Microneedle Insertion into Visco-Hyperelastic Model for Skin for Healthcare Application

被引:3
|
作者
Widianto, Davira P. [1 ]
Stewart, Benjamin G. [1 ]
Mena-Lapaix, Juan L. [2 ]
Shafer, Richard H. [3 ]
Burns, Andrew [4 ]
Prausnitz, Mark R. [2 ]
Alizadeh, Azar [4 ]
Sitaraman, Suresh K. [1 ]
机构
[1] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Sch Chem & Biomol Engn, Atlanta, GA 30332 USA
[3] Georgia Inst Technol, Inst Elect & Nanotechnol, Flexible Wearable Elect Adv Res Program, Atlanta, GA 30332 USA
[4] GE Res, Niskayuna, NY USA
来源
IEEE 71ST ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC 2021) | 2021年
关键词
microneedle; cohesive zone modeling; finite-element analysis; nonlinear constitutive behavior; PARAMETERS; BEHAVIOR; FAILURE;
D O I
10.1109/ECTC32696.2021.00236
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recently, microneedle patches have been explored for extracting interstitial fluid with the goal of extracting temporally relevant, clinical-grade information for human health monitoring. As compared to traditional hypodermic needles, the sub-millimeter scale of microneedles allows for the creation of micropores providing access into human skin interstitial fluid while minimizing interactions with blood vessels and nerves, leading to painless insertion with little to no bleeding. An essential sub-component is the actuator, responsible for driving the microneedle into the skin with a precise force and velocity to ensure reliable insertion. Reliability, in this case, consists of two criteria: the ability of the microneedle to 1) penetrate the skin, and 2) withstand penetration forces without mechanical failure. Evaluation of these criteria requires a thorough understanding of the non-linear, time-dependent interactions between the microneedle and the skin during insertion, including rupture and tearing of the skin on the micron scale, and the resultant stresses on the microneedle. To this end, a comprehensive finite-element model was developed to simulate the microneedle insertion process. This analysis yielded a prediction of complete microneedle insertion without failure of the microneedle and an estimated insertion force of 0.055 N per microneedle, well within the capability of the actuator system considered. This insertion force was validated using experimental data obtained through microneedle insertion in whole skin samples. The model was then used to perform several parametric studies, yielding valuable insights for possible future design improvements.
引用
收藏
页码:1481 / 1489
页数:9
相关论文
共 50 条
  • [21] Effect of rubber properties on the performance of Visco-Hyperelastic Damper (VHD)
    Modhej, Ahmad
    Zahrai, Seyed Mehdi
    Moghadam, Abdolreza S.
    STRUCTURES, 2023, 58
  • [22] A visco-hyperelastic constitutive approach for modeling polyvinyl alcohol sponge
    Karimi, Alireza
    Navidbakhsh, Mahdi
    Beigzadeh, Borhan
    TISSUE & CELL, 2014, 46 (01) : 97 - 102
  • [23] Developing a visco-hyperelastic material model for 3D finite deformation of elastomers
    Fahimi, Shayan
    Baghani, Mostafa
    Zakerzadeh, Mohammad-Reza
    Eskandari, AmirHossein
    FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2018, 140 : 1 - 10
  • [24] A COMPARISON OF VISCO-HYPOELASTIC AND VISCO-HYPERELASTIC MODEL TO PREDICT THE ELASTIC STRAIN ENERGY FOR ARTICULAR CARTILAGE OF KNEE JOINT
    Gonzalez-Navarrete, Roberto
    Vidal-Lesso, Agustin
    Plascencia Mora, Hector
    Ulises Huerta-Jacobo, Xavier
    PROCEEDINGS OF ASME 2021 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE2021), VOL 5, 2021,
  • [25] A 3-D Visco-Hyperelastic Constitutive Model for Rubber with Damage for Finite Element Simulation
    Tabiei, Ala
    Khambati, Suraush
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2015, 105 (01): : 25 - 45
  • [26] Characterization of perfused and sectioned liver tissue in a full indentation cycle using a visco-hyperelastic model
    Li, Ling
    Maccabi, Ashkan
    Abiri, Ahmad
    Juo, Yen-Yi
    Zhang, Wenyang
    Chang, Yi-Jui
    Saddik, George N.
    Jin, Lihua
    Grundfest, Warren S.
    Dutson, Erik P.
    Eldredge, Jeff D.
    Benharash, Peyman
    Candler, Robert N.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 90 : 591 - 603
  • [27] Visco-Hyperelastic Model with Damage for Simulating Cyclic Thermoplastic Elastomers Behavior Applied to an Industrial Component
    Tobajas, Rafael
    Elduque, Daniel
    Ibarz, Elena
    Javierre, Carlos
    Canteli, Alfonso F.
    Gracia, Luis
    POLYMERS, 2018, 10 (06)
  • [28] Adaptive affine homogenization method for Visco-hyperelastic composites with imperfect interface
    Kim, Youngsoo
    Jung, Jiyoung
    Lee, Sangryun
    Doghri, Issam
    Ryu, Seunghwa
    APPLIED MATHEMATICAL MODELLING, 2022, 107 : 72 - 84
  • [29] A visco-hyperelastic model of brain tissue incorporating both tension/compression asymmetry and volume compressibility
    Zhu, Zhongmeng
    Jiang, Chengkai
    Jiang, Han
    ACTA MECHANICA, 2019, 230 (06) : 2125 - 2135
  • [30] A General Visco-Hyperelastic Model for Dielectric Elastomers and Its Efficient Simulation Based on Complex Frequency Representation
    Wang, Yongquan
    Chen, Hualing
    Wang, Yanjie
    Li, Dichen
    INTERNATIONAL JOURNAL OF APPLIED MECHANICS, 2015, 7 (01)