Repeatability of central corneal thickness measurements of donor corneas in preservation chamber using Fourier-domain anterior segment optical coherence tomography

被引:5
|
作者
Golla, Abhinav [1 ]
Wang, Li [1 ]
Morris, Caleb [1 ]
Weikert, Mitchell P. [1 ,2 ]
Khandelwal, Sumitra S. [1 ,2 ]
机构
[1] Baylor Coll Med, Cullen Eye Inst, 6565 Fannin St NC505B, Houston, TX 77030 USA
[2] Lions Eye Bank Texas, 1977 Butler Blvd, Houston, TX 77030 USA
关键词
Central corneal thickness; Optical coherence tomography; Repeatability; Donor cornea; Preservation;
D O I
10.1007/s10561-018-9724-z
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
To evaluate the repeatability of central corneal thickness (CCT) measurements in donor corneas using optical coherence tomography (OCT, RTVueOptovue, Inc., Fremont, CA). Consecutive corneas were measured by a single observer using the RTVue. All corneas were preserved in the Transend chamber and Life4 degrees C media (Numedis, Inc., Isanti, MN/USA) and stored at 4 degrees C. The repeatability was evaluated using a pooled within-subject standard deviation (SD), coefficient of variation (CoV), and intraclass correlation coefficient (ICC). To investigate inter-observer repeatability, a second observer independently measured the CCT for each image scan. CCT was measured in 32 eyes from 18 donors. Measurements were independently repeated by a second observer. The corneas had a mean CCT of 490.99m +/- 65.95 (381-642) as measured by Observer 1. For observer 1, the SD value for the CCT was 2.94m, the CoV value was 0.597%, and the ICC value was 0.998 (95% CI 0.996, 0.999). For observer 2, the SD value was 5.91m, the CoV value was 1.21%, and the ICC value was 0.992 (95% CI 0.985, 0.996). The Kappa statistic 21.88% with a p value<0.001. The Bland-Altman plot shows that the average CCT measurements between the two observers were within 20m of each other. The CCT measurements of donor corneas in the preservation chamber using Fourier domain OCT is highly repeatable.
引用
收藏
页码:717 / 720
页数:4
相关论文
共 50 条
  • [1] Repeatability of central corneal thickness measurements of donor corneas in preservation chamber using Fourier-domain anterior segment optical coherence tomography
    Abhinav Golla
    Li Wang
    Caleb Morris
    Mitchell P. Weikert
    Sumitra S. Khandelwal
    Cell and Tissue Banking, 2018, 19 : 717 - 720
  • [2] Use of Fourier-Domain Optical Coherence Tomography to Evaluate Anterior Stromal Opacities in Donor Corneas
    Bald, Matthew R.
    Stoeger, Christopher
    Galloway, Joshua
    Tang, Maolong
    Holiman, Jeffrey
    Huang, David
    JOURNAL OF OPHTHALMOLOGY, 2013, 2013
  • [3] Repeatability of Corneal Epithelial Thickness Measurements Using Fourier-Domain Optical Coherence Tomography in Normal and Post-LASIK Eyes
    Ma, Xingxuan Jack
    Wang, Li
    Koch, Douglas D.
    CORNEA, 2013, 32 (12) : 1544 - 1548
  • [4] Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mohammed
    PLOS ONE, 2021, 16 (06):
  • [5] Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mo
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 884 - 885
  • [6] Pachymetric Mapping Repeatability Using Fourier-Domain Optical Coherence Tomography in Corneal Opacities
    El Gendy, N. M. Samy
    Li, Y.
    Huang, D.
    Zhang, X.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [7] Detailed visualization of the anterior segment using Fourier-domain optical coherence tomography
    Asrani, Sanjay
    Sarunic, Marinko
    Santiago, Cecilia
    Izatt, Joseph
    ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (06) : 765 - 771
  • [8] Comparison of Fourier-Domain and Time-Domain Optical Coherence Tomography for Assessment of Corneal Thickness and Intersession Repeatability
    Prakash, Gaurav
    Agarwal, Amar
    Jacob, Soosan
    Kumar, Dhivya Ashok
    Agarwal, Athiya
    Banerjee, Rumki
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (02) : 282 - 290
  • [9] Consistency of corneal sublayer thickness measurements using Fourier-domain optical coherence tomography after phacoemulsification
    Lopez-Miguel, Alberto
    Calabuig-Goena, Maria
    Marques-Fernandez, Victoria
    Fernandez, Itziar
    Alio, Jorge L.
    Maldonado, Miguel J.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (06) : 540 - 545
  • [10] Corneal epithelial thickness measured by Fourier-domain optical coherence tomography
    Wang, Ting
    Li, Fengjie
    Wang, Shuting
    Shi, Weiyun
    SPEKTRUM DER AUGENHEILKUNDE, 2016, 30 (01) : 3 - 9