A comparison of inverse optimization algorithms for HDR/PDR prostate brachytherapy treatment planning

被引:33
作者
Dinkla, Anna M. [1 ]
van der Laarse, Rob [1 ]
Kaljouw, Emmie [1 ]
Pieters, Bradley R. [1 ]
Koedooder, Kees [1 ]
van Wieringen, Niek [1 ]
Bel, Arjan [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Radiat Oncol, NL-1105 AZ Amsterdam, Netherlands
关键词
Prostate neoplasms; Brachytherapy; Inverse planning; IPSA; HIPO; EGO-IIP; DOSE-RATE BRACHYTHERAPY; HDR-BRACHYTHERAPY; ANATOMY; CANCER; BOOST; RECOMMENDATIONS; ESCALATION; CATHETERS; IMPLANT; NUMBER;
D O I
10.1016/j.brachy.2014.09.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: Graphical optimization (GrO) is a common method for high-dose-rate/pulsed-dose-rate (PDR) prostate brachytherapy treatment planning. New methods performing inverse optimization of the dose distribution have been developed over the past years. The purpose is to compare GrO and two established inverse methods, inverse planning simulated annealing (IPSA) and hybrid inverse treatment planning and optimization (HIPO), and one new method, enhanced geometric optimization-interactive inverse planning (EGO-IIP), in terms of speed and dose volume histogram (DVH) parameters. METHODS AND MATERIALS: For 26 prostate cancer patients treated with a PDR brachytherapy boost, an experienced treatment planner optimized the dose distributions using four different methods: GrO, IPSA, HIPO, and EGO-IIP. Relevant DVH parameters (prostate-V-100%, D-90%, V-150%; urethra-D-0.1cm3 and D-1.0cm3; rectum-D-0.1cm3 and D-2.0cm3; bladder-D-2.0cm3) were evaluated and their compliance to the constraints. Treatment planning time was also recorded. RESULTS: All inverse methods resulted in shorter planning time (mean, 4-6.7 min), as compared with GrO (mean, 7.6 min). In terms of DVH parameters, none of the inverse methods outperformed the others. However, all inverse methods improved on compliance to the planning constraints as compared with GrO. On average, EGO-IIP and GrO resulted in highest D-90%, and the IPSA plans resulted in lowest bladder D-2.0cm3 and urethra D-1.0cm3. CONCLUSIONS: Inverse planning methods decrease planning time as compared with GrO for PDR/high-dose-rate prostate brachytherapy. DVH parameters are comparable for all methods. (C) 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:279 / 288
页数:10
相关论文
共 45 条
  • [1] Acute genitourinary toxicity after high-dose-rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: Correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity
    Akimoto, T
    Ito, K
    Saitoh, J
    Noda, S
    Harashima, K
    Sakurai, H
    Nakayama, Y
    Yamamoto, T
    Suzuki, K
    Nakano, T
    Niibe, H
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : 463 - 471
  • [2] Optimization of HDR brachytherapy dose distributions using linear programming with penalty costs
    Alterovitz, Ron
    Lessard, Etienne
    Pouliot, Jean
    Hsu, I-Chow Joe
    O'Brien, James F.
    Goldberg, Ken
    [J]. MEDICAL PHYSICS, 2006, 33 (11) : 4012 - 4019
  • [3] [Anonymous], BRACHYTHERAPY
  • [4] [Anonymous], BRACHYTHERAPY RADIUM
  • [5] [Anonymous], PRINCIPLES PRACTICE
  • [6] Baltas D., 2009, 11th International Congress of the IUPESM. World Congress on Medical Physics and Biomedical Engineering. Radiation Oncology (WC 2009), P283, DOI 10.1007/978-3-642-03474-9_81
  • [7] A LIMITED MEMORY ALGORITHM FOR BOUND CONSTRAINED OPTIMIZATION
    BYRD, RH
    LU, PH
    NOCEDAL, J
    ZHU, CY
    [J]. SIAM JOURNAL ON SCIENTIFIC COMPUTING, 1995, 16 (05) : 1190 - 1208
  • [8] Inverse planning approach for 3-D MRI-based pulse-dose rate intracavitary brachytherapy in cervix cancer
    Chajon, Enrique
    Dumas, Isabelle
    Touleimat, Mahmoud
    Magne, Nicolas
    Coulot, Jeremy
    Verstraet, Rodolfe
    Lefkopoulos, Dimitri
    Haie-Meder, Christine
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : 955 - 961
  • [9] Analysis of interaction between number of implant catheters and dose-volume histograms in prostate highdose-rate brachytherapy using a computer model
    Charra-Brunaud, C
    Hsu, ICJ
    Weinberg, V
    Pouliot, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02): : 586 - 591
  • [10] Inverse treatment planning based on MRI for HDR prostate brachytherapy
    Citrin, D
    Ning, H
    Guion, P
    Li, G
    Susil, RC
    Miller, RW
    Lessard, E
    Pouliot, J
    Huchen, X
    Capala, J
    Coleman, CN
    Camphausen, K
    Ménard, C
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (04): : 1267 - 1275