Changes in Peripheral Refraction, Higher-Order Aberrations, and Accommodative Lag With a Radial Refractive Gradient Contact Lens in Young Myopes

被引:33
|
作者
Paune, Jaume [1 ]
Thivent, Solene [2 ]
Armengol, Jesus [2 ]
Quevedo, Lluisa [2 ]
Faria-Ribeiro, Miguel [3 ]
Gonzalez-Meijome, Jose M. [3 ]
机构
[1] Ctr Med Teknon, Dept Optometry, Barcelona, Spain
[2] Univ Politecn Cataluna, Barcelona Tech, Dept Opt & Optometry, Barcelona, Spain
[3] Univ Minho, Dept & Ctr Phys, Clin & Expt Optometry Res Lab CEORLab, Braga, Portugal
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2016年 / 42卷 / 06期
关键词
Peripheral refraction; Aberrometry; Lag of accommodation; Radial refractive gradient contact lens; Myopia; OPTICAL TREATMENT STRATEGIES; PROGRESSIVE ADDITION LENSES; RANDOMIZED CLINICAL-TRIAL; AXIAL LENGTH ELONGATION; WAVE-FRONT ABERRATIONS; SINGLE-VISION; EYE GROWTH; HONG-KONG; OVERNIGHT ORTHOKERATOLOGY; INFANT MONKEYS;
D O I
10.1097/ICL.0000000000000222
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate changes in the peripheral refraction (PR), visual quality, and accommodative lag with a novel soft radial refractive gradient (SRRG) experimental contact lens that produces peripheral myopic defocus. Methods: 59 myopic right eyes were fitted with the lens. The PR was measured up to 30 degrees in the nasal and temporal horizontal visual fields and compared with values obtained without the lens. The accommodative lag was measured monocularly using the distance-induced condition method at 40 cm, and the higher-order aberrations (HOAs) of the entire eye were obtained for 3- and 5-mm pupils by aberrometry. Visual performance was assessed through contrast sensitivity function (CSF). Results: With the lens, the relative PR became significantly less hyperopic from 30 degrees to 15 degrees temporally and 30 degrees nasally in the M and J0 refractive components (P < 0.05). Cylinder foci showed significant myopization from 30 degrees to 15 degrees temporally and 30 degrees to 25 degrees nasally (P < 0.05). The HOAs increased significantly, the CSF decreased slightly but reached statistical significance for 6 and 12 cycles per degree (P < 0.05), and the accommodative lag decreased significantly with the SRRG lens (P = 0.0001). There was a moderate correlation between HOAs and CSF at medium and high spatial frequencies. Conclusion: The SRRG lens induced a significant change in PR, particularly in the temporal retina. Tangential and sagittal foci changed significantly in the peripheral nasal and temporal retina. The decreased accommodative lag and increased HOAs particularly in coma-like aberration may positively affect myopia control. A longitudinal study is needed to confirm this potential.
引用
收藏
页码:380 / 387
页数:8
相关论文
共 8 条
  • [1] Comparison of peripheral refraction and higher-order aberrations between orthokeratology and multifocal soft contact lens designed with highly addition
    Huang, Yingying
    Li, Xue
    Ding, Chenglu
    Chen, Yunyun
    Mao, Xinjie
    Chen, Hao
    Bao, Jinhua
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (05) : 1755 - 1762
  • [2] Changes in Higher Order Wavefront Aberrations After Contact Lens Corneal Refractive Therapy and LASIK Surgery
    Goldstone, Robert N.
    Yildiz, Elvin H.
    Fan, Vincent C.
    Asbell, Penny A.
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 348 - 355
  • [3] Two-Dimensional Peripheral Refraction and Higher-Order Wavefront Aberrations Induced by Orthokeratology Lenses Decentration
    Xue, Minsong
    Lin, Zhenghua
    Wu, Haoran
    Xu, Qinglin
    Wen, Longbo
    Luo, Zhiwei
    Hu, Ziqi
    Li, Xiaoning
    Yang, Zhikuan
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2023, 12 (10):
  • [4] On-Eye Evaluation of Peripheral Higher-Order Aberrations and Image Quality of Contact Lens Based on Wavefront Aberrometry
    Shen, J.
    Thibos, L. N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [5] Effect of LASIK and Contact Lens Corneal Refractive Therapy on Higher Order Aberrations and Contrast Sensitivity Function
    Anera, Rosario G.
    Villa, Cesar
    Jimenez, Jose R.
    Gutierrez, Ramon
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (03) : 277 - 284
  • [6] Relative peripheral refraction, higher-order aberrations, and visual quality with single-vision, progressive-multifocal, multifocal, and dual-focus soft contact lenses
    Yeh, Mike Chih-Wei
    Hsiao, John Ching-Jen
    Tsang, Dorcas
    Spors, Frank
    Cheng, Ching-Ying
    OPTIK, 2023, 273
  • [7] Long-term changes in classified higher-order aberrations after implanting an EVO intraocular collamer lens
    Chen, Xun
    Miao, Huamao
    Li, Boliang
    Cheng, Mingrui
    Lin, I-Chun
    Lei, Yadi
    Jiang, Yinjie
    Wang, Xiaoying
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [8] Comparing the Early Changes in Classified Higher-Order Aberrations Before and After Non-Toric and Toric Implantable Collamer Lens V4c Implantation
    Lin, I-Chun
    Chen, Xun
    Cheng, Mingrui
    Miao, Huamao
    Li, Boliang
    Jiang, Yinjie
    Lei, Yadi
    Xu, Yilin
    Wang, Xiaoying
    Zhou, Xingtao
    CURRENT EYE RESEARCH, 2024, 49 (11) : 1154 - 1160