Ultra-high resolution spectral domain optical coherence tomography using supercontinuum light source

被引:2
|
作者
Lim, Yiheng [1 ]
Yatagai, Toyohiko [1 ]
Otani, Yukitoshi [1 ]
机构
[1] Utsunomiya Univ, Utsunomiya, Tochigi 3218585, Japan
关键词
Optical coherence tomography; Supercontinuum; Spectrometer calibration; Sweat duct; HIGH-SPEED; SKIN;
D O I
10.1007/s10043-016-0197-7
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An ultra-high resolution spectral domain optical coherence tomography (SD-OCT) was developed using a cost-effective supercontinuum laser. A spectral filter consists of a dispersive prism, a cylindrical lens and a right-angle prism was built to transmit the wavelengths in range 680-940 nm to the OCT system. The SD-OCT has achieved 1.9 mu m axial resolution and the sensitivity was estimated to be 91.5 dB. A zero-crossing fringes matching method which maps the wavelengths to the pixel indices of the spectrometer was proposed for the OCT spectral calibration. A double sided foam tape as a static sample and the tip of a middle finger as a biological sample were measured by the OCT. The adhesive and the internal structure of the foam of the tape were successfully visualized in three dimensions. Sweat ducts was clearly observed in the OCT images at very high resolution. To the best of our knowledge, this is the first demonstration of ultra-high resolution visualization of sweat duct by OCT.
引用
收藏
页码:180 / 186
页数:7
相关论文
共 50 条
  • [1] Ultra-high resolution spectral domain optical coherence tomography using supercontinuum light source
    Yiheng Lim
    Toyohiko Yatagai
    Yukitoshi Otani
    Optical Review, 2016, 23 : 180 - 186
  • [2] A comparative study of noise in supercontinuum light sources for ultra-high resolution Optical Coherence Tomography
    Maria, M.
    Gonzalo, I. B.
    Bondu, M.
    Engelsholm, R. D.
    Feuchter, T.
    Moselund, P. M.
    Leick, L.
    Bang, O.
    Podoleanu, A.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES X, 2017, 10056
  • [3] Ultra-low noise supercontinuum source for ultra-high resolution optical coherence tomography at 1300 nm
    Gonzalo, I. B.
    Maria, M.
    Engelsholm, R. D.
    Feuchter, T.
    Leick, L.
    Moselund, P. M.
    Podoleanu, A.
    Bang, O.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES XI, 2018, 10486
  • [4] High resolution spectral-domain optical coherence tomography using a thermal light source
    Qin, Yu-Wei
    Zhao, Hong
    Zhuang, Zhong-Qin
    Zhang, Lu
    OPTICAL AND QUANTUM ELECTRONICS, 2012, 43 (6-10) : 83 - 90
  • [5] Ultra-High Resolution Optical Coherence Tomography (OCT) Using a Halogen Lamp as the Light Source
    Masato Ohmi
    Masamitsu Haruna
    Optical Review, 2003, 10 : 478 - 481
  • [6] High resolution spectral-domain optical coherence tomography using a thermal light source
    Yu-Wei Qin
    Hong Zhao
    Zhong-Qin Zhuang
    Lu Zhang
    Optical and Quantum Electronics, 2012, 43 : 83 - 90
  • [7] Low-cost spectrometer design for ultra-high resolution spectral domain optical coherence tomography
    Chen, Chaoliang
    Pu, Yurui
    Shi, Weisong
    CHINESE OPTICS LETTERS, 2023, 21 (10)
  • [8] Quality improvement for high resolution in vivo images by spectral domain optical coherence tomography with supercontinuum source
    Szkulmowski, M
    Wojtkowski, A
    Bajraszewski, T
    Gorczynska, I
    Targowski, P
    Wasilewski, W
    Kowalczyk, A
    Radzewicz, C
    OPTICS COMMUNICATIONS, 2005, 246 (4-6) : 569 - 578
  • [9] Polarization maintaining fiber based ultra-high resolution spectral domain polarization sensitive optical coherence tomography
    Goetzinger, Erich
    Baumann, Bernhard
    Pircher, Michael
    Hitzenberger, Christoph K.
    OPTICS EXPRESS, 2009, 17 (25): : 22704 - 22717
  • [10] High Resolution Imaging System Using Spectral Domain Optical Coherence Tomography Using NIR Source
    Bhatia, Prachi
    Choudhari, Suyog
    Rodrigues, Anjana
    Pati, Mukesh
    Makkar, Roshan
    PROCEEDINGS OF THE 2016 IEEE INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS, SIGNAL PROCESSING AND NETWORKING (WISPNET), 2016, : 2212 - 2216