摘要
Development of protection scheme for microgrid is a challenging issue due to the inclusion of distributed generations (DGs). The research work for developing the primary protection scheme for microgrid is progressing continuously. This paper proposes an integrated impedance angle (IIA) based protection scheme using wide-area positive sequence components of voltages and currents. The proposed scheme uses data retrieved from the phasor measurement units (PMUs) of IEEE C37.118.1 complied standards. Furthermore, the IIA for the line is computed considering both ends PMU information, which is the key indicator for identifying the faults in the microgrid. The proposed protection scheme is extensively tested considering the different operating conditions of microgrid, variation in DG penetration and variation in fault parameters such as fault resistance, fault types, and fault location. Furthermore, cross validation on no-fault situations including section cutoff, disconnection of high penetration DG, grid-islanding resynchronization, motor starting, capacitor switching, and load encroachment are carried out. The proposed scheme is also tested for the insensitivity towards the external faults. The test results on both 15-bus and 34-bus systems clearly indicate that the proposed IIA-based wide-area scheme can be a potential protection measure for microgrid under varied operating circumstances.
引用
收藏
页码:183 / 193
页数:11
相关论文
共 35 条
[1]   Performance of communication networks for Integrity protection systems based on travelling wave with IEC 61850 [J].
Ali, N. H. ;
Ali, Borhanuddin M. ;
Othman, Mohammad Lutfi ;
Abdel-Latif, K. M. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 95 :664-675
[2]  
[Anonymous], [No title captured]
[3]  
[Anonymous], [No title captured]
[4]  
[Anonymous], 2011, IEEE Standard C37.118.1a- 2014 (Amendment to IEEE Standard C37.118.1-2011), DOI DOI 10.1109/IEEESTD.2011.6111219
[5]   Distance relaying of 11Kv circuits to increase the installed capacity of distributed generation [J].
Chilvers, I ;
Jenkins, N ;
Crossley, P .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2005, 152 (01) :40-46
[6]   Impedance-Based Fault Location in Transmission Networks: Theory and Application [J].
Das, Swagata ;
Santoso, Surya ;
Gaikwad, Anish ;
Patel, Mahendra .
IEEE ACCESS, 2014, 2 :537-557
[7]   Performance of Interconnection Protection Based on Distance Relaying for Wind Power Distributed Generation [J].
El-Arroudi, Khalil ;
Joos, Geza .
IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (02) :620-629
[8]  
Falahati B., 2011, P IEEE POW EN SOC GE, P1
[9]   Locating the Source of Events in Power Distribution Systems Using Micro-PMU Data [J].
Farajollahi, Mohammad ;
Shahsavari, Alireza ;
Stewart, Emma M. ;
Mohsenian-Rad, Hamed .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (06) :6343-6354
[10]   Microgrid protection using Hilbert-Huang transform based-differential scheme [J].
Gururani, Ashika ;
Mohanty, Soumya R. ;
Mohanta, Jagadish Chandra .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (15) :3707-3716