Full Monte Carlo-Based Biologic Treatment Plan Optimization System for Intensity Modulated Carbon Ion Therapy on Graphics Processing Unit

被引:10
|
作者
Qin, Nan [1 ]
Shen, Chenyang [1 ]
Tsai, Min-Yu [1 ,2 ]
Pinto, Marco [3 ]
Tian, Zhen [1 ]
Dedes, Georgios [3 ]
Pompos, Arnold [1 ]
Jiang, Steve B. [1 ]
Parodi, Katia [3 ]
Jia, Xun [1 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Dept Radiat Oncol, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
[2] Natl Taiwan Univ, Dept Comp Sci & Informat Engn, Taipei, Taiwan
[3] Ludwig Maximilian Univ Munich, Dept Expt Phys Med Phys, Munich, Germany
基金
美国国家卫生研究院;
关键词
DOSE OPTIMIZATION; PROTON THERAPY; TRACK STRUCTURE; BEAM THERAPY; RADIOTHERAPY; RADIATION; MODEL; RBE; INACTIVATION; SIMULATIONS;
D O I
10.1016/j.ijrobp.2017.09.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: One of the major benefits of carbon ion therapy is enhanced biological effectiveness at the Bragg peak region. For intensity modulated carbon ion therapy (IMCT), it is desirable to use Monte Carlo (MC) methods to compute the properties of each pencil beam spot for treatment planning, because of their accuracy in modeling physics processes and estimating biological effects. We previously developed goCMC, a graphics processing unit (GPU)-oriented MC engine for carbon ion therapy. The purpose of the present study was to build a biological treatment plan optimization system using goCMC. Methods and Materials: The repair-misrepair-fixation model was implemented to compute the spatial distribution of linear-quadratic model parameters for each spot. A treatment plan optimization module was developed to minimize the difference between the prescribed and actual biological effect. We used a gradient-based algorithm to solve the optimization problem. The system was embedded in the Varian Eclipse treatment planning system under a client-server architecture to achieve a user-friendly planning environment. We tested the system with a 1-dimensional homogeneous water case and 3 3-dimensional patient cases. Results: Our system generated treatment plans with biological spread-out Bragg peaks covering the targeted regions and sparing critical structures. Using 4 NVidia GTX 1080 GPUs, the total computation time, including spot simulation, optimization, and final dose calculation, was 0.6 hour for the prostate case (8282 spots), 0.2 hour for the pancreas case (3795 spots), and 0.3 hour for the brain case (6724 spots). The computation time was dominated by MC spot simulation. Conclusions: We built a biological treatment plan optimization system for IMCT that performs simulations using a fast MC engine, goCMC. To the best of our knowledge, this is the first time that full MC-based IMCT inverse planning has been achieved in a clinically viable time frame. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:235 / 243
页数:9
相关论文
共 34 条
  • [21] Electron modulated arc therapy (EMAT) using photon MLC for postmastectomy chest wall treatment I: Monte Carlo-based dosimetric characterizations
    Ma, Chaoqiong
    Parsons, David
    Chen, Mingli
    Jiang, Steve
    Hou, Qing
    Gu, Xuejun
    Lu, Weiguo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 67 : 1 - 8
  • [22] Clinically Applicable Monte Carlo-based Biological Dose Optimization for the Treatment of Head and Neck Cancers With Spot-Scanning Proton Therapy
    Tseung, Hok Seum Wan Chan
    Ma, Jiasen
    Kreofsky, Cole R.
    Ma, Daniel J.
    Beltran, Chris
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (05): : 1535 - 1543
  • [23] A new approach to integrate GPU-based Monte Carlo simulation into inverse treatment plan optimization for proton therapy
    Li, Yongbao
    Tian, Zhen
    Song, Ting
    Wu, Zhaoxia
    Liu, Yaqiang
    Jiang, Steve
    Jia, Xun
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (01): : 289 - 305
  • [24] Intensity modulated proton therapy treatment planning using single-field optimization: The impact of monitor unit constraints on plan quality
    Zhu, X. R.
    Sahoo, N.
    Zhang, X.
    Robertson, D.
    Li, H.
    Choi, S.
    Lee, A. K.
    Gillin, M. T.
    MEDICAL PHYSICS, 2010, 37 (03) : 1210 - 1219
  • [25] Patient-specific bolus for range shifter air gap reduction in intensity-modulated proton therapy of head-and-neck cancer studied with Monte Carlo based plan optimization
    Michiels, Steven
    Barragan, Ana Maria
    Souris, Kevin
    Poels, Kenneth
    Crijns, Wouter
    Lee, John A.
    Sterpin, Edmond
    Nuyts, Sandra
    Haustermans, Karin
    Depuydt, Tom
    RADIOTHERAPY AND ONCOLOGY, 2018, 128 (01) : 161 - 166
  • [26] Increased organ sparing using shape-based treatment plan optimization for intensity modulated radiation therapy of pancreatic adenocarcinoma
    Petit, Steven F.
    Wu, Binbin
    Kazhdan, Michael
    Dekker, Andre
    Simari, Patricio
    Kumar, Rachit
    Taylor, Russel
    Herman, Joseph M.
    McNutt, Todd
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 (01) : 38 - 44
  • [27] Validation of robust radiobiological optimization algorithms based on the mixed beam model for intensity-modulated carbon-ion therapy
    Yagi, Masashi
    Tsubouchi, Toshiro
    Hamatani, Noriaki
    Takashina, Masaaki
    Saruwatari, Naoto
    Minami, Kazumasa
    Wakisaka, Yushi
    Fujitaka, Shinichiro
    Hirayama, Shusuke
    Nihongi, Hideaki
    Hasegawa, Azusa
    Koizumi, Masahiko
    Shimizu, Shinichi
    Ogawa, Kazuhiko
    Kanai, Tatsuaki
    PLOS ONE, 2023, 18 (07):
  • [28] Convergent Pencil Beam Modeling with Monte Carlo Transport Codes for Synchrotron Based Intensity Modulated Proton Beam System Model in Eclipse Treatment Planning System
    Moskvin, V.
    Zhao, L.
    Farr, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E266 - E267
  • [29] Monte Carlo-based inverse planning of modulated electron beam therapy using a few-leaf electron collimator provides highly conformal treatment and decreases whole body dose
    Alyahya, K
    Schwartz, M
    Patrocinio, H
    Parker, W
    Shenouda, G
    Verhaegen, F
    Freeman, C
    Seuntjens, J
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S16 - S16
  • [30] Monte Carlo simulations to support start-up and treatment planning of scanned proton and carbon ion therapy at a synchrotron-based facility
    Parodi, K.
    Mairani, A.
    Brons, S.
    Hasch, B. G.
    Sommerer, F.
    Naumann, J.
    Jaekel, O.
    Haberer, T.
    Debus, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (12): : 3759 - 3784