Modulation transfer function and optical quality after bilateral implantation of a+3.00 D versus a+4.00 D multifocal intraocular lens

被引:28
作者
Santhiago, Marcony R. [1 ,2 ]
Wilson, Steven E. [1 ]
Netto, Marcelo V. [2 ]
Ghanen, Ramon C. [2 ]
Monteiro, Mario Luis R. [2 ]
Bechara, Samir J. [2 ]
Espana, Edgar M. [1 ]
Mello, Glauco R. [1 ]
Kara-Junior, Newton [2 ]
机构
[1] Cleveland Clin Fdn, Cole Eye Inst, Cleveland, OH 44195 USA
[2] Univ Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
关键词
VISUAL FUNCTION; DIOPTER ADDITION; CATARACT-SURGERY; WAVE-ABERRATION; OUTCOMES; PERFORMANCE; ACUITY; MULTICENTER; EXTRACTION; VISION;
D O I
10.1016/j.jcrs.2011.08.029
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING: Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil. DESIGN: Prospective randomized double-masked comparative clinical trial. METHODS: One year after bilateral implantation of Acrysof Restor SN6AD1 +3.00 D IOLs or Acrysof Restor SN6AD3 +4.00 D IOLs, optical quality was evaluated by analyzing the in vivo modulation transfer function (MTF) and point-spread function (expressed as Strehl ratio). The Strehl ratio and MTF curve with a 4.0 pupil and a 6.0 mm pupil were measured by dynamic retinoscopy aberrometry. The uncorrected and corrected distance visual acuities at 4 m, uncorrected and distance-corrected near visual acuities at 40 cm, and uncorrected and distance-corrected intermediate visual acuities at 50 cm, 60 cm, and 70 cm were measured. RESULTS: Both IOL groups comprised 40 eyes of 20 patients. One year postoperatively, there were no statistically significant between-group differences in the MTF or Strehl ratio with either pupil size. There were no statistically significant between-group differences in distance or near visual acuity. Intermediate visual acuity was significantly better in the +3.00 D IOL group. CONCLUSION: Results indicate that the improvement in intermediate vision in eyes with the aspheric multifocal +3.00 D add IOL occurred without decreasing optical quality over that with the previous version IOL with a +4.00 D add.
引用
收藏
页码:215 / 220
页数:6
相关论文
共 28 条
[1]   Intermediate visual function with different multifocal intraocular lens models [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Puchades, Cristina ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (05) :733-739
[2]   Visual function after implantation of an aspheric bifocal intraocular lens [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Amhaz, Hussein ;
Montes-Mico, Robert ;
Valcarcel, Beatriz ;
Ferrer-Blasco, Teresa .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05) :885-892
[3]   Visual acuity comparison of 2 models of bifocal aspheric intraocular lenses [J].
Alfonso, Jose F. ;
Puchades, Cristina ;
Fernandez-Vega, Luis ;
Montes-Mico, Robert ;
Valcarcel, Beatriz ;
Ferrer-Blasco, Teresa .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04) :672-676
[4]   Optics of aberroscopy and super vision [J].
Applegate, RA ;
Thibos, LN ;
Hilmantel, G .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (07) :1093-1107
[5]   Can we measure wave aberration in patients with diffractive 10Ls? [J].
Charman, W. Neil ;
Montes-Mico, Robert ;
Radhakrishnan, Hema .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11) :1997-1997
[6]  
Chiam PJT, 2006, J CATARACT REFR SURG, V32, P1987
[7]   ReSTOR intraocular lens implantation in cataract surgery: Quality of vision [J].
Chiam, Patrick J. T. ;
Chan, Jin H. ;
Aggarwal, Rajesh K. ;
Kasaby, Sam .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (09) :1459-1463
[8]   Intermediate visual acuity without spectacles following bilateral ReSTOR® implantation [J].
Cuq, C. ;
Spera, C. ;
Laurendeau, C. ;
Lafuma, A. ;
Berdeaux, G. .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2008, 18 (05) :733-738
[9]   History and development of the apodized diffractive intraocular lens [J].
Davison, James A. ;
Simpson, Michael J. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05) :849-858
[10]   Visual outcomes after cataract surgery with implantation of a+3.00 D or+4.00 D aspheric diffractive multifocal intraocular lens: Comparative study [J].
de Vries, Niels E. ;
Webers, Carroll A. B. ;
Montes-Mico, Robert ;
Ferrer-Blasco, Teresa ;
Nuijts, Rudy M. M. A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (08) :1316-1322