Improvements in polymer characterization by size-exclusion chromatography and liquid chromatography at the critical condition by using enhanced-fluidity liquid mobile phases with packed capillary columns

被引:28
作者
Yun, H
Olesik, SV
Marti, EH
机构
[1] Ohio State Univ, Dept Chem, Columbus, OH 43210 USA
[2] Ashland Chem Co, Ctr Tech, Dublin, OH 43017 USA
关键词
D O I
10.1021/ac971152o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microscale chromatography has found numerous applications in liquid chromatography. The combination of enhanced-fluidity liquid mobile phases with packed-capillary LC is evaluated for polymer characterization using size-exclusion chromatography (SEC) and liquid chromatography at the critical condition (LCCC) phase. Separations of polystyrene polymers and copolymers are completed using liquid chromatography at the critical condition. The critical conditions of polystyrene polymers were approached by changing the concentration of CO2 in the mixture combined with temperature and pressure variation. Because the solvent strength of enhanced-fluidity liquid mixtures is affected by temperature and pressure variation, the soh ent strength could be Long-tuned to accurately find the critical condition. Long packed capillaries could be used in this application because the enhanced-fluidity mobile phases have low viscosities. High efficiencies resulted. The performance of packed-capillary and analytical-scale analytical columns containing the same packing material was compared for a challenging separation at the critical condition.
引用
收藏
页码:3298 / 3303
页数:6
相关论文
共 30 条
[11]   CHROMATOGRAPHIC INVESTIGATIONS OF MACROMOLECULES IN THE CRITICAL RANGE OF LIQUID-CHROMATOGRAPHY .1. FUNCTIONALITY TYPE AND COMPOSITION DISTRIBUTION IN POLYETHYLENE OXIDE AND POLYPROPYLENE OXIDE COPOLYMERS [J].
GORSHKOV, AV ;
MUCH, H ;
BECKER, H ;
PASCH, H ;
EVREINOV, VV ;
ENTELIS, SG .
JOURNAL OF CHROMATOGRAPHY, 1990, 523 :91-102
[12]  
GORSHKOV AV, 1985, ZH FIZ KHIM+, V59, P958
[13]  
Hoffmann S., 1989, J MICROCOLUMN SEP, V1, P35
[14]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING FLEXIBLE FUSED-SILICA MICROPACKED COLUMNS [J].
ISHII, D ;
TAKEUCHI, T .
JOURNAL OF CHROMATOGRAPHY, 1983, 255 (JAN) :349-358
[15]   APPLICATION TO GEL PERMINATION CHROMATOGRAPHY OF MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
JINNO, K ;
NISHIHARA, M .
ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1980, 13 (08) :673-681
[16]  
KEVER EE, 1982, VYSOKOMOLEK SOED B, V24, P403
[17]   DETERMINATION OF MOLECULAR-WEIGHT DISTRIBUTION OF POLYMERS BY MICROCOLUMN EXCLUSION CHROMATOGRAPHY [J].
KEVER, JJ ;
BELENKII, BG ;
GANKINA, ES ;
VILENCHIK, LZ ;
KURENBIN, OI ;
ZHMAKINA, TP .
JOURNAL OF CHROMATOGRAPHY, 1981, 207 (01) :145-147
[18]  
KEVER JJ, 1981, J HIGH RES CHROMATOG, V4, P425
[19]   COMPARISON OF ENHANCED FLUIDITY AND ELEVATED-TEMPERATURE MOBILE PHASES IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
LEE, ST ;
OLESIK, SV .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :4498-4506
[20]  
MALIK A, 1993, J MICROCOLUMN SEP, V67, P647