Quantitation of metallothionein isoforms in mouse liver on capillary zone electrophoresis

被引:16
作者
Minami, T
Tohno, Y
Okazaki, Y
Kubo, K
Otaki, N
Kimura, M
机构
[1] Nara Med Univ, Dept Anat, Cell Biol Lab, Kashihara, Nara 634, Japan
[2] Kinki Univ, Fac Pharmaceut Sci, Osaka 577, Japan
[3] Natl Inst Ind Hlth, Dept Occupat Dis, Kawasaki, Kanagawa 214, Japan
[4] Keio Univ, Sch Med, Dept Mol Biol, Tokyo 160, Japan
关键词
metallothionein; isoform; MT-1; MT-2; quantitation; capillary zone electrophoresis; polyacrylamide; carbonic anhydrase; ascorbic acid;
D O I
10.1016/S0003-2670(98)00337-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for determining concentration of metallothionein (MT) isoforms in mouse liver was established by using capillary zone electrophoresis (CZE), and carbonic anhydrase was used as an internal standard. The cytosol fraction was heated at 100 degrees C for 1 min, and the supernatant was applied directly to CZE after filtration. Both MT-1 and MT-2 isoforms were identified from the migration times of purified MT isoforms, and the peaks were definitely identified from the other peaks. In addition, carbonic anhydrase was adopted as an internal standard. Based on standard curves of purified MT isoforms, concentrations of MT isoforms in the liver were determined from the estimates of peak areas. In control mouse liver, MT-1 isoform was detected at 48.5+/-25.4 mu g/g wet weight, and MT-2 isoform was 154.0+/-39.7 mu g/g. Twenty-four hours after zinc injection, MT-1 increased to 773.7+/-374.3 mu g/g, and MT-2 was 487.2+/-207.1 mu g/g. The addition of ascorbic acid to the homogenizing medium resulted in the decrease of MT isoforms in mouse liver. From these findings, we concluded that CZE analysis using a polyacrylamide-coated tube at neutral pH makes quantitation of MT isoforms in mouse liver possible. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:241 / 247
页数:7
相关论文
共 50 条
[21]   Separation and quantitation of monoclonal antibodies in cell growth medium using capillary zone electrophoresis [J].
Dai, HJ ;
Li, G ;
Krull, IS .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (6-7) :1143-1153
[22]   Optimized determination of carbohydrate-deficient transferrin isoforms in serum by capillary zone electrophoresis [J].
Tagliaro, F ;
Crivellente, F ;
Manetto, G ;
Puppi, I ;
Deyl, Z ;
Marigo, M .
ELECTROPHORESIS, 1998, 19 (16-17) :3033-3039
[23]   CONTRIBUTION OF CAPILLARY COILING TO ZONE DISPERSION IN CAPILLARY ZONE ELECTROPHORESIS [J].
KASICKA, V ;
PRUSIK, Z ;
GAS, B ;
STEDRY, M .
ELECTROPHORESIS, 1995, 16 (11) :2034-2038
[24]   FLAT CAPILLARY ZONE ELECTROPHORESIS [J].
CHEN, Y ;
ZHU, A .
SCIENCE IN CHINA SERIES B-CHEMISTRY, 1992, 35 (06) :649-658
[25]   Capillary zone electrophoresis of proteins [J].
Dolník, V .
ELECTROPHORESIS, 1997, 18 (12-13) :2353-2361
[26]   FLAT CAPILLARY ZONE ELECTROPHORESIS [J].
陈义 ;
竺安 .
Science China Chemistry, 1992, (06) :649-658
[27]   Capillary zone electrophoresis of minocycline [J].
Li, YM ;
VanSchepdael, A ;
Roets, E ;
Hoogmartens, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (8-10) :1095-1099
[28]   Quantification of metallothionein isoforms in fish liver and its implications for biomonitoring [J].
Lacorn, M ;
Lahrssen, A ;
Rotzoll, N ;
Simat, TJ ;
Steinhart, H .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2001, 20 (01) :140-145
[29]   Quantitation in capillary electrophoresis-mass spectrometry [J].
Ohnesorge, J ;
Neusüss, C ;
Wätzig, H .
ELECTROPHORESIS, 2005, 26 (21) :3973-3987
[30]   Capillary gel electrophoresis for precise protein quantitation [J].
Cianciulli, Claudia ;
Hahne, Thomas ;
Waetzig, Hermann .
ELECTROPHORESIS, 2012, 33 (22) :3276-3280