Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT

被引:278
|
作者
Kachelriess, M
Watzke, O
Kalender, WA
机构
[1] Institute of Medical Physics, University of Erlangen-Nürnberg, Erlangen
关键词
computed tomography (CT); multi-slice spiral CT (MSCT); cone-beam CT (CBCT); artifact reduction; noise reduction; dose reduction; adaptive filters;
D O I
10.1118/1.1358303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In modern computed tomography (CT) there is a strong desire to reduce patient dose and/or to improve image quality by increasing spatial resolution and decreasing image noise. These are conflicting demands since increasing resolution at a constant noise level or decreasing noise at a constant resolution level implies a higher demand on x-ray power and an increase of patient dose. X-ray tube power is limited due to technical reasons. We therefore developed a generalized multi-dimensional adaptive filtering approach that applies nonlinear filters in up to three dimensions in the raw data domain. This new method differs from approaches in the literature since our nonlinear filters are applied not only in the detector row direction but also in the view and in the z-direction. This true three-dimensional filtering improves the quantum statistics of a measured projection Value proportional to the third power of the filter size. Resolution tradeoffs are shared among these three dimensions and thus are considerably smaller as compared to one-dimensional smoothing approaches. Patient data of spiral and sequential single- and multi-slice CT scans as well as simulated spiral cone-beam data were processed to evaluate these new approaches. Image quality was assessed by evaluation of difference images, by measuring the image noise and the noise reduction, and by calculating the image resolution using point spread functions. The use of generalized adaptive filters helps to reduce image noise or, alternatively, patient dose. Image noise structures, typically along the direction of the highest attenuation, are effectively reduced. Noise reduction values of typically 30%-60% can be achieved in noncylindrical body regions like the shoulder. The loss in image resolution remains below 5% for all cases. In addition, the new method has a great potential to reduce metal artifacts, e.g., in the hip region. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:475 / 490
页数:16
相关论文
共 50 条
  • [31] Investigation of the 3-dimensional spatial resolution of multi-slice spiral CT
    Fuchs, TO
    Krause, JU
    Kalender, WA
    RADIOLOGY, 2000, 217 : 565 - 565
  • [32] Imaging skeletal anatomy of injured cervical spine specimens: comparison of single-slice vs multi-slice helical CT
    Obenauer, S
    Alamo, L
    Herold, T
    Funke, M
    Kopka, L
    Grabbe, E
    EUROPEAN RADIOLOGY, 2002, 12 (08) : 2107 - 2111
  • [33] Imaging skeletal anatomy of injured cervical spine specimens: comparison of single-slice vs multi-slice helical CT
    S. Obenauer
    L. Alamo
    T. Herold
    M. Funke
    L. Kopka
    E. Grabbe
    European Radiology, 2002, 12 : 2107 - 2111
  • [34] Mandibular Cortical Bone Index Using Multi-Slice and Cone-Beam Computed Tomography
    Naitoh, Munetaka
    Takada, Shoko Tamaki
    Watanabe, Hirofumi
    Hayashi, Hisashi
    Miyamae, Shin
    Ariji, Eiichiro
    JOURNAL OF HARD TISSUE BIOLOGY, 2016, 25 (03) : 241 - 246
  • [35] A generalized helical reconstruction algorithm for multi-slice CT
    Hsieh, J
    Toth, TL
    Simoni, P
    Grekowicz, B
    Slack, CC
    Seidenschnur, GE
    RADIOLOGY, 2001, 221 : 217 - 217
  • [36] Accuracy assessment of prototypes produced using multi-slice and cone-beam computed tomography
    Primo, B. T.
    Presotto, A. C.
    de Oliveira, H. W.
    Gassen, H. T.
    Miguens, S. A. Q., Jr.
    Silva, A. N., Jr.
    Hernandez, P. A. G.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 41 (10) : 1291 - 1295
  • [37] A comparative study for spatial resolution and subjective image characteristics of a multi-slice CT and a cone-beam CT for dental use
    Watanabe, Hiroshi
    Honda, Eiichi
    Tetsumura, Akemi
    Kurabayashi, Tohru
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 77 (03) : 397 - 402
  • [38] Optimization-based reconstruction for multi-displaced single-slice spiral CT
    Zou, Xiaobing
    Xiao, Li
    Wei, Pengcheng
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2022,
  • [39] A multi-slice helical CT reconstruction with generalized weighting
    Hsieh, J
    Toth, T
    Simoni, P
    Slack, C
    Grekowicz, B
    Seidenschnur, G
    Wang, S
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1732 - 1736
  • [40] Optimization-based reconstruction for multi-displaced single-slice spiral CT
    Zou, Xiaobing
    Xiao, Li
    Wei, Pengcheng
    International Journal of Advanced Manufacturing Technology, 2022,