The Impact of High-Flow Nasal Cannula Device, Nebulizer Type, an Placement on Trans-Nasal Aerosol Drug Delivery

被引:11
作者
Li, Jie [1 ]
Williams, Lucas [1 ]
Fink, James B. [1 ]
机构
[1] Rush Univ, Dept Cardiopulm Sci, Div Resp Care, 600 S Paulin St,Suite 765, Chicago, IL 60612 USA
关键词
high-flow nasal cannula; aerosol therapy; nebulizer; THERAPY;
D O I
10.4187/respcare.09133
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Aerosol delivery via high-flow nasal cannula (HFNC) has been increasingly used in recent years. However, the effects of different HFNC devices, nebulizer types, and placement on aerosol deposition remain largely unknown. METHODS: An adult manikin with anatomically correct upper airway was used with a collection tiller placed between the manikin's trachea and a breathing simulator, composed of a dual-chamber model lung driven by a critical care ventilator. Three HFNC device configurations were compared, with vi brating mesh nebulizer and small-volume nebulizer placed at the humidifier (inlet for Optiflow and outlet for Airvo 2) and proximal to the nasal cannula at gas flows of 10, 20, 40 and 60 L/min, in quiet and distressed breathing patterns. Albuterol (2.5 mg) was nebulized for each condition (no. = 3). The drug was eluted from the collection filter and assayed with ultraviolet spectrophotometry (276 nm). RESULTS: At all settings, except when a nebulizer was placed proximal to the nasal cannula with the Optiflow and when the HFNC flow was set at 60 L/min, the vibrating mesh nebulizer generated a higher inhaled dose than did the small-volume nebulizer (all P < .05). With the exception of distressed breathing at an HFNC flow of 10 L/min, the inhaled dose with the vibrating mesh nebulizer placed at the humidifier was greater than with the vibrating mesh nebulizer placed proximal to the nasal cannula (all P < .05), Optiflow provided a higher inhaled dose than did Airvo 2 with either AirSpiral or 9001/301 circuits with the vibrating mesh nebulizer placed at the humidifier (all P < .05). CONCLUSIONS: During transnasal aerosol delivery, the vibrating mesh nebulizer generated a higher inhaled dose than did the small-volume nebulizer when the nebulizer was placed at the humidifier. With the vibrating mesh nebulizer placed at the humidifier and an IIENC flow > 10 L/min, the inhaled dose was higher than with the vibrating mesh nebulizer placed proximal to the nasal cannula, and the inhaled dose was higher with Optiflow than with Airvo 2.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 15 条
  • [1] Oral Versus Nasal High-Flow Bronchodilator Inhalation in Chronic Obstructive Pulmonary Disease
    Braeunlich, Jens
    Wirtz, Hubert
    [J]. JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2018, 31 (04) : 248 - 254
  • [2] Aerosol Delivery with Two Nebulizers Through High-Flow Nasal Cannula: A Randomized Cross-Over Single-Photon Emission Computed Tomography-Computed Tomography Study
    Dugernier, Jonathan
    Hesse, Michel
    Jumetz, Thibaud
    Bialais, Emilie
    Roeseler, Jean
    Depoortere, Virginie
    Michotte, Jean-Bernard
    Wittebole, Xavier
    Ehrmann, Stephan
    Laterre, Pierre-Francois
    Jamar, Francois
    Reychler, Gregory
    [J]. JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (05) : 349 - 358
  • [3] Worldwide Clinical Practice of High-Flow Nasal Cannula and Concomitant Aerosol Therapy in the Adult ICU Setting
    Li, Jie
    Tu, Meilien
    Yang, Lei
    Jing, Guoqiang
    Fink, James B.
    Burtin, Chris
    de Andrade, Armele Dornelas
    Gong, Lingyue
    Xie, Lixin
    Ehrmann, Stephan
    [J]. RESPIRATORY CARE, 2021, 66 (09) : 1416 - 1424
  • [4] A narrative review on trans-nasal pulmonary aerosol delivery
    Li, Jie
    Fink, James B.
    MacLoughlin, Ronan
    Dhand, Rajiv
    [J]. CRITICAL CARE, 2020, 24 (01):
  • [5] Year in Review 2019: High-Flow Nasal Cannula Oxygen Therapy for Adult Subjects
    Li, Jie
    Jing, Guoqiang
    Scott, J. Brady
    [J]. RESPIRATORY CARE, 2020, 65 (04) : 545 - 557
  • [6] The Clinical Impact of Flow Titration on Epoprostenol Delivery via High Flow Nasal Cannula for ICU Patients with Pulmonary Hypertension or Right Ventricular Dysfunction: A Retrospective Cohort Comparison Study
    Li, Jie
    Gurnani, Payal K.
    Roberts, Keith M.
    Fink, James B.
    Vines, David
    [J]. JOURNAL OF CLINICAL MEDICINE, 2020, 9 (02)
  • [7] In vitro comparison between inspiration synchronized and continuous vibrating mesh nebulizer during trans-nasal aerosol delivery
    Li, Jie
    Wu, Wei
    Fink, James B.
    [J]. INTENSIVE CARE MEDICINE EXPERIMENTAL, 2020, 8 (01)
  • [8] Dose Response to Transnasal Pulmonary Administration of Bronchodilator Aerosols via Nasal High-Flow Therapy in Adults with Stable Chronic Obstructive Pulmonary Disease and Asthma
    Li, Jie
    Zhao, Minghua
    Hadeer, Maierbati
    Luo, Jian
    Fink, James B.
    [J]. RESPIRATION, 2019, 98 (05) : 401 - 409
  • [9] Epoprostenol Delivered via High Flow Nasal Cannula for ICU Subjects with Severe Hypoxemia Comorbid with Pulmonary Hypertension or Right Heart Dysfunction
    Li, Jie
    Harnois, Lauren J.
    Markos, Bethelhem
    Roberts, Keith M.
    Al Homoud, Salma
    Liu, Jing
    Mirza, Sara
    Vines, David
    [J]. PHARMACEUTICS, 2019, 11 (06)
  • [10] The Ratio of Nasal Cannula Gas Flow to Patient Inspiratory Flow on Trans-nasal Pulmonary Aerosol Delivery for Adults: An in Vitro Study
    Li, Jie
    Gong, Lingyue
    Fink, James B.
    [J]. PHARMACEUTICS, 2019, 11 (05)