Assessment of one-way shear design of RC elements subjected to axial tension

被引:6
作者
Deifalla, A. [1 ]
机构
[1] Future Univ Egypt FUE, Dept Struct Engn & Construct Management, New Cairo 11835, Egypt
关键词
One-way shear; Axial tension; Aggregate interlock; Size effect; CONCRETE SLABS; STRENGTH; BEAMS; REINFORCEMENT; TORSION; COMPRESSION; CRACKING;
D O I
10.1016/j.cscm.2021.e00620
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The Shear failure of reinforced concrete is brittle with no warning. In addition, tensile forces could widen the concrete cracking and cause premature failure. Thus, worsen the situation, which could have disastrous consequences in many cases as shown in Fig. 1a. There is a lack of agreement between various design code provisions for the case of one-way shear combined tensile forces. A total of 897 concrete elements tested under one-way shear was compiled, which contain 113 elements tested under one-way shear and tension. A review of recent findings and the provisions of current design codes for concrete subjected to one-way shear and tensile forces. In addition, a comparative study was conducted on the strength calculated using design codes. Moreover, the effect of various parameters including but not limited to the tensile axial force, the size, the flexure reinforcement ratio, the concrete strength, and the shear span to depth ratio on the design using selected design codes were examined. Last but not least, concluding remarks were outlined, which could help further the development of current design codes. In particular, design codes that are based on physically sound models were found to be more accurate for shear design with or without tension compared to other design codes. However, there is room for improvement in terms of consistency and accounting for various effective parameters.
引用
收藏
页数:20
相关论文
共 58 条
  • [1] Tests on Shear Behaviour with Concurrent Normal Tensile Action
    Adam, Viviane
    Classen, Martin
    Hegger, Josef
    [J]. BETON- UND STAHLBETONBAU, 2020, 115 (10) : 821 - 831
  • [2] Cheer strength of members without transverse reinforcement
    Adebar, P
    Collins, MP
    [J]. CANADIAN JOURNAL OF CIVIL ENGINEERING, 1996, 23 (01) : 30 - 41
  • [3] [Anonymous], 2014, STANDARD TEST METHOD
  • [4] [Anonymous], 2014, ACI 318 14
  • [5] [Anonymous], 1969, J STRUCT DIV, DOI 10.1061/JSDEAG.0002353
  • [6] ASCE-ACI Committee 445, 1999, 445 ASCEACI
  • [7] Bara H.C, 1971, INVESTIGATION EFFECT
  • [8] BHIDE SB, 1989, ACI STRUCT J, V86, P570
  • [9] Influence of uniaxial tension and compression on shear strength of concrete slabs without shear reinforcement under concentrated loads
    Bui, T. T.
    Nana, W. S. A.
    Abouri, S.
    Limam, A.
    Tedoldi, B.
    Roure, T.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2017, 146 : 86 - 101
  • [10] Collins M.P, 2001, MAPUN ENGLISH DICT