High resolution FIB-TEM and FIB-SEM characterization of electrode/electrolyte interfaces in solid oxide fuel cells materials

被引:29
作者
Soldati, Analia L. [1 ]
Baque, Laura [1 ,2 ]
Troiani, Horacio [1 ]
Cotaro, Carlos [1 ]
Schreiber, Anja [3 ]
Caneiro, Alberto [1 ,2 ]
Serquis, Adriana [1 ,2 ]
机构
[1] CNEA CONICET, Ctr Atom Bariloche, San Carlos De Bariloche, Rio Negro, Argentina
[2] Inst Balseiro, San Carlos De Bariloche, Rio Negro, Argentina
[3] Deutsch GeoForsch Zentrum GFZ, Helmholtz Zentrum Potsdam, Sekt 3 3, D-14473 Potsdam, Germany
关键词
Interface; SOFC; FIB; Nanostructure; Semi-coherent attachment; TEM; SOFC CATHODES; MICROSTRUCTURE; RECONSTRUCTION; PERFORMANCE; TOMOGRAPHY; ELECTRODES; ANODE;
D O I
10.1016/j.ijhydene.2011.04.121
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A Focused Ion Beam (FIB)/lift-out technique was used to prepare site-specific thin samples of the cathode/electrolyte interface of Intermediate Temperature Solid Oxide Fuel Cells (IT-SOFC) materials. The cathode under study was a nanostructured perovskite of composition La(0.4)Sr(0.6)Co(0.8)Fe(0.2)O(3.delta) (LSCF) deposited by spin coating on a Ce(0.9)Gd(0.1)O(2-delta) (CGO) supporting substrate. We compared the results for a 15 mu m and a 5 mu m thickness cathode layers, before and after a thermal treatment of 1000 h at 500 degrees C, with the aim of simulating operation conditions. Both, Transmission (TEM) and Scanning (SEM) Electron Microscopy, coupled with Energy Dispersive Spectroscopy (EDS) systems, were used to characterize the composition and nanostructure at both sides of the cathode/electrolyte interface. To our knowledge, this is the first time that a semi-coherent interface between LSCF and CGO was observed by Electron Diffraction as well as by High Resolution TEM in many points at the interfacial boundary. A large difference in total contact area was observed between the thickest and the thinnest cathode layers, despite they present the same composition and nano sized structure. The real contact area in the 5 mu m cathode sample is around 50% less than in the 15 mu m sample due to the presence of pores at the interface. This observation may partially explain the difference in resistivity observed for these two half cells assemblies. On the other side, no differences were found comparing composition and nanostructure at the interface before and after the thermal treatment. Thus, this study becomes fundamental to understand the role played by the interface for improving the performance of IT-SOFC under long time operation conditions: a necessary premise for its real application. Copyright (c) 2011, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:9180 / 9188
页数:9
相关论文
共 32 条
  • [21] X-ray nano computerised tomography of SOFC electrodes using a focused ion beam sample-preparation technique
    Shearing, P. R.
    Gelb, J.
    Brandon, N. P.
    [J]. JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2010, 30 (08) : 1809 - 1814
  • [22] 3D reconstruction of SOFC anodes using a focused ion beam lift-out technique
    Shearing, P. R.
    Golbert, J.
    Chater, R. J.
    Brandon, N. P.
    [J]. CHEMICAL ENGINEERING SCIENCE, 2009, 64 (17) : 3928 - 3933
  • [23] Skinner S., 2001, Fuel Cells Bulletin, V4, P6
  • [24] Evaluation of the relationship between cathode microstructure and electrochemical behavior for SOFCs
    Smith, J. R.
    Chen, A.
    Gostovic, D.
    Hickey, D.
    Kundinger, D.
    Duncan, K. L.
    DeHoff, R. T.
    Jones, K. S.
    Wachsman, E. D.
    [J]. SOLID STATE IONICS, 2009, 180 (01) : 90 - 98
  • [25] Materials for fuel-cell technologies
    Steele, BCH
    Heinzel, A
    [J]. NATURE, 2001, 414 (6861) : 345 - 352
  • [26] WILLIAMS DB, 1996, TRANSMISSION ELECT M, P624
  • [27] Three-dimensional reconstruction of a solid-oxide fuel-cell anode
    Wilson, James R.
    Kobsiriphat, Worawarit
    Mendoza, Roberto
    Chen, Hsun-Yi
    Hiller, Jon M.
    Miller, Dean J.
    Thornton, Katsuyo
    Voorhees, Peter W.
    Adler, Stuart B.
    Barnett, Scott A.
    [J]. NATURE MATERIALS, 2006, 5 (07) : 541 - 544
  • [28] Effect of composition of (La0.8Sr0.2MnO3-Y2O3-stabilized ZrO2) cathodes: Correlating three-dimensional microstructure and polarization resistance
    Wilson, James R.
    Cronin, J. Scott
    Duong, Anh T.
    Rukes, Sherri
    Chen, Hsun-Yi
    Thornton, Katsuyo
    Mumm, Daniel R.
    Barnett, Scott
    [J]. JOURNAL OF POWER SOURCES, 2010, 195 (07) : 1829 - 1840
  • [29] Quantitative three-dimensional microstructure of a solid oxide fuel cell cathode
    Wilson, James R.
    Duong, Anh T.
    Gameiro, Marcio
    Chen, Hsun-Yi
    Thornton, Katsuyo
    Mumm, Daniel R.
    Barnett, Scott A.
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (05) : 1052 - 1056
  • [30] Focused Ion Beam (FIB) combined with SEM and TEM: Advanced analytical tools for studies of chemical composition, microstructure and crystal structure in geomaterials on a nanometre scale
    Wirth, Richard
    [J]. CHEMICAL GEOLOGY, 2009, 261 (3-4) : 217 - 229