Application of Sacrificial Point Anode for Prevention of Steel Corrosion in Cracked Concrete

被引:5
作者
Caronge, Muhammad Akbar [1 ]
Hamada, Hidenori [2 ]
Irmawaty, Rita [3 ]
Sagawa, Yasutaka [2 ]
Yamamoto, Daisuke [2 ]
机构
[1] Kyushu Univ, Grad Sch Engn, Fukuoka, Japan
[2] Kyushu Univ, Dept Civil Engn, Fukuoka, Japan
[3] Hasanuddin Univ, Dept Civil Engn, Makassar, Indonesia
关键词
CATHODIC PROTECTION;
D O I
10.3151/jact.13.479
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effectiveness of a commercially available sacrificial point anode for corrosion prevention of steel in cracked concrete is presented. Reinforced concrete prisms with dimensions of 150 mm x 150 mm x 500 mm were prepared with a water to cement ratio (W/C) of 0.4 showing crack widths ranging from 0.1 to 0.4 mm obtained by pre-cracking. These specimens were exposed to three conditions: (1) laboratory air (temperature of 20 +/- 2 degrees C and relative humidity of 60%); (2) immersed in 3% NaCl solution; and (3) dry/wet cycles of above mentioned conditions. Measurements included the free corrosion potential, polarization behavior of the sacrificial point anode, anodic-cathodic polarization curve of the reinforcement steel and visual observation. The test results show that the sacrificial point anode was effective to prevent the embedded steel from corrosion in cracked concrete. Specimens exposed to dry/wet cycles or immersed in 3% NaCl solution demonstrated a better protection than those exposed to laboratory air due to the high moisture condition. Thus, a sacrificial point anode becomes active to protect the steel bars even in cracked concrete.
引用
收藏
页码:479 / 488
页数:10
相关论文
共 50 条
[41]   Steel corrosion rates in concrete in contact to sea water [J].
Andrade, Carmen .
CEMENT AND CONCRETE RESEARCH, 2023, 165
[42]   Technological transition of corrosion prevention for marine steel structures [J].
Abe M. .
Zairyo to Kankyo/ Corrosion Engineering, 2011, 60 (01) :3-8
[43]   Effect of environmental pressure on the corrosion behavior of sacrificial anode magnesium alloy in simulated cementing cement hole solution [J].
Huang, Jufeng ;
Liu, Jie ;
Feng, Zhenliang .
JOURNAL OF MATERIALS SCIENCE, 2024, 59 (26) :12092-12110
[44]   Performance of zinc sacrificial anode in reinforced cement concrete members under chloride intrusion and marine environment exposure [J].
Karthikeyan, Aravindh ;
Muthusamy, Shanmugasundaram .
MATERIA-RIO DE JANEIRO, 2024, 29 (04)
[45]   Effectiveness of a conductive cementitious mortar anode for cathodic protection of steel in concrete [J].
Bertolini, L ;
Bolzoni, F ;
Pastore, T ;
Pedeferri, P .
CEMENT AND CONCRETE RESEARCH, 2004, 34 (04) :681-694
[46]   Analytical evaluation of galvanic anode cathodic protection systems for steel in concrete [J].
Hartt, WH .
CORROSION, 2002, 58 (06) :513-518
[47]   Zinc-Rich Paint As Anode for Cathodic Protection of Steel in Concrete [J].
Das, Sunil C. ;
Pouya, Homayoon Sadeghi ;
Ganjian, Eshmaiel .
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2015, 27 (11)
[48]   Corrosion prevention and remediation strategies for reinforced concrete coastal bridges [J].
Cramer, SD ;
Covino, BS ;
Bullard, SJ ;
Holcomb, GR ;
Russell, JH ;
Nelson, FJ ;
Laylor, HM ;
Soltesz, SM .
CEMENT & CONCRETE COMPOSITES, 2002, 24 (01) :101-117
[49]   Effectiveness of the cathodic protection of steel in concrete using the galvanized anode system [J].
Otani, Shunsuke ;
Yoshida, Takahiro ;
Ebina, Hitomi ;
Tsukamoto, Hideaki ;
Shinoda, Yoshio .
Zairyo to Kankyo/ Corrosion Engineering, 2015, 64 (10) :462-465
[50]   ?Electrons-siphoning? of sulfate reducing bacteria biofilm induced sharp depletion of Al--Zn--In--Mg--Si sacrificial anode in the galvanic corrosion coupled with carbon steel [J].
Zhang, Tiansui ;
Wang, Zhengyun ;
Qiu, Yubing ;
Iftikhar, Tayyaba ;
Liu, Hongfang .
CORROSION SCIENCE, 2023, 216