Chemical sensors based on piezoresistive cantilever array

被引:6
|
作者
Yu, XM [1 ]
Zhang, DC [1 ]
Wang, CS [1 ]
Du, XF [1 ]
Wang, XB [1 ]
Ruan, Y [1 ]
机构
[1] Peking Univ, Inst Microelect, Beijing 100871, Peoples R China
关键词
D O I
10.1088/0256-307X/20/9/366
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
U-shaped and rectangle piezoresistive cantilever arrays have been designed with the analysing results of stress, noise and sensitivity of the cantilevers. Based on silicon micromachining technology, the piezoresistive cantilevers were fabricated by using polysilicon as the piezoresistive materials. With the measurement results of noise and sensitivity, the Hooge factor is calculated to be 3 x 10(-3), the gauge factor is 27, and the minimum detectable deflection of piezoresistive cantilevers are calculated to be 1.0 nm for rectangle cantilever and 0.5 nm for the U-shaped cantilever at a 6 V bias voltage and a 1000 Hz measurement bandwidth. Using polymer-coated cantilevers as individual sensors, their responses to water vapour and ammonia were tested by measuring their output voltage signals. The measured results show that the sensor sensitivity to ammonia can reach a few ppm and the sensor responses are quick.
引用
收藏
页码:1637 / 1640
页数:4
相关论文
共 50 条
  • [31] Piezoresistive cantilever based nanoflow and viscosity sensor for microchannels
    Quist, Arjan
    Chand, Ami
    Ramachandran, Srinivasan
    Cohen, Dan
    Lal, Ratnesh
    LAB ON A CHIP, 2006, 6 (11) : 1450 - 1454
  • [32] Micromachined Piezoresistive Accelerometers Based on an Asymmetrically Gapped Cantilever
    Li, Yuefa
    Zheng, Qinglong
    Hu, Yating
    Xu, Yong
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2011, 20 (01) : 83 - 94
  • [33] The spring constant calibration of the piezoresistive cantilever based biosensor
    Jozwiak, G.
    Kopiec, D.
    Zawierucha, P.
    Gotszalk, T.
    Janus, P.
    Grabiec, P.
    Rangelow, I. W.
    EUROSENSORS XXIV CONFERENCE, 2010, 5 : 838 - 841
  • [34] The spring constant calibration of the piezoresistive cantilever based biosensor
    Jozwiak, G.
    Kopiec, D.
    Zawierucha, P.
    Gotszalk, T.
    Janus, P.
    Grabiec, P.
    Rangelow, I. W.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 170 : 201 - 206
  • [35] Cantilever transducers as a platform for chemical and biological sensors
    Lavrik, NV
    Sepaniak, MJ
    Datskos, PG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (07): : 2229 - 2253
  • [36] Review on diamond based piezoresistive sensors
    Werner, M
    Adamschik, M
    Gluche, P
    Kohn, E
    Fecht, HJ
    IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE 98) - PROCEEDINGS, VOLS 1 AND 2, 1998, : 147 - 152
  • [37] Piezoresistive biochemical sensors based on hydrogels
    Margarita Guenther
    Gerald Gerlach
    Thomas Wallmersperger
    Microsystem Technologies, 2010, 16 : 703 - 715
  • [38] Enhancement of Frequency Stability Using Synchronization of a Cantilever Array for MEMS-Based Sensors
    Torres, Francesc
    Uranga, Arantxa
    Riverola, Marti
    Sobreviela, Guillermo
    Barniol, Nuria
    SENSORS, 2016, 16 (10)
  • [39] Piezoresistive biochemical sensors based on hydrogels
    Guenther, Margarita
    Gerlach, Gerald
    Wallmersperger, Thomas
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2010, 16 (05): : 703 - 715
  • [40] Optical fiber array based simultaneous parallel monitoring of resonant cantilever sensors in liquid
    Mostafazadeh, Aref
    Yaralioglu, Goksen G.
    Urey, Hakan
    SENSORS AND ACTUATORS A-PHYSICAL, 2016, 242 : 132 - 139