Comparison of experimental and calculated peak shapes for three cylindrical geometry FAIMS prototypes of differing electrode diameters

被引:40
作者
Guevremont, R [1 ]
Purves, R [1 ]
机构
[1] Ionalyt Corp, Ottawa, ON K1A 0R6, Canada
关键词
D O I
10.1016/j.jasms.2004.11.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-field asymmetric waveform ion mobility spectrometry (FAIMS) separates ions at atmospheric pressure and room temperature based on the difference of the mobility of ions in strong electric fields and weak electric fields. This field-dependent mobility of an ion is reflected in the compensation voltage (CV) at which the ion is transmitted through FAIMS, at a given asymmetric waveform dispersion voltage (DV). Experimental CV, relative peak ion intensity, and peak width data were compared for three FAIMS prototypes with concentric cylindrical electrodes having inner/outer electrode radii of: (1) 0.4/0.6 cm, (2) 0.8/1.0 cm, and (3) 1.2/1.4 cm. The annular analyzer space was 0.2 cm wide in each case. A finite-difference numerical computation method is described for evaluation of peak shapes and widths in a CV spectrum collected using cylindrical geometry FAIMS devices. Simulation of the radial distribution of the ion density in the FAIMS analyzer is based upon calculation of diffusion, electric fields, and the electric fields introduced by coulombic ion-ion repulsion. Excellent agreement between experimental and calculated peak shapes were obtained for electrodes of wide diameter and for ions transmitted at low CV. (J Am Soc Mass Spectrom 2005, 16, 349-362) (C) 2004 American Society for Mass Spectrometry.
引用
收藏
页码:349 / 362
页数:14
相关论文
共 31 条
[1]  
Abbott M.B., 1989, COMPUTATIONAL FLUID
[2]   Evaluation of carrier gases for use in high-field asymmetric waveform ion mobility spectrometry [J].
Barnett, DA ;
Ells, B ;
Guevremont, R .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (12) :1125-1133
[3]  
Barnett DA, 2000, J MASS SPECTROM, V35, P976, DOI 10.1002/1096-9888(200008)35:8<976::AID-JMS25>3.0.CO
[4]  
2-Q
[5]   Separation of β2-microglobulin conformers by high-field asymmetric waveform ion mobility spectrometry (FAIMS) coupled to electrospray ionisation mass spectrometry [J].
Borysik, AJH ;
Read, P ;
Little, DR ;
Bateman, RH ;
Radford, SE ;
Ashcroft, AE .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (19) :2229-2234
[6]   A NEW METHOD OF SEPARATION OF MULTI-ATOMIC IONS BY MOBILITY AT ATMOSPHERIC-PRESSURE USING A HIGH-FREQUENCY AMPLITUDE-ASYMMETRIC STRONG ELECTRIC-FIELD [J].
BURYAKOV, IA ;
KRYLOV, EV ;
NAZAROV, EG ;
RASULEV, UK .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 128 (03) :143-148
[7]  
CARNAHAN BL, 1995, Patent No. 5420424
[8]   Separation of ions from explosives in differential mobility spectrometry by vapor-modified drift gas [J].
Eiceman, GA ;
Krylov, EV ;
Nazarov, EG ;
Miller, RA .
ANALYTICAL CHEMISTRY, 2004, 76 (17) :4937-4944
[9]   Trace level determination of perchlorate in water matrices and human urine using ESI-FAIMS-MS [J].
Ells, B ;
Barnett, DA ;
Purves, RW ;
Guevremont, R .
JOURNAL OF ENVIRONMENTAL MONITORING, 2000, 2 (05) :393-397
[10]   Detection of nine chlorinated and brominated haloacetic acids at part-per-trillion levels using ESI-FAIMS-MS [J].
Ells, B ;
Barnett, DA ;
Purves, RW ;
Guevremont, R .
ANALYTICAL CHEMISTRY, 2000, 72 (19) :4555-4559