Recommendations to reduce hand exposure for standard nuclear medicine procedures

被引:16
作者
Sans-Merce, M. [1 ,2 ]
Ruiz, N. [1 ,2 ]
Barth, I.
Carnicer, A. [3 ]
Donadille, L.
Ferrari, P.
Fulop, M. [4 ]
Ginjaume, M. [3 ]
Gualdrini, G. [4 ]
Krim, S.
Mariotti, F. [4 ]
Ortega, X. [3 ]
Rimpler, A.
Vanhavere, F.
Baechler, S. [1 ,2 ]
机构
[1] Univ Hosp Ctr CHUV, Inst Radiat Phys, CH-1007 Lausanne, Switzerland
[2] Univ Lausanne, CH-1007 Lausanne, Switzerland
[3] Univ Politecn Cataluna, E-08028 Barcelona, Spain
[4] Slovak Med Univ, Bratislava, Slovakia
关键词
Skin dose; Hand exposure; Hand dose; Hand monitoring; Extremity dosimetry; Nuclear medicine; Recommendations; RADIATION; WORKERS;
D O I
10.1016/j.radmeas.2011.07.011
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The optimization of the extremity dosimetry of medical staff in nuclear medicine was the aim of the Work Package 4 (WP4) of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Programme. Hand doses and dose distributions across the hands of medical staff working in nuclear medicine departments were evaluated through an extensive measurement program involving 32 hospitals in Europe and 139 monitored workers. The study included the most frequently used radionuclides, Tc-99m- and F-18-labelled radiopharmaceuticals for diagnostic and Y-90-labelled Zevalin (R) and DOTATOC for therapy. Furthermore, Monte Carlo simulations were performed in different predefined scenarios to evaluate separately the efficacy of different radiation protection measures by comparing hand dose distributions according to various parameters. The present work gives recommendations based on results obtained with both measurements and simulations. This results in nine practical recommendations regarding the positioning of the dosemeters for an appropriate skin dose monitoring and the best protection means to reduce the personnel exposure. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1330 / 1333
页数:4
相关论文
共 12 条
  • [1] [Anonymous], 2005, MCNP-X TM User's Manual
  • [2] Hand exposure in diagnostic nuclear medicine with 18F- and 99mTc-labelled radiopharmaceuticals - Results of the ORAMED project
    Carnicer, A.
    Sans-Merce, M.
    Baechler, S.
    Barth, I.
    Donadille, L.
    Ferrari, P.
    Fulop, M.
    Ginjaume, M.
    Gualdrini, G.
    Krim, S.
    Mariotti, M.
    Ortega, X.
    Rimpler, A.
    Ruiz, N.
    Vanhavere, F.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (11) : 1277 - 1282
  • [3] Hand exposure in nuclear medicine workers
    Chruscielewski, W
    Olszewski, J
    Jankowski, J
    Cygan, A
    [J]. RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 229 - 232
  • [4] Main results of the Monte Carlo studies carried out for nuclear medicine practices within the ORAMED project
    Ferrari, P.
    Sans-Merce, M.
    Carnicer, A.
    Donadille, L.
    Fulop, M.
    Ginjaume, M.
    Gualdrini, G.
    Mariotti, F.
    Ruiz, N.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (11) : 1287 - 1290
  • [5] ICRP-International Commission on Radiological Protection, 2007, ANN ICRP, V37
  • [6] International Commission on Radiological Protection (ICRP), 2008, ANN ICRP, V38
  • [7] EXTREMITY EXPOSURE IN NUCLEAR MEDICINE: PRELIMINARY RESULTS OF A EUROPEAN STUDY
    Merce, M. Sans
    Ruiz, N.
    Barth, I.
    Carnicer, A.
    Donadille, L.
    Ferrari, P.
    Fulop, M.
    Ginjaume, M.
    Gualdrini, G.
    Krim, S.
    Mariotti, F.
    Ortega, X.
    Rimpler, A.
    Vanhavere, F.
    Baechler, S.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 515 - 520
  • [8] Extremity exposure in nuclear medicine therapy with 90Y-labelled substances - Results of the ORAMED project
    Rimpler, A.
    Barth, I.
    Ferrari, P.
    Baechler, S.
    Carnicer, A.
    Donadille, L.
    Fulop, M.
    Ginjaume, M.
    Mariotti, M.
    Sans-Merce, M.
    Gualdrini, G.
    Krim, S.
    Ortega, X.
    Ruiz, N.
    Vanhavere, F.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (11) : 1283 - 1286
  • [9] Task-specific monitoring of nuclear medicine technologists' radiation exposure
    Smart, R
    [J]. RADIATION PROTECTION DOSIMETRY, 2004, 109 (03) : 201 - 209
  • [10] An overview on extremity dosimetry in medical applications
    Vanhavere, F.
    Carinou, E.
    Donadille, L.
    Ginjaume, M.
    Jankowski, J.
    Rimpler, A.
    Merce, M. Sans
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 350 - 355