-mounted switch; synthetic test; transient recovery voltage (TRV); wavelet analysis; TRANSIENT ELECTROMAGNETIC-FIELDS; WAVELET TRANSFORM; SUBSTATIONS; OVERVOLTAGES; OPERATIONS;
D O I
10.1109/TEMC.2015.2400230
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the development and increasing use of intelligent vacuum circuit breaker (VCB), the electromagnetic compatibility problem between VCBs and their low-voltage electronic equipment is becoming increasingly prominent. Switching operations of circuit breakers are known to be serious sources of electromagnetic interference (EMI) to their secondary equipment, which can lead to the control and protection devices display error and malfunction. Hence, it is very important to study the EMI problem of the secondary equipment (such as current transformer (CT), PT, and controller) caused by the operations of circuit breakers. This paper carried out the tests of a 10 kV medium-voltage outdoor pole-mounted switch by a synthetic test circuit with large current and high impulse voltage sources, and collected the current signals of the secondary circuit at the same time, then obtained the frequency and energy distributions of the disturbance signals, caused by the breaking operation of pole-mounted switch, by time and frequency characteristic analysis with the wavelet analysis. Results show that the secondary side of the CT and the feeder terminal unit (FTU) controller are bearing EMI when pole-mounted switch is in operation and the distribution of the frequency spectrum is wide. The most serious disturbance appears at the time of arc current passing zero and the frequency distribution is mainly in 7.81-15.63 MHz. The EMI caused by transient recovery voltage is mainly distribution in 31.25-125.0 MHz. The maximum amplitude of disturbance pulses is about 4.5 times as large as that of the normal case. The results can provide a reference to the measures against the EMI for the pole-mounted switch's FTU controller.
引用
收藏
页码:513 / 521
页数:9
相关论文
共 22 条
[1]   TRANSIENT ELECTROMAGNETIC-FIELDS DUE TO SWITCHING OPERATIONS IN ELECTRIC-POWER SYSTEMS [J].
ARI, N ;
BLUMER, W .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1987, 29 (03) :233-237
[2]  
Burger D., 2012, PROC INT S ELECTROMA, P1
[3]  
Burger D., 2011, P 10 INT S EL COMP Y, P597
[4]  
Chen L., 2007, THESIS SHANDONG U SH
[5]   Study of partial discharge measurement in power equipment using acoustic technique and wavelet transform [J].
Chen, Li-Jung ;
Lin, Whei-Min ;
Tsao, Ta-Peng ;
Lin, Yu-Hsun .
IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (03) :1575-1580
[6]   Compact Configuration for Common Mode Filter Design based on Planar Electromagnetic Bandgap Structures [J].
de Paulis, Francesco ;
Raimondo, Leo ;
Connor, Sam ;
Archambeault, Bruce ;
Orlandi, Antonio .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2012, 54 (03) :646-654
[7]   Overvoltages in secondary circuits of medium-voltage switchgear generated by multiple reignitions of circuit breakers [J].
Hardt, N ;
Koenig, D .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1999, 41 (04) :510-515
[8]   Impact of Switching-Induced Electromagnetic Interference on Low-Voltage Cables in Substations [J].
Heydari, Hossien ;
Abbasi, Vahid ;
Faghihi, Faramarz .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2009, 51 (04) :937-944
[9]  
Huang Yizhuang, 2008, POWER SYSTEM PROTECT, V36, P6
[10]   Magnetic Shielding Performance of Thin Metal Sheets Near Power Cables [J].
Kim, Sang-Beom ;
Soh, Joon-Young ;
Shin, Koo-Yong ;
Jeong, Jin-Hye ;
Myung, Sung-Ho .
IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (02) :682-685