Ultra-high resolution spectral domain optical coherence tomography using supercontinuum light source

被引:2
|
作者
Lim, Yiheng [1 ]
Yatagai, Toyohiko [1 ]
Otani, Yukitoshi [1 ]
机构
[1] Utsunomiya Univ, Utsunomiya, Tochigi 3218585, Japan
关键词
Optical coherence tomography; Supercontinuum; Spectrometer calibration; Sweat duct; HIGH-SPEED; SKIN;
D O I
10.1007/s10043-016-0197-7
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An ultra-high resolution spectral domain optical coherence tomography (SD-OCT) was developed using a cost-effective supercontinuum laser. A spectral filter consists of a dispersive prism, a cylindrical lens and a right-angle prism was built to transmit the wavelengths in range 680-940 nm to the OCT system. The SD-OCT has achieved 1.9 mu m axial resolution and the sensitivity was estimated to be 91.5 dB. A zero-crossing fringes matching method which maps the wavelengths to the pixel indices of the spectrometer was proposed for the OCT spectral calibration. A double sided foam tape as a static sample and the tip of a middle finger as a biological sample were measured by the OCT. The adhesive and the internal structure of the foam of the tape were successfully visualized in three dimensions. Sweat ducts was clearly observed in the OCT images at very high resolution. To the best of our knowledge, this is the first demonstration of ultra-high resolution visualization of sweat duct by OCT.
引用
收藏
页码:180 / 186
页数:7
相关论文
共 50 条
  • [21] High spectral power-density supercontinuum source at 1.3 μm suitable for optical coherence tomography applications
    Abrardi, L.
    Martin-Lopez, S.
    Carrasco-Sanz, A.
    Corredera, P.
    Hernanz, M. L.
    Gonzalez-Herraez, M.
    THIRD EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 2007, 6619
  • [22] Investigation on spectral-domain optical coherence tomography using a tungsten halogen lamp as light source
    Yuping Chen
    Hong Zhao
    Zhao Wang
    Optical Review, 2009, 16 : 26 - 29
  • [23] Investigation on spectral-domain optical coherence tomography using a tungsten halogen lamp as light source
    Chen, Yuping
    Zhao, Hong
    Wang, Zhao
    OPTICAL REVIEW, 2009, 16 (01) : 26 - 29
  • [24] Developmental and morphological studies in Japanese medaka with ultra-high resolution optical coherence tomography
    Gladys, Fanny Moses
    Matsuda, Masaru
    Lim, Yiheng
    Jackin, Boaz Jessie
    Imai, Takuto
    Otani, Yukitoshi
    Yatagai, Toyohiko
    Cense, Barry
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (02): : 297 - 308
  • [25] Multispectral photoacoustic microscopy and optical coherence tomography using a single supercontinuum source
    Bondu, M.
    Marques, M. J.
    Moselund, P. M.
    Lall, G.
    Bradu, A.
    Podoleanu, A.
    PHOTOACOUSTICS, 2018, 9 : 21 - 30
  • [26] In vivo characterization of extramammary Paget's disease by ultra-high cellular resolution optical coherence tomography
    Wang, Jen-Yu
    Wang, Yen-Jen
    Wu, Yu-Hung
    SKIN RESEARCH AND TECHNOLOGY, 2021, 27 (01) : 114 - 117
  • [27] Quantitative analysis of the intraretinal layers and optic nerve head using ultra-high resolution optical coherence tomography
    Wang, Yuhong
    Jiang, Hong
    Shen, Meixiao
    Lam, Byron L.
    DeBuc, Delia Cabrera
    Ye, Yufeng
    Li, Ming
    Tao, Aizhu
    Shao, Yilei
    Wang, Jianhua
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (06)
  • [28] Wavelength dependence of ultrahigh resolution optical coherence tomography using supercontinuum
    Nishizawa, Norihiko
    Yamanaka, Masahito
    Kawagoe, Hiroyuki
    Matsushima, Miyoko
    Mori, Kensaku
    Kawabe, Tsutomu
    OPTICAL BIOPSY XVIII: TOWARD REAL-TIME SPECTROSCOPIC IMAGING AND DIAGNOSIS, 2020, 11234
  • [29] Optimization of the Source Power Usage in Spectral-Domain Optical Coherence Tomography
    Wang, Yimin
    Zhang, Xiangyang
    Chen, Xiaobing
    Chen, Zhong
    IEEE PHOTONICS JOURNAL, 2017, 9 (05):
  • [30] Improvement of axial resolution for optical coherence tomography using a synthesized light source
    Sato, M
    Wakaki, I
    Watanabe, Y
    Tanno, N
    ROMOPTO 2003: SEVENTH CONFERENCE ON OPTICS, 2004, 5581 : 662 - 669