Observational study of perioperative PtcCO2 and SPO2 in non-ventilated patients receiving epidural infusion or patient-controlled analgesia using a single earlobe monitor (TOSCA)

被引:35
作者
Kopka, A.
Wallace, E.
Reilly, G.
Binning, A.
机构
[1] Greater Glasgow Univ Hosp, So Gen Hosp, Dept Anaesthesia, Glasgow G514TF, Lanark, Scotland
[2] Greater Glasgow Univ Hosp, Gartnavel Gen Hosp, Dept Anaesthesia, Glasgow, Lanark, Scotland
关键词
capnometry; carbon dioxide; hypercapnia; hypercarbia; oxygenation; tissue; cutaneous; subcutaneous;
D O I
10.1093/bja/aem206
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. TOSCA, a non-invasive monitor with a single earlobe probe incorporating a Stow-Severinghaus electrode and optical sensor (Linde Medical Sensors AG, Basel, Switzerland), has previously been used with ventilated patients and in sleep laboratories. We recorded transcutaneous carbon dioxide pressures (Ptc(CO2)) and oxygen saturations (Sp(O2)) in non-ventilated patients to investigate opioid-induced respiratory depression. Methods. This observational cohort study included 28 ASA I and II patients, monitored between 10 p.m. and 6 a.m., before and after elective major laparotomy. After operation, patients I were kept on oxygen, 4 litre min(-1) and received either bupivacaine (0.1%) containing fentanyl (2 mu g ml(-1)) via epidural catheter (epidural analgesia group, EPI; n = 14) or morphine via patient-controlled analgesia infusion pump (PCA-morphine group, PCA; n= 14). Results. The preoperative median (lower/upper quartile) Ptc(CO2) was similar in both groups at around 5.5 kPa, but significantly higher after operation in PCA with 6.9 kPa (5.6/7.3) (P=0.02), accompanied by a longer hypercarbia time > 6 kPa of 6.6 h (0.1/8.0) (P=0.04), and lower respiratory rates of 13.9 breaths min(-1) (13.3/15.4) (P=0.04). In EPI, the corresponding results were 5.8 kPa (5.5/6.0), 1.2 h (0.1/4.3), and 16.2 breaths min(-1) (14.8/16.7). The perioperative median Sp(O2) in both groups was comparable within the normal range, although generally higher when on supplemental oxygen (P=0.26). The SpO(2) time < 94% was similar in both groups (P=0.33) as were pain scores (P=0.25). Conclusions. Ptc(CO2) recording in patients on PCA-morphine and supplemental oxygen revealed hypercapnia in the presence of normal respiratory rates and Sp(O2),,, values. This is recommended as an easy and sensitive monitor of respiratory depression and may have a role in the safe administration of opioid-analgesia.
引用
收藏
页码:567 / 571
页数:5
相关论文
共 16 条
  • [1] Respiratory and haemodynamic effects of acute postoperative pain management: evidence from published data
    Cashman, JN
    Dolin, SJ
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2004, 93 (02) : 212 - 223
  • [2] Limitations of transcutaneous carbon dioxide measurements for assessing long-term mechanical ventilation
    Cuvelier, A
    Grigoriu, B
    Molano, LC
    Muir, JF
    [J]. CHEST, 2005, 127 (05) : 1744 - 1748
  • [3] Downs John B, 2003, Respir Care, V48, P611
  • [4] Pain relief and safety after major surgery -: A prospective study of epidural and intravenous analgesia in 2696 patients
    Flisberg, P
    Rudin, Å
    Linnér, R
    Lundberg, CJF
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2003, 47 (04) : 457 - 465
  • [5] Supplemental oxygen impairs detection of hypoventilation by pulse oximetry
    Fu, ES
    Downs, JB
    Schweiger, JW
    Miguel, RV
    Smith, RA
    [J]. CHEST, 2004, 126 (05) : 1552 - 1558
  • [6] Respiratory rate and body mass in the first three years of life
    Gagliardi, L
    Rusconi, F
    Castagneto, M
    Porta, GLN
    Razon, S
    Pellegatta, A
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1997, 76 (02) : 151 - 154
  • [7] OxiCarbo®, a single sensor for the non-invasive measurement of arterial oxygen saturation and CO2 partial pressure at the ear lobe
    Gisiger, PA
    Palma, JP
    Eberhard, P
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) : 527 - 530
  • [8] HOOKER E A, 1989, Journal of Emergency Medicine, V7, P129, DOI 10.1016/0736-4679(89)90257-6
  • [9] Ko S, 2003, CAN J ANAESTH, V50, P679, DOI 10.1007/BF03018710
  • [10] *LIND MED SENS AG, TOSCA OP MAN