Development and validation of an assay for the measurement of gentamicin concentrations in dried blood spots using UHPLC-MS/MS

被引:6
|
作者
Anibaletto dos Santos, Ana Laura [1 ,2 ]
Cezimbra da Silva, Anne Caroline [1 ,2 ]
Feltraco Lizot, Lilian de Lima [1 ,2 ]
Schneider, Anelise [2 ]
Meireles, Yasmin Fazenda [2 ]
Hahn, Roberta Zilles [1 ]
Pagnussat, Lidiane Riva [4 ]
Nonnenmacher, Julia Livia [5 ]
Hahn, Siomara Regina [3 ]
Linden, Rafael [1 ,2 ]
机构
[1] Univ Feevale, Analyt Toxicol Lab, Novo Hamburgo, RS, Brazil
[2] Univ Feevale, Grad Program Toxicol & Analyt Toxicol, Novo Hamburgo, Brazil
[3] Univ Passo Fundo, Coll Pharm, Passo Fundo, RS, Brazil
[4] Hosp Sao Vicente Paulo, Passo Fundo, RS, Brazil
[5] Univ Passo Fundo, Multidisciplinary Residency Program, Passo Fundo, RS, Brazil
关键词
Gentamicin; UHPLC-MS/MS; Dried blood spots; Therapeutic drug monitoring; Neonates; MASS-SPECTROMETRY; LC-MS/MS; HEMATOCRIT; TIME;
D O I
10.1016/j.jpba.2021.114448
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gentamicin sulfate (GEN) is an aminoglycoside antibiotic with a narrow therapeutic range of plasma concentrations. The collection of venous blood represents a significant burden for patients, especially in neonatology. Dried blood spots (DBS) obtained from capillary blood can be an alternative for drug measurements in this particular population. This study aimed to develop and validate an assay for the quantification of GEN in DBS using UHPLC-MS/MS. Total GEN concentrations were obtained by adding the individual concentrations of the GEN forms C1, C1a, and C2. The assay used a DBS disk containing approximately 17 mu L of blood for GEN quantitation in the range of 0.1-40 mg L-1. Measurement accuracy for total GEN was in the range of 102.6-108.6%, inter-assay precision was 11.3-13.1% and intra-assay precision was 9.1-12.8.% GEN was stable for 21 days at - 20 and 8 degrees C, but only for 24 h at room temperature. Blood Hct affected the accuracy within acceptable limits (93.8-95% at Hct% of 30, 104.3-113% at Hct% of 50). Blood spotted volume did not affect GEN measurement accuracy. Concentrations of GEN in DBS obtained after heel pricks were correlated to plasma levels in a small cohort of neonatal patients. However, percentual differences between estimated plasma concentrations and actual plasma levels presented values between - 64-35.3% (average difference of - 1.9%). The use of DBS for the measurement of GEN concentrations can increase access to TDM of this antibiotic due to the ease of sample collection and the facilitated specimen transportation logistics when testing is not available onsite. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Development and Validation of a UHPLC-MS/MS Method for the Analysis of Fusarium Mycotoxins in Onion
    Sari Rämö
    Minna Haapalainen
    Satu Latvala
    Food Analytical Methods, 2021, 14 : 1524 - 1536
  • [22] Thalidomide measurement in plasma and dried plasma spot by SPE combined with UHPLC-MS/MS for therapeutic drug monitoring
    Novellino, Renata Soares
    Chalom, Marc Yves
    Romano, Paschoalina
    Rezende Ebner, Persio de Almeida
    Seraphim, Julia Celestino
    Silva do Amaral, Ana Carolina
    Coelho Duarte, Nilo Jose
    Pedrosa, Tatiana Do Nascimento
    Neves Yuki, Emily Figueiredo
    Aikawa, Nadia Emi
    Pasoto, Sandra Gofinet
    Almeida da Silva, Clovis Artur
    Carvalho, Valdemir Melechco
    Bonfa, Eloisa
    Kanda Kupa, Leonard de Vinci
    BIOANALYSIS, 2022, 14 (15) : 1039 - 1050
  • [23] Measurement of total and unbound bictegravir concentrations in plasma and cerebrospinal fluid by UHPLC-MS/MS
    Rigo-Bonnin, Raul
    Manuel Tiraboschi, Juan
    Alvarez-Alvarez, Marta
    Ainara Perez-Fernandez, Gloria
    Sanjuas-Iglesias, Mercedes
    Scevola, Sofia
    Niubo, Jordi
    Videla, Sebastian
    Podzamczer, Daniel
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 185
  • [24] Determination of lesinurad in rat plasma by a UHPLC-MS/MS assay
    Zhou, Xiao-Yang
    Yuan, Ling-Jing
    Chen, Zhe
    Tang, Peng-Fei
    Li, Xiang-Yu
    Hu, Guo-Xin
    Cai, Jian-Ping
    CHEMISTRY CENTRAL JOURNAL, 2017, 11 : 1 - 7
  • [25] Determination of polymyxin B in dried blood spots using LC-MS/MS for therapeutic drug monitoring
    Huang, Xiaolan
    Liu, Xiaofen
    Wang, Yu
    Zhang, Jing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1192
  • [26] Development and Validation of UHPLC-MS/MS Assay for Therapeutic Drug Monitoring of High-dose Methotrexate in Children with Acute Lymphoblastic Leukemia
    Lian, Le-jing
    Lin, Bin
    Cui, Xiao
    He, Jie
    Wang, Zhe
    Lin, Xiao-dong
    Ye, Wei-jian
    Chen, Rui-jie
    Sun, Wei
    DRUG DESIGN DEVELOPMENT AND THERAPY, 2020, 14 : 4835 - 4843
  • [27] Quantification of ribociclib in dried blood spots by LC-MS/MS : Method development and clinical validation
    Braal, C. Louwrens
    Lam, Mei H.
    Rienks, Tineke
    van Tilborg, Claudia J.
    Heuts, Wendy
    Heijns, Joan B.
    Bos, Monique E. M. M.
    Mathijssen, Ron H. J.
    de Bruijn, Peter
    Koolen, Stijn L. W.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 201
  • [28] Development and method validation for determination of 128 pesticides in bananas by modified QuEChERS and UHPLC-MS/MS analysis
    Carneiro, Raphaella P.
    Oliveira, Fabiano A. S.
    Madureira, Fernando D.
    Silva, Gilsara
    de Souza, Wesley R.
    Lopes, Renata Pereira
    FOOD CONTROL, 2013, 33 (02) : 413 - 423
  • [29] Development and Validation of a UHPLC-MS/MS-Based Method to Quantify Cenobamate in Human Plasma Samples
    Charlier, Bruno
    Coglianese, Albino
    Operto, Francesca Felicia
    Coppola, Giangennaro
    de Grazia, Ugo
    Menna, Pierantonio
    Filippelli, Amelia
    Dal Piaz, Fabrizio
    Izzo, Viviana
    MOLECULES, 2022, 27 (21):
  • [30] UHPLC-MS/MS method for simultaneous determination of tacrolimus, Cyclosporine A, sirolimus and Everolimus in human blood and clinical application
    Wang, Jiaqing
    Liu, Tongtong
    Zhang, Dongjie
    Li, Jian
    Ning, Xiao
    Zhao, Zhigang
    Mei, Shenghui
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2025, 53 (01)