Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT

被引:278
|
作者
Kachelriess, M
Watzke, O
Kalender, WA
机构
[1] Institute of Medical Physics, University of Erlangen-Nürnberg, Erlangen
关键词
computed tomography (CT); multi-slice spiral CT (MSCT); cone-beam CT (CBCT); artifact reduction; noise reduction; dose reduction; adaptive filters;
D O I
10.1118/1.1358303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In modern computed tomography (CT) there is a strong desire to reduce patient dose and/or to improve image quality by increasing spatial resolution and decreasing image noise. These are conflicting demands since increasing resolution at a constant noise level or decreasing noise at a constant resolution level implies a higher demand on x-ray power and an increase of patient dose. X-ray tube power is limited due to technical reasons. We therefore developed a generalized multi-dimensional adaptive filtering approach that applies nonlinear filters in up to three dimensions in the raw data domain. This new method differs from approaches in the literature since our nonlinear filters are applied not only in the detector row direction but also in the view and in the z-direction. This true three-dimensional filtering improves the quantum statistics of a measured projection Value proportional to the third power of the filter size. Resolution tradeoffs are shared among these three dimensions and thus are considerably smaller as compared to one-dimensional smoothing approaches. Patient data of spiral and sequential single- and multi-slice CT scans as well as simulated spiral cone-beam data were processed to evaluate these new approaches. Image quality was assessed by evaluation of difference images, by measuring the image noise and the noise reduction, and by calculating the image resolution using point spread functions. The use of generalized adaptive filters helps to reduce image noise or, alternatively, patient dose. Image noise structures, typically along the direction of the highest attenuation, are effectively reduced. Noise reduction values of typically 30%-60% can be achieved in noncylindrical body regions like the shoulder. The loss in image resolution remains below 5% for all cases. In addition, the new method has a great potential to reduce metal artifacts, e.g., in the hip region. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:475 / 490
页数:16
相关论文
共 50 条
  • [41] Diagnosis value of multi-slice spiral CT in renal trauma
    Peng, Naixiong
    Wang, Xisheng
    Zhang, Zejian
    Fu, Shui
    Fan, Jiqing
    Zhang, Yuanyuan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (05) : 649 - 655
  • [42] Dynamic reconstruction of the lung using multi-slice spiral CT
    Wang, G
    Hoffman, EA
    Heuscher, DJ
    Chandra, S
    RADIOLOGY, 2000, 217 : 565 - 565
  • [43] Diagnostic value of multi-slice spiral CT in aortic dissection
    刘昌伟
    黄向明
    符水
    South China Journal of Cardiology, 2010, 11 (04) : 234 - 237
  • [44] Temporal resolution of multi-slice spiral CT with subsecond scanning
    Liang, Y
    Kopecky, KK
    Ruimi, D
    RADIOLOGY, 1998, 209P : 284 - 285
  • [45] Isotropic high-resolution in multi-slice spiral CT
    Shechter, G
    Altman, A
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3769 - 3772
  • [46] Multi-slice spiral CT findings of tubulovillous adenoma of the duodenum
    Li, Li-Chao
    Zheng, Li-Rong
    Han, Ning
    CLINICAL IMAGING, 2022, 82 : 135 - 138
  • [47] Multi-slice spiral CT findings of tubulovillous adenoma of the duodenum
    Li, Li-Chao
    Zheng, Li-Rong
    Han, Ning
    Clinical Imaging, 2022, 82 : 135 - 138
  • [48] Stereotactic Localization: From Single-Slice to Multi-Slice Registration Including a Novel Solution for Parallel Bipanels
    Sedrak, Mark
    Bruna, Andres E.
    Alaminos-Bouza, Armando L.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [49] Correction of head movements in multi-slice EPI and single-slice gradient-echo functional MRI
    Singh, M
    Al-Dayeh, L
    Patel, P
    Kim, T
    Guclu, C
    Nalcioglu, O
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1354 - 1356
  • [50] Single-slice versus multi-slice display for human-observer lesion-detection studies
    Wells, RG
    King, MA
    Gifford, HC
    Pretorius, PH
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 910 - 914