Development and validation of an assay for the measurement of gentamicin concentrations in dried blood spots using UHPLC-MS/MS

被引:6
|
作者
Anibaletto dos Santos, Ana Laura [1 ,2 ]
Cezimbra da Silva, Anne Caroline [1 ,2 ]
Feltraco Lizot, Lilian de Lima [1 ,2 ]
Schneider, Anelise [2 ]
Meireles, Yasmin Fazenda [2 ]
Hahn, Roberta Zilles [1 ]
Pagnussat, Lidiane Riva [4 ]
Nonnenmacher, Julia Livia [5 ]
Hahn, Siomara Regina [3 ]
Linden, Rafael [1 ,2 ]
机构
[1] Univ Feevale, Analyt Toxicol Lab, Novo Hamburgo, RS, Brazil
[2] Univ Feevale, Grad Program Toxicol & Analyt Toxicol, Novo Hamburgo, Brazil
[3] Univ Passo Fundo, Coll Pharm, Passo Fundo, RS, Brazil
[4] Hosp Sao Vicente Paulo, Passo Fundo, RS, Brazil
[5] Univ Passo Fundo, Multidisciplinary Residency Program, Passo Fundo, RS, Brazil
关键词
Gentamicin; UHPLC-MS/MS; Dried blood spots; Therapeutic drug monitoring; Neonates; MASS-SPECTROMETRY; LC-MS/MS; HEMATOCRIT; TIME;
D O I
10.1016/j.jpba.2021.114448
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gentamicin sulfate (GEN) is an aminoglycoside antibiotic with a narrow therapeutic range of plasma concentrations. The collection of venous blood represents a significant burden for patients, especially in neonatology. Dried blood spots (DBS) obtained from capillary blood can be an alternative for drug measurements in this particular population. This study aimed to develop and validate an assay for the quantification of GEN in DBS using UHPLC-MS/MS. Total GEN concentrations were obtained by adding the individual concentrations of the GEN forms C1, C1a, and C2. The assay used a DBS disk containing approximately 17 mu L of blood for GEN quantitation in the range of 0.1-40 mg L-1. Measurement accuracy for total GEN was in the range of 102.6-108.6%, inter-assay precision was 11.3-13.1% and intra-assay precision was 9.1-12.8.% GEN was stable for 21 days at - 20 and 8 degrees C, but only for 24 h at room temperature. Blood Hct affected the accuracy within acceptable limits (93.8-95% at Hct% of 30, 104.3-113% at Hct% of 50). Blood spotted volume did not affect GEN measurement accuracy. Concentrations of GEN in DBS obtained after heel pricks were correlated to plasma levels in a small cohort of neonatal patients. However, percentual differences between estimated plasma concentrations and actual plasma levels presented values between - 64-35.3% (average difference of - 1.9%). The use of DBS for the measurement of GEN concentrations can increase access to TDM of this antibiotic due to the ease of sample collection and the facilitated specimen transportation logistics when testing is not available onsite. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] A simple and sensitive HILIC-based UHPLC-MS/MS method for quantifying of rivaroxaban in dried blood spots: Application in comparison with the plasma sample method
    Iqbal, Muzaffar
    Ullah, Zabih
    Ezzeldin, Essam
    Khalil, Nasr Y.
    Al-Shakliah, Nasser S.
    Alrasheed, Abdulrahman
    Ahmad, Ishtiaque
    Albehlal, Luluh
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 198
  • [12] Determination of docetaxel in dried blood spots by LC-MS/MS: Method development, validation and clinical application
    Raymundo, S.
    Muller, V. V.
    Andriguetti, N. B.
    Tegner, M.
    Artmann, A. C.
    Kluck, H. M.
    Franzoi, M. A.
    Vilela, R. M. M.
    Schwartsmann, G.
    Linden, R.
    Antunes, M. V.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 157 : 84 - 91
  • [13] Validation of a high-sensitivity assay for zatebradine in dried blood spots of human blood at pg/ml concentrations using HILIC-MS/MS
    Michi, Marco
    Ferrari, Luca
    BIOANALYSIS, 2010, 2 (11) : 1863 - 1871
  • [14] Method development and validation for acrylamide in potato cutlet by UHPLC-MS/MS
    Kumari, Alka
    Bhattacharya, Bhaswati
    Agarwal, Tripti
    Paul, Vijay
    Maurya, Vaibhav Kumar
    Chakkaravarthi, S.
    Simal-Gandara, J.
    FOOD CONTROL, 2023, 151
  • [15] Steroid profiling by UHPLC-MS/MS in dried blood spots collected from healthy women with and without testosterone gel administration
    Salamin, Olivier
    Nicoli, Raul
    Xu, Cheng
    Boccard, Julien
    Rudaz, Serge
    Pitteloud, Nelly
    Saugy, Martial
    Kuuranne, Tiia
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 204
  • [16] Sensitive determination of gentamicin in plasma using ion-exchange solid-phase extraction followed by UHPLC-MS/MS analysis
    dos Santos, Ana Laura Anibaletto
    da Silva, Anne Caroline Cezimbra
    Lizot, Lilian de Lima Feltraco
    Schneider, Anelise
    Hahn, Roberta Zilles
    Meireles, Yasmin Fazenda
    Pagnussat, Lidiane Riva
    Nonnenmacher, Julia Livia
    Hahn, Siomara Regina
    Linden, Rafael
    PRACTICAL LABORATORY MEDICINE, 2021, 26
  • [17] Investigation of the 12-Month Stability of Dried Blood and Urine Spots Applying Untargeted UHPLC-MS Metabolomic Assays
    Palmer, Elliott A.
    Cooper, Helen J.
    Dunn, Warwick B.
    ANALYTICAL CHEMISTRY, 2019, 91 (22) : 14306 - 14313
  • [18] Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
    Shokati, Touraj
    Bodenberger, Nicholas
    Gadpaille, Holly
    Schniedewind, Bjoern
    Vinks, Alexander A.
    Jiang, Wenlei
    Alloway, Rita R.
    Christians, Uwe
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2015, (105):
  • [19] Clinical validation and implementation of a multiplexed immunosuppressant assay in dried blood spots by LC-MS/MS
    Sadilkova, Katerina
    Busby, Barbara
    Dickerson, Jane A.
    Rutledge, Joe C.
    Jack, Rhona M.
    CLINICA CHIMICA ACTA, 2013, 421 : 152 - 156
  • [20] Development and validation of an assay to measure cannabidiol and Δ9-tetrahydrocannabinol in human EDTA plasma by UHPLC-MS/MS
    Ocque, Andrew J.
    Hagler, Colleen E.
    DiFrancesco, Robin
    Lombardo, Jeffrey
    Morse, Gene D.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1112 : 56 - 60