摘要
A flow injection (FI) system for the on-line determination of uranium in environmental samples has been characterized and tested. The simple Fl manifold uses off-the-shelf components to precisely manipulate the carrier, sample, eluent, and washing streams through a column separation module. The separation module preconcentrates the sample by a factor of 30 and removes the potentially interfering environmental matrix. TRU(TM), a commercially available resin for extraction chromatography, is packed into a glass separation column (5 X 50 mm) in the limited dispersion (D = 2.8) FI system. Detection is performed by using inductively coupled plasma mass spectrometry (ICP-MS). Results are presented for the U-238 in groundwater samples. The total analysis time for each 5.0-ml aqueous sample is 6 min. The determination of detection limit for U-238 is 0.30 ng/l. By using certified groundwater samples, a precision of 1.1% (n = 4) and accuracy of +/-1.8% for U-238 at 62.6 ng/l were observed. We also report the design and preliminary testing of a second FI-ICP-MS system that minimizes the influence of polyatomic ions (e.g., (UH+)-U-238) On the determination of minor actinides (e.g., Pu-239(+)) by ICP-MS.
引用
收藏
页码:135 / 143
页数:9
相关论文
共 50 条
  • [41] Comparison of Analytical Methods for the Determination of Uranium in Seawater Using Inductively Coupled Plasma Mass Spectrometry
    Wood, Jordana R.
    Gill, Gary A.
    Kuo, Li-Jung
    Strivens, Jonathan E.
    Choe, Key-Young
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2016, 55 (15) : 4344 - 4350
  • [42] Determination of Trace Uranium in Nuclear Grade Sponge Zirconium by Inductively Coupled Plasma Mass Spectrometry
    Liao Z.
    Long S.
    Wang P.
    An S.
    Luo F.
    Qiao H.
    Hedongli Gongcheng/Nuclear Power Engineering, 2019, 40 (03): : 57 - 60
  • [43] DETERMINATION OF THORIUM AND URANIUM IN TOTAL DIET SAMPLES BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    SHIRAISHI, K
    TAKAKU, Y
    YOSHIMIZU, K
    IGARASHI, Y
    MASUDA, K
    MCINROY, JF
    TANAKA, G
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (04) : 335 - 338
  • [44] Production date determination of uranium-oxide materials by inductively coupled plasma mass spectrometry
    Varga, Zsolt
    Suranyi, Gergely
    ANALYTICA CHIMICA ACTA, 2007, 599 (01) : 16 - 23
  • [45] Waste reduction in inductively coupled plasma mass spectrometry using flow injection and a direct injection nebulizer
    Crain, JS
    Kiely, JT
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (07) : 525 - 527
  • [46] Direct measurement of uranium in seawater by inductively coupled plasma mass spectrometry
    Qiao, Jixin
    Xu, Yihong
    TALANTA, 2018, 183 : 18 - 23
  • [47] Depleted uranium analysis in blood by inductively coupled plasma mass spectrometry
    Todorov, Todor I.
    Xu, Hanna
    Ejnik, John W.
    Mullick, Florabel G.
    Squibb, Katherine
    McDiarmid, Melissa A.
    Centeno, Jose A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (02) : 189 - 193
  • [48] Determination of Hg and Pb in Fuels by Inductively Coupled Plasma Mass Spectrometry Using Flow Injection Chemical Vapor Generation
    Chen, Feng-yi
    Jiang, Shiuh-Jen
    ANALYTICAL SCIENCES, 2009, 25 (12) : 1471 - 1476
  • [50] Automated flow injection system using extraction chromatography for the determination of plutonium in urine by inductively coupled plasma mass spectrometry
    Lariviere, Dominic
    Cumming, Thomas A.
    Kiser, Stephen
    Li, Chunsheng
    Cornett, R. Jack
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (03) : 352 - 360