Screening Radiation Exposure for Quality Assurance

被引:1
作者
Bastiao Silva, Luis A. [1 ]
Ribeiro, Luis S. [1 ]
Santos, Milton [1 ]
Costa, Carlos [1 ]
Oliveira, Jose Luis [1 ]
机构
[1] Univ Aveiro, DETI, IEETA, Aveiro, Portugal
来源
E-HEALTH - FOR CONTINUITY OF CARE | 2014年 / 205卷
关键词
Patient Dosimetry; Quality Assurance; Medical Exposure Directive; DICOM; IHE REM; CANCER; RISK;
D O I
10.3233/978-1-61499-432-9-622
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Quality assurance for planned radiation exposure situations (e.g. Digital Radiography, Computed Tomography or Radio Fluoroscopic studies) requires the application of examination-specific scans protocols. These are tailored to patient age or size, body region and clinical indication for ensuring that the dose applied to each patient is as low as reasonably achievable for the clinical purpose of the image acquisition (ALARA principle). The European legal framework - 2013/59/EURATOM - points that health authorities will be more pervasive on inspecting the dosimetry applied to patients. This paper discusses these legal alterations and presents an interoperable distributed system for dose monitoring, which is compliant with legal procedures and the IHE Radiation Exposure Monitoring profile (REM). The system combines the most representative stakeholders affected and directly interested in the patient radiological protection: patients, radiologists, practitioners, health authorities, and ethics committee. The system is capable of gathering, in real-time, dose information applied to the patient and storing it in a regional or national wide dose registry. The paper addresses which information should such systems hold and which should be accessed, from each stakeholder perspective. Furthermore, the system may detect irregular dose patterns, which could indicate dose abuses, and signal those findings to the appropriate stakeholders.
引用
收藏
页码:622 / 626
页数:5
相关论文
共 13 条
[1]  
Bartal G, 2013, CARDIOVASCULAR INTER, P1
[2]   RISK OF BREAST-CANCER FOLLOWING LOW-DOSE RADIATION EXPOSURE [J].
BOICE, JD ;
LAND, CE ;
SHORE, RE ;
NORMAN, JE ;
TOKUNAGA, M .
RADIOLOGY, 1979, 131 (03) :589-597
[3]   Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323
[4]  
Euratom, 1997, 1997 43 HLTH PROT IN
[5]  
Eurotom, 2013, 2013 59 LAYING BAS S
[6]  
Finkelstein MM, 1998, CAN J CARDIOL, V14, P1385
[7]   Informatics in Radiology Efficiency Metrics for Imaging Device Productivity [J].
Hu, Mengqi ;
Pavlicek, William ;
Liu, Patrick T. ;
Zhang, Muhong ;
Langer, Steve G. ;
Wang, Shanshan ;
Place, Vicki ;
Miranda, Rafael ;
Wu, Teresa Tong .
RADIOGRAPHICS, 2011, 31 (02) :603-U349
[8]  
IHE, 2008, RAD EXP MON REM INT, P65
[9]  
Luis Bastiao Silva MS, 2013, 27 COMP ASS RAD SURG
[10]   Brain tumours among interventional cardiologists: a cause for alarm? Report of four new cases from two cities and a review of the literature [J].
Roguin, Ariel ;
Goldstein, Jacob ;
Bar, Olivier .
EUROINTERVENTION, 2012, 7 (09) :1081-1086