Numerical investigation of convection heat transfer in solar air heater with semi-circular shape transverse rib

被引:5
作者
Assaye, Mebratu [1 ]
Biadgelegn, Muluken [1 ]
Fekadu, Birlie [1 ]
机构
[1] Debre Markos Univ, Sch Mech & Ind Engn, Debre Markos, Ethiopia
关键词
solar air heater; Nusselt number; friction factor; semi-circular rib; CFD; COMPUTATIONAL FLUID-DYNAMICS; TRANSFER ENHANCEMENT; CFD ANALYSIS; FRICTION CHARACTERISTICS; TRANSFER AUGMENTATION; ARTIFICIAL ROUGHNESS; FLOW CHARACTERISTICS; RECTANGULAR DUCT; CHANNEL; GAP;
D O I
10.1080/23311916.2022.2106930
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Heat transfer devices have been employed in a wide range of industrial and home applications for heat conversion and recovery. Artificial roughness in the shape of repetitive ribs on a surface is a useful approach for improving heat transfer rates. The heat transfer and fluid flow properties of fully developed turbulent flow in a rectangular duct with repeated transverse semi-circular sectioned rib roughness on the absorber plate were investigated. A numerical solution has been done using fluent ANSYS 16 commercial software, and validation of result was carried out with Dittus-Boelter correlation. The numerical investigation of the thermal performance of a solar air heater was carried out at relative roughness pitch (between 7.14 and 17.86), Reynolds number (3800 and 18,000), heat flux (1000 W/m2), and constant relative roughness height (e/D = 0.042). For the analyzed range of parameters, it was found that the semi-circular transverse rib roughened duct with P/e = 10.71 and e/D = 0.042 provides the optimum thermo-hydraulic performance parameter. Within this optimum configuration, the maximum thermo-hydraulic performance parameter has been found to be 1.7328 at Reynolds number 15,000.
引用
收藏
页数:14
相关论文
共 30 条
[1]   Numerical analysis on solar air collector provided with artificial square shaped roughness for indirect type solar dryer [J].
Abhay, L. ;
Chandramohan, V. P. ;
Raju, V. R. K. .
JOURNAL OF CLEANER PRODUCTION, 2018, 190 :353-367
[2]   Experimental investigation on heat-transfer enhancement due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar air heater [J].
Aharwal, K. R. ;
Gandhi, B. K. ;
Saini, J. S. .
RENEWABLE ENERGY, 2008, 33 (04) :585-596
[3]   Experimental and CFD analysis of plain and dimples tube at application of solar water heater [J].
Arun, M. ;
Barik, Debabrata ;
Sridhar, K. P. ;
Vignesh, G. .
MATERIALS TODAY-PROCEEDINGS, 2021, 42 :804-809
[4]   CFD based analysis of heat transfer enhancement in solar air heater provided with transverse rectangular ribs [J].
Boulemtafes-Boukadoum, A. ;
Benzaoui, A. .
TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY (TMREES14 - EUMISD), 2014, 50 :761-772
[5]   Heat transfer and pressure drop in rectangular channel with compound roughness of V-shaped ribs and deepened scales [J].
Chang, S. W. ;
Liou, T. -M. ;
Chiang, K. F. ;
Hong, G. F. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2008, 51 (3-4) :457-468
[6]   Analysis of heat transfer augmentation and flow characteristics due to rib roughness over absorber plate of a solar air heater [J].
Chaube, A ;
Sahoo, PK ;
Solanki, SC .
RENEWABLE ENERGY, 2006, 31 (03) :317-331
[7]   Numerical analysis of roughness effect on microtube heat transfer [J].
Croce, G ;
D'Agaro, P .
SUPERLATTICES AND MICROSTRUCTURES, 2004, 35 (3-6) :601-616
[8]  
F. P. Incropera, 2007, Fundamentals of Heat and Mass Transfer, V6th
[9]   The influence of artificial roughness shape on heat transfer enhancement: Corrugated tubes, dimpled tubes and wire coils [J].
Garcia, A. ;
Solano, J. P. ;
Vicente, P. G. ;
Viedma, A. .
APPLIED THERMAL ENGINEERING, 2012, 35 :196-201
[10]   Experimental and CFD investigation of convection heat transfer in solar air heater with reverse L-shaped ribs [J].
Gawande, Vipin B. ;
Dhoble, A. S. ;
Zodpe, D. B. ;
Chamoli, Sunil .
SOLAR ENERGY, 2016, 131 :275-295