Peripherally inserted central catheter with intracavitary electrocardiogram guidance: Malposition risk factors and indications for post-procedural control

被引:17
作者
Monard, Celine [1 ,2 ]
Lefevre, Mathilde [1 ]
Subtil, Fabien [2 ,3 ,4 ]
Piriou, Vincent [1 ,2 ]
David, Jean-Stephane [1 ,2 ]
机构
[1] Hosp Civils Lyon, Dept Anesthesie Reanimat, Ctr Hosp Lyon Sud, Lyon, France
[2] Univ Claude Bernard Lyon 1, Lyon, France
[3] Hosp Civils Lyon, Serv Biostat, Lyon, France
[4] CNRS, UMR5558, Lab Biometrie & Biol Evolut, Villeurbanne, France
关键词
Central venous catheter; intracavitary electrocardiogram; peripherally inserted central catheter; electrocardiography; tip location; X-ray; CENTRAL VENOUS CATHETERS; TIP; PLACEMENT; ECG; LANDMARKS; POSITION;
D O I
10.1177/1129729818781266
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives: To confirm the feasibility of intracavitary electrocardiogram guidance to verify tip's position during insertion of peripherally inserted central catheter and to identify clinical factors or intracavitary electrocardiogram patterns associated with aberrant tip's position. Methods: A prospective study was conducted in our university hospital after authorization of the ethics committee. All patients addressed for peripherally inserted central catheter insertion were included and received the insertion using intracavitary electrocardiogram and electromagnetic guidance. Side of insertion and three electrocardiogram factors were collected: visualization of P-wave at baseline (sinusal rhythm), acquisition of the maximal P-wave and the negative deflection. All patients had a systematic post-procedural chest X-ray. One of the investigators assessed all chest X-ray, blinded to the results of intracavitary electrocardiogram, and confirmed whether the tip's position on chest X-ray matched with the intracavitary electrocardiogram information or if the tip was malpositioned on chest X-ray (mismatch with intracavitary electrocardiogram or aberrant position). Factors associated with malposition were described. Results: From January 2015 to April 2015, 330 patients were eligible, 5 had an uninterpretable chest X-ray, and 14 were non-sinusal at baseline. Our main analysis population included 311 patients. We observed a mismatch between intracavitary electrocardiogram and chest X-ray estimate of the tip's position in 3 cases (1%) and an aberrant tip's position occurred in 3 cases (1%). Incidence of malposition was higher in the group of patients with non-sinusal rhythm (14%) and when the catheter was inserted on the left side (7%). Conclusion: This study confirmed the feasibility of intracavitary electrocardiogram for peripherally inserted central catheter positioning and the limits of chest X-ray. Insertion on left side may represent risk factor for aberrant position but our study lacked power to establish a statistical link.
引用
收藏
页码:128 / 133
页数:6
相关论文
共 22 条
  • [1] MRI of central venous anatomy - Implications for central venous catheter insertion
    Aslamy, Z
    Dewald, CL
    Heffner, JE
    [J]. CHEST, 1998, 114 (03) : 820 - 826
  • [2] Central venous catheterization and fatal cardiac tamponade
    Booth, SA
    Norton, B
    Mulvey, DA
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2001, 87 (02) : 298 - 302
  • [3] Catheter tip position as a risk factor for thrombosis associated with the use of subcutaneous infusion ports
    Caers, J
    Fontaine, C
    Vinh-Hung, V
    De Mey, J
    Ponnet, G
    Oost, C
    Lamote, J
    De Greve, J
    Van Camp, B
    Lacor, P
    [J]. SUPPORTIVE CARE IN CANCER, 2005, 13 (05) : 325 - 331
  • [4] Accurate central venous port-A catheter placement: intravenous electrocardiography and surface landmark techniques compared by using transesophageal echocardiography
    Chu, KS
    Hsu, JH
    Wang, SS
    Tang, CS
    Cheng, KI
    Wang, CK
    Wu, JR
    [J]. ANESTHESIA AND ANALGESIA, 2004, 98 (04) : 910 - 914
  • [5] Sherlock 3CG® Tip Confirmation System for Placement of Peripherally Inserted Central Catheters: A NICE Medical Technology Guidance
    Dale, Megan
    Higgins, Ailish
    Carolan-Rees, Grace
    [J]. APPLIED HEALTH ECONOMICS AND HEALTH POLICY, 2016, 14 (01) : 41 - 49
  • [6] Is ECG-guidance a helpful method to correctly position a central venous catheter during prehospital emergency care?
    David, JS
    Tazarourte, K
    Perfus, JP
    Savary, D
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2005, 49 (07) : 1010 - 1014
  • [7] Topographic analysis and evaluation of anatomical landmarks for placement of central venous catheters based on conventional chest X-ray and computed tomography
    Dulce, M.
    Steffen, I. G.
    Preuss, A.
    Renz, D. M.
    Hamm, B.
    Elgeti, T.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2014, 112 (02) : 265 - 271
  • [8] ENGELHARDT W, 1989, ANAESTHESIST, V38, P476
  • [9] The accuracy of electrocardiogram-controlled central line placement
    Gebhard, Ralf E.
    Szmuk, Peter
    Pivalizza, Evan G.
    Melnikov, Vladimir
    Vogt, Christianne
    Warters, Robert D.
    [J]. ANESTHESIA AND ANALGESIA, 2007, 104 (01) : 65 - 70
  • [10] Gorski Lisa A, 2017, Home Healthc Now, V35, P10