Complications and range of motion following plate fixation of metacarpal and phalangeal fractures

被引:238
|
作者
Page, SM [1 ]
Stern, PJ [1 ]
机构
[1] Univ Cincinnati, Coll Med, Dept Orthopaed Surg, Cincinnati, OH USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 1998年 / 23A卷 / 05期
关键词
D O I
10.1016/S0363-5023(98)80157-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Eighty-two patients with 105 metacarpal and/or phalangeal fractures stabilized with plates were retrospectively reviewed to assess complications and outcomes. Despite stable fixation and early mobilization, major complications were encounterec in 36% of fractures, especially with phalangeal and open fractures. Complications included stiffness, nonunion, plate prominence, infection, and tendon rupture. Forty-eight of 63 (76%) metacarpal fractures and 44 of 66 (67%) closed fractures had a final range of motion greater than 220 degrees; however, only 4 of 37 (11%) phalangeal fractues and 8 of 34 (24%) open fractures achieved this outcome. Despite technical advances in plate design and instrumentation, including lower-profile titanium plates, complications occur commonly with metacarpal and phalangeal fractures, leading to a high incidence of unsatisfactory results. We do not condemn plate fixation, and attribute many of our unsatisfactory results to the frequent use of plates in open and phalangeal fractures. Copyright (C) 1998 by the American Society for Surgery of the Hand.
引用
收藏
页码:827 / 832
页数:6
相关论文
共 50 条
  • [21] Complications Following Intramedullary Screw Fixation for Metacarpal Fractures: A Systematic Review
    Anene, Chibuzo C.
    Thomas, Terence L.
    Matzon, Jonas L.
    Jones, Christopher M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2024, 49 (10):
  • [22] Comparison of AO Titanium Locking Plate and Screw Fixation versus Anterograde Intramedullary Fixation for Isolated Unstable Metacarpal and Phalangeal Fractures
    Zhang, Bing
    Hu, Pan
    Yu, Kun-lun
    Bai, Jiang-bo
    Tian, De-hu
    Zhang, Gui-sheng
    Shao, Xin-zhong
    Zhang, Ying-ze
    ORTHOPAEDIC SURGERY, 2016, 8 (03) : 316 - 322
  • [23] Fixation choices for closed simple unstable oblique phalangeal and metacarpal fractures
    Kawamura, Kenji
    Chung, Kevin C.
    HAND CLINICS, 2006, 22 (03) : 287 - +
  • [24] FUNCTIONAL OUTCOME OF OPEN PHALANGEAL AND METACARPAL FRACTURES TREATED WITH EXTERNAL FIXATION
    Kannan, Kishore
    Palaniappan, Mathivanan
    Anbu, Srinivasan
    Kolundan, Kalyanasundaram
    Ganesan, Ramesh Prabu
    Karunanithi, Subramanian
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (77): : 5716 - 5720
  • [25] MANAGEMENT OF PHALANGEAL AND METACARPAL FRACTURES
    BROWN, PW
    SURGICAL CLINICS OF NORTH AMERICA, 1973, 53 (06) : 1393 - 1437
  • [26] Phalangeal and metacarpal fractures of the hand
    Lee, SG
    Jupiter, JB
    HAND CLINICS, 2000, 16 (03) : 323 - +
  • [27] INTERNAL FIXATION WITH THE LOW PROFILE PLATE SYSTEM COMPARED WITH KIRSCHNER WIRE FIXATION: CLINICAL RESULTS OF TREATMENT FOR METACARPAL AND PHALANGEAL FRACTURES
    Takigami, Hidetake
    Sakano, Hiroaki
    Saito, Tomoyuki
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2010, 15 (01): : 1 - 6
  • [28] Metacarpal and phalangeal fractures in athletes
    Capo, JT
    Hastings, H
    CLINICS IN SPORTS MEDICINE, 1998, 17 (03) : 491 - +
  • [29] Metacarpal and Phalangeal Fractures in Athletes
    Cotterell, Ilvy H.
    Richard, Marc J.
    CLINICS IN SPORTS MEDICINE, 2015, 34 (01) : 69 - +
  • [30] Treatment of Metacarpal and Phalangeal Fractures
    Terzis, Athanasios
    Neubrech, Florian
    Sauerbier, Michael
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2020, 158 (01): : 111 - 131