Breast ultrasound: automated or hand-held? Exploring patients' experience and preference

被引:12
|
作者
Mussetto, Ilaria [1 ]
Gristina, Licia [2 ]
Schiaffino, Simone [3 ]
Tosto, Simona [2 ]
Raviola, Edoardo [4 ]
Calabrese, Massimo [2 ]
机构
[1] Univ Genoa, Sch Radiol, Dept Hlth Sci DISSAL, Via Antonio Pastore 1, I-16132 Genoa, Italy
[2] IRCCS Policlin San Martino, Diagnost Senol, Largo Rosanna Benzi 10, I-16132 Genoa, Italy
[3] IRCCS Policlin San Donato, Radiol Unit, Via Morandi 30, I-20097 Milan, Italy
[4] Univ Vita Salute, Via Olgettina 58, I-20132 Milan, Italy
关键词
Anxiety; Fear; Pain; Personal satisfaction; Ultrasonography (mammary); MAMMOGRAPHY; CANCER; WOMEN; HHUS; ABUS;
D O I
10.1186/s41747-019-0136-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Our aim was to compare women's experience with automated breast ultrasound (ABUS) versus breast hand-held ultrasound (HHUS) and to evaluate their acceptance rate. Methods After ethical approval, from October 2017 to March 2018, 79 consecutive patients were enrolled in this prospective study. On the same day, patients underwent HHUS followed by ABUS. Each patient's experience was assessed using the modified testing morbidities index (TMI) (the lower the score, the better is the experience). Nine items were assessed for both techniques: seven directly related to the examination technique (pain or discomfort immediately before (preparation), during and after testing, fear or anxiety immediately before (preparation) and during testing, physical and mental function after testing) and two indirectly related to the examination technique (embarrassment during testing and overall satisfaction). Finally, we asked patients to choose between the two techniques for a potential next breast examination. Wilcoxon signed ranks test was used. Results The median TMI score for the seven items was found to be significantly better for HHUS (8, interquartile range [IQR] 7-11) compared to ABUS (9, IQR 8-12) (p = 0.003). The item 'pain/discomfort during the test' (p < 0.001) was significantly higher for ABUS compared to HHUS. Instead, the item 'fear/anxiety before the test' was higher for HHUS (p = 0.001). Overall, 40.5% of the patients chose HHUS, 29.1% chose ABUS, and 30.4% were unable to choose. Conclusions ABUS and HHUS exams were well tolerated and accepted. However, HHUS was perceived to be less painful than ABUS.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Breast ultrasound: automated or hand-held? Exploring patients’ experience and preference
    Ilaria Mussetto
    Licia Gristina
    Simone Schiaffino
    Simona Tosto
    Edoardo Raviola
    Massimo Calabrese
    European Radiology Experimental, 4
  • [2] Comparison of Automated Breast Ultrasound and Hand-Held Breast Ultrasound in the Screening of Dense Breasts
    Philadelpho, Fernanda
    Gregorio Calas, Maria Julia
    Coutinho Carneiro, Gracy de Almeida
    Silveira, Isabela Cunha
    Ribeiro Vaz, Andreia Brandao
    Coelho Nogueira, Adriana Maria
    Bergmann, Anke
    Proenca Lobo Lopes, Flavia Paiva
    REVISTA BRASILEIRA DE GINECOLOGIA E OBSTETRICIA, 2021, 43 (03): : 190 - 199
  • [3] A Comparison of the Acceptance of Female Subjects Between Mammography, Automated Breast Ultrasound and Hand-Held Ultrasound
    Gao, Xican
    Liu, Liwen
    Yan, Jingru
    Yang, Shanling
    Shu, Rui
    Ju, Yan
    Zhang, Ge
    Xiao, Yao
    Song, Hongping
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2019, 9 (04) : 768 - 775
  • [4] Automated breast ultrasound compared to hand-held ultrasound in surveillance after breast-conserving surgery
    Depretto, Catherine
    Liguori, Alessandro
    Primolevo, Alessandra
    Di Cosimo, Serena
    Cartia, Francesco
    Ferranti, Claudio
    Scaperrotta, Gianfranco P.
    TUMORI JOURNAL, 2021, 107 (02): : 132 - 138
  • [5] Whole Breast Ultrasound: Comparison of the Visibility of Suspicious Lesions with Automated Breast Volumetric Scanning Versus Hand-Held Breast Ultrasound
    Kuzmiak, Cherie M.
    Ko, Eun Y.
    Tuttle, Laura A.
    Steed, Doreen
    Zeng, Donglin
    Yoon, Sora C.
    ACADEMIC RADIOLOGY, 2015, 22 (07) : 870 - 879
  • [6] Comparison of automated breast volume scanning to hand-held ultrasound and mammography
    Wang, Zhi Li
    Xw, Jian Hong
    Li, Jun Lai
    Huang, Yan
    Tang, Jie
    RADIOLOGIA MEDICA, 2012, 117 (08): : 1287 - 1293
  • [7] Diagnostic value of an automated breast volume scanner compared with a hand-held ultrasound: a meta-analysis
    Zhang, Xiaohui
    Chen, Juan
    Zhou, Yidong
    Mao, Feng
    Lin, Yan
    Shen, Songjie
    Sun, Qiang
    Ouyang, Zhaolian
    GLAND SURGERY, 2019, 8 (06) : 698 - +
  • [8] Is there an extraclinical value of automated breast volume scanner compared with hand-held ultrasound? A pilot study
    Zhan, Jia
    Diao, Xue-Hong
    Pang, Yun
    Wang, Yan
    Chen, Lin
    Chen, Yue
    MEDICINE, 2017, 96 (37)
  • [9] Evaluation of an automated breast volume scanner according to the fifth edition of BI-RADS for breast ultrasound compared with hand-held ultrasound
    Choi, Eun Jung
    Choi, Hyemi
    Park, Eun Hae
    Song, Ji Soo
    Youk, Ji Hyun
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 99 : 138 - 145
  • [10] Automated whole breast segmentation for hand-held ultrasound with position information: Application to breast density estimation
    Chang, Jie-Fan
    Huang, Chiun-Sheng
    Chang, Ruey-Feng
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 197