Sensitive detection of topiramate degradation products by high-performance liquid chromatography/electrospray ionization mass spectrometry using ion-pairing reagents and polarity switching

被引:6
作者
Pinto, Eduardo Costa [1 ,2 ]
Xu, Chengdong [2 ]
Cabral, Lucio Mendes [1 ]
Armstrong, Daniel W. [2 ]
de Sousa, Valeria Pereira [1 ]
机构
[1] Univ Fed Rio de Janeiro, Fac Pharm, Dept Pharmaceut, Av Carlos Chagas Filho 373,Sala 15, BR-21941902 Rio De Janeiro, RJ, Brazil
[2] Univ Texas Arlington, Dept Chem & Biochem, Arlington, TX 76019 USA
关键词
ELECTROSPRAY-IONIZATION; HUMAN PLASMA; LC-MS; QUANTIFICATION; IMPURITIES; EXTRACTION; SEPARATION; ANIONS; DRUGS;
D O I
10.1002/rcm.8321
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale The chromatographic analysis of topiramate and its degradation products is challenging due to the absence of chromophoric moieties in their structures, the wide polarity range of the compounds and their ionization differences. This work proposes two new mass spectrometry approaches for evaluating these analytes. Methods Based on the calculated experimental limit of detection (LOD), a highly sensitive high-performance liquid chromatography (HPLC) paired-ion electrospray ionization mass spectrometry (PIESI-MS) method was developed for the determination of topiramate inorganic degradation products. The influence of different solvent systems on the LODs for topiramate and its main degradation products was determined in both positive/negative ionization modes. In addition, a HPLC method to analyze both organic and inorganic degradation products was proposed by mass spectrometry with positive/negative ion switching electrospray ionization. Results A sensitive HPLC/PIESI-MS method was achieved for the efficient separation of topiramate inorganic degradation products. Both sulfate and sulfamate were detected in the positive selected ion monitoring (SIM) mode with an increased sensitivity compared with the negative SIM mode. The HPLC/ESI-MS analysis with positive/negative ion switching allowed the simultaneous separation and detection of the major degradation products of topiramate in a 10-min run using a single column and a single detector. Conclusions Two new alternative MS approaches for analyzing the main degradation products of topiramate were developed. The proposed methods are considered advantageous over the existing methods and can be applied to quality control studies of topiramate.
引用
收藏
页码:116 / 124
页数:9
相关论文
共 50 条
[1]   Mass Spectrometry, Review of the Basics: Ionization [J].
Awad, Hanan ;
Khamis, Mona M. ;
El-Aneed, Anas .
APPLIED SPECTROSCOPY REVIEWS, 2015, 50 (02) :158-175
[2]   High-performance liquid chromatographic study of topiramate and its impurities [J].
Biro, A. ;
Pergel, E. ;
Arvai, G. ;
Ilisz, I. ;
Szepesi, G. ;
Peter, A. ;
Lukacs, F. .
CHROMATOGRAPHIA, 2006, 63 (Suppl 13) :S137-S141
[3]   Medical treatment of obesity: The past, the present and the future [J].
Bray, George A. .
BEST PRACTICE & RESEARCH CLINICAL GASTROENTEROLOGY, 2014, 28 (04) :665-684
[4]   Evaluation of Flexible Linear Tricationic Salts as Gas-Phase Ion-Pairing Reagents for the Detection of Divalent Anions in Positive Mode ESI-MS [J].
Breitbach, Zachary S. ;
Warnke, Molly M. ;
Wanigasekara, Eranda ;
Zhang, Xiaotong ;
Armstrong, Daniel W. .
ANALYTICAL CHEMISTRY, 2008, 80 (22) :8828-8834
[5]   Mass spectrometric detection of trace anions: The evolution of paired-ion electrospray ionization (PIESI) [J].
Breitbach, Zachary S. ;
Berthod, Alain ;
Huang, Ke ;
Armstrong, Daniel W. .
MASS SPECTROMETRY REVIEWS, 2016, 35 (02) :201-218
[6]   Practical implications of some recent studies in electrospray ionization fundamentals [J].
Cech, NB ;
Enke, CG .
MASS SPECTROMETRY REVIEWS, 2001, 20 (06) :362-387
[7]  
Chen S, 1999, RAPID COMMUN MASS SP, V13, P1980, DOI 10.1002/(SICI)1097-0231(19991030)13:20<1980::AID-RCM741>3.0.CO
[8]  
2-C
[9]   Sensitive analysis of metal cations in positive ion mode electrospray ionization mass spectrometry using commercial chelating agents and cationic ion-pairing reagents [J].
Dodbiba, Edra ;
Xu, Chengdong ;
Wanigasekara, Eranda ;
Armstrong, Daniel W. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (09) :1005-1013
[10]   Use of ion pairing reagents for sensitive detection and separation of phospholipids in the positive ion mode LC-ESI-MS [J].
Dodbiba, Edra ;
Xu, Chengdong ;
Payagala, Tharanga ;
Wanigasekara, Eranda ;
Moon, Myeong Hee ;
Armstrong, Daniel W. .
ANALYST, 2011, 136 (08) :1586-1593