Breast ultrasound: automated or hand-held? Exploring patients' experience and preference

被引:12
|
作者
Mussetto, Ilaria [1 ]
Gristina, Licia [2 ]
Schiaffino, Simone [3 ]
Tosto, Simona [2 ]
Raviola, Edoardo [4 ]
Calabrese, Massimo [2 ]
机构
[1] Univ Genoa, Sch Radiol, Dept Hlth Sci DISSAL, Via Antonio Pastore 1, I-16132 Genoa, Italy
[2] IRCCS Policlin San Martino, Diagnost Senol, Largo Rosanna Benzi 10, I-16132 Genoa, Italy
[3] IRCCS Policlin San Donato, Radiol Unit, Via Morandi 30, I-20097 Milan, Italy
[4] Univ Vita Salute, Via Olgettina 58, I-20132 Milan, Italy
关键词
Anxiety; Fear; Pain; Personal satisfaction; Ultrasonography (mammary); MAMMOGRAPHY; CANCER; WOMEN; HHUS; ABUS;
D O I
10.1186/s41747-019-0136-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Our aim was to compare women's experience with automated breast ultrasound (ABUS) versus breast hand-held ultrasound (HHUS) and to evaluate their acceptance rate. Methods After ethical approval, from October 2017 to March 2018, 79 consecutive patients were enrolled in this prospective study. On the same day, patients underwent HHUS followed by ABUS. Each patient's experience was assessed using the modified testing morbidities index (TMI) (the lower the score, the better is the experience). Nine items were assessed for both techniques: seven directly related to the examination technique (pain or discomfort immediately before (preparation), during and after testing, fear or anxiety immediately before (preparation) and during testing, physical and mental function after testing) and two indirectly related to the examination technique (embarrassment during testing and overall satisfaction). Finally, we asked patients to choose between the two techniques for a potential next breast examination. Wilcoxon signed ranks test was used. Results The median TMI score for the seven items was found to be significantly better for HHUS (8, interquartile range [IQR] 7-11) compared to ABUS (9, IQR 8-12) (p = 0.003). The item 'pain/discomfort during the test' (p < 0.001) was significantly higher for ABUS compared to HHUS. Instead, the item 'fear/anxiety before the test' was higher for HHUS (p = 0.001). Overall, 40.5% of the patients chose HHUS, 29.1% chose ABUS, and 30.4% were unable to choose. Conclusions ABUS and HHUS exams were well tolerated and accepted. However, HHUS was perceived to be less painful than ABUS.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Automated coregistered imaging using a hand-held probe-based optical imager
    Regalado, Steven
    Erickson, Sarah J.
    Zhu, Banghe
    Ge, Jiajia
    Godavarty, Anuradha
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02)
  • [32] Accuracy of Wireless Hand-Held Guided Ultrasound Injections in the Trapeziometacarpal Joint: A Cadaveric Study
    Hamoudi, Ceyran
    Martins, Antoine
    Willaume, Thibault
    Debordes, Pierre-Antoine
    Liverneaux, Philippe
    Facca, Sybille
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (09)
  • [33] Clinical Utility of a Hand-Held Scanner for Breast Cancer Early Detection and Patient Triage
    Clanahan, Julie M.
    Reddy, Sanjana
    Broach, Robyn B.
    Rositch, Anne F.
    Anderson, Benjamin O.
    Wileyto, E. Paul
    Englander, Brian S.
    Brooks, Ari D.
    JCO GLOBAL ONCOLOGY, 2020, 6 : 27 - 34
  • [34] Three-dimensional fluorescence tomography of human breast tissues in vivo using a hand-held optical imager
    Erickson, Sarah J.
    Martinez, Sergio L.
    DeCerce, Joseph
    Romero, Adrian
    Caldera, Lizeth
    Godavarty, Anuradha
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (05) : 1563 - 1579
  • [35] Radiologist-performed hand-held ultrasound screening at average risk of breast cancer: results from a single health screening center
    Chang, Jung Min
    Koo, Hye Ryoung
    Moon, Woo Kyung
    ACTA RADIOLOGICA, 2015, 56 (06) : 652 - 658
  • [36] PRELIMINARY CLINICAL EXPERIENCE WITH A COMBINED AUTOMATED BREAST ULTRASOUND AND DIGITAL BREAST TOMOSYNTHESIS SYSTEM
    Larson, Eric D.
    Lee, Won-Mean
    Roubidoux, Marilyn A.
    Goodsitt, Mitchell M.
    Lashbrook, Chris
    Davis, Cynthia E.
    Kripfgans, Oliver D.
    Carson, Paul L.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (03) : 734 - 742
  • [37] Volumetric hand-held optoacoustic angiography as a tool for real-time screening of dense breast
    Dean-Ben, X. Luis
    Fehm, Thomas F.
    Gostic, Monika
    Razansky, Daniel
    JOURNAL OF BIOPHOTONICS, 2016, 9 (03) : 253 - 259
  • [38] Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results
    Golatta, Michael
    Franz, Dorothea
    Harcos, Aba
    Junkermann, Hans
    Rauch, Geraldine
    Scharf, Alexander
    Schuetz, Florian
    Sohn, Christof
    Heil, Joerg
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (08) : E332 - E336
  • [39] Investigating the feasibility of a hand-held photoacoustic imaging probe for margin assessment during breast conserving surgery
    Rascevska, E.
    Yip, L. C. M.
    Omidi, P.
    Brackstone, M.
    Carson, J. J. L.
    PHOTOACOUSTICS, 2022, 28
  • [40] Automated breast ultrasound (ABUS) as a screening tool: initial experience
    Amera Abd Elsalam Mostafa
    Mohamed Adel Eltomey
    Ashraf Mohammed Elaggan
    Amel A. Hashish
    Egyptian Journal of Radiology and Nuclear Medicine, 50