Characterization of extracellular vesicles by flow cytometry: Challenges and promises

被引:17
作者
Gul, Banat [1 ]
Syed, Feryal [2 ]
Khan, Shamim [3 ]
Iqbal, Abid [4 ]
Ahmad, Iftikhar [5 ]
机构
[1] Natl Univ Sci & Technol NUST, Islamabad, Pakistan
[2] Nishtar Inst Dent Multan, Multan, Pakistan
[3] Islamia Coll Peshawar, Dept Phys, Khyber Pakhtunkhwa, Pakistan
[4] Univ Engn & Technol Peshawar, Dept Elect Engn, Jalozai Campus, Peshawar, Pakistan
[5] Inst Radiotherapy & Nucl Med IRNUM, Peshawar, Pakistan
关键词
Extracellular vesicles; Flow cytometry; Light scattering; Reference beads; Fluorescence; Liquid biopsy; QUANTITATING FLUORESCENCE INTENSITY; CALIBRATED POLYSTYRENE BEADS; REFRACTIVE-INDEX; LIGHT-SCATTERING; MICROPARTICLES; SENSITIVITY; RESOLUTION; SUBPOPULATIONS; MICROVESICLES; LIMITATIONS;
D O I
10.1016/j.micron.2022.103341
中图分类号
TH742 [显微镜];
学科分类号
摘要
The International Society for Extracellular Vesicles (ISEV) defines the extracellular vesicle (EV) as "the particles naturally released from the cell that are delimited by a lipid bilayer and cannot replicate, i.e. do not contain a functional nucleus". The size (diameter) of EVs ranges in-30-1000 nm, with peak population at -100 nm. Flow cytometry (FCM) is the most commonly used technique for analysis of EVs. However, accurate characterization, procedure standardization, instrument calibration and results interpretation/validation of EVs is confounded by their complex and variable composition, small size and substantial differences in physiological concentrations. Here, the challenges to and promises of FCM for characterization of EVs are discussed. Specifically, we sys-tematically reviewed the pitfalls of FCM in the detection of (small) EVs and the corresponding strategies for enhancing the sensitivity and resolution of the instrument. The shortcomings and improvement in the overall FCM system are described in terms of reference material for calibration, the collection optics for fluorescence (FL), side scatter (SSC) and forward scatter (FSC) signals and fluidics. This study may provide a comprehensive reference for a brief overview pertaining to the challenges and promises of a modern FCM system for analysis of EVs.
引用
收藏
页数:9
相关论文
共 140 条
  • [1] Isolation and characterization of platelet-derived extracellular vesicles
    Aatonen, Maria T.
    Ohman, Tiina
    Nyman, Tuula A.
    Laitinen, Saara
    Gronholm, Mikaela
    Siljander, Pia R. -M.
    [J]. JOURNAL OF EXTRACELLULAR VESICLES, 2014, 3 (01)
  • [2] Flow cytometry: basic principles and applications
    Adan, Aysun
    Alizada, Gunel
    Kiraz, Yagmur
    Baran, Yusuf
    Nalbant, Ayten
    [J]. CRITICAL REVIEWS IN BIOTECHNOLOGY, 2017, 37 (02) : 163 - 176
  • [3] Assessment of platelet activation in several different anticoagulants by the Advia 120 Hematology System, fluorescence flow cytometry, and electron microscopy
    Ahnadi, CE
    Chapman, ES
    Lépine, M
    Okrongly, D
    Pujol-Moix, N
    Hernández, A
    Boughrassa, F
    Grant, AM
    [J]. THROMBOSIS AND HAEMOSTASIS, 2003, 90 (05) : 940 - 948
  • [4] Improved Flow Cytometric Light Scatter Detection of Submicron-Sized Particles by Reduction of Optical Background Signals
    Arkesteijn, Ger J. A.
    Lozano-Andres, Estefania
    Libregts, Sten F. W. M.
    Wauben, Marca H. M.
    [J]. CYTOMETRY PART A, 2020, 97 (06) : 610 - 619
  • [5] A simple flow cytometry method improves the detection of phosphatidylserine-exposing extracellular vesicles
    Arraud, N.
    Gounou, C.
    Linares, R.
    Brisson, A. R.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2015, 13 (02) : 237 - 247
  • [6] Extracellular vesicles from blood plasma: determination of their morphology, size, phenotype and concentration
    Arraud, N.
    Linares, R.
    Tan, S.
    Gounou, C.
    Pasquet, J. -M.
    Mornet, S.
    Brisson, A. R.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2014, 12 (05) : 614 - 627
  • [7] Fluorescence Triggering: A General Strategy for Enumerating and Phenotyping Extracellular Vesicles by Flow Cytometry
    Arraud, Nicolas
    Gounou, Celine
    Turpin, Delphine
    Brisson, Alain R.
    [J]. CYTOMETRY PART A, 2016, 89A (02) : 184 - 195
  • [8] Procoagulant and platelet-derived microvesicle absolute counts determined by flow cytometry correlates with a measurement of their functional capacity
    Ayers, Lisa
    Harrison, Paul
    Kohler, Malcolm
    Ferry, Berne
    [J]. JOURNAL OF EXTRACELLULAR VESICLES, 2014, 3 (01)
  • [9] Extracellular vesicles isolated from porcine seminal plasma exhibit different tetraspanin expression profiles
    Barranco, Isabel
    Padilla, Lorena
    Parrilla, Inmaculada
    Alvarez-Barrientos, Alberto
    Perez-Patino, Cristina
    Pena, Fernando J.
    Martinez, Emilio A.
    Rodriguez-Martinez, Heriberto
    Roca, Jordi
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [10] The quantitative proteome of a human cell line
    Beck, Martin
    Schmidt, Alexander
    Malmstroem, Johan
    Claassen, Manfred
    Ori, Alessandro
    Szymborska, Anna
    Herzog, Franz
    Rinner, Oliver
    Ellenberg, Jan
    Aebersold, Ruedi
    [J]. MOLECULAR SYSTEMS BIOLOGY, 2011, 7